The NO-COMPROMISE UPS HX
March 29, 2021
Energy Management System
April 2, 2021
Show all

PORTABLE TEST & MEASUREMENT INSTRUMENTS

Category:
Description

About Us

Atandra Energy Pvt. Ltd. is a Chennai based company built on a platform of over 30 years experience in the area of Power & Energy Management.

Leading Brand – KRYKARD

We offer solutions to industrial and commercial establishments under our popular brand KRYKARD. with over 4,00,000 installations of Power Conditioners and over 1,50,000 installations of Portable and Panel Load Managers, KRYKARD is one of the leading brands in the area of Power Conditioning & Energy Management.

ATEST is our new brand for Test & Measurement products to meet the growing expectations of industry for performance oriented T&M products that meet the expanding needs and have multilayered offering of specifications, performance and price. The ATEST range of T&M products meet all key applications and needs of industry, auditors and OEMs.

Our Facilities

We have the following in-house facilities:

  • An ISO 9001:2015 certified factory
  • R&D department for Power Electronics and Electro-magnetics.
  • A Software Development department to design, develop and customise Energy Management Software.

With around 300 employees and a network of branches across the country, we are well equipped to reach and service the needs of our customers.

Our Foreign Principals:

Certain niche and high-end models of our range are imported from our foreign principals. Atandra markets these products and provides technical, application and service support to these products in India.

Chauvin Arnoux

Founded in Paris, in 1893, CHAUVIN ARNOUX is a major player in the measurement market in France and internationally.

Metrix is a group of Chauvin Arnoux- specialized by manufacturing industrial, laboratory and educational instrumentation.

Dranetz

For more than 50 years, Dranetz has been the leading provider of intelligent monitoring solutions for electrical demand a energy and power quality.

Clamp Meter

TRMS 100A AC Leakage Clamp Meter ATEST LC 100

Salient Features:
  • TRMS 100A Leakage Clamp Meter
  • 10μA resolution on 60mA range
  • Maximum Jaw opening: ø 28 mm
  • 9999 count digital display
  • Autoranging
  • Auto Power off
  • Max function
  • Data Hold function
  • Auto Zero
  • Safety standard CAT III 600V

RMS Measurements:

Parameter Range Accuracy %
ACMA 60mA/600mA 2
AC Current 10A/100A 2
DC Voltage 600v 1
AC Voltage 600v 1.2
Frequency 1000Hz 0.1
Resistance 1000Ω 1

100A Leakage Current Clamp Meter ATEST LC 102

Salient Features:
  • True RMS 100A Leakage Clamp Meter
  • 1μA resolution
  • Maximum Jaw opening: ø 40mm
  • 6000 Count digital large scale display
  • Auto ranging
  • Analog Bargraph
  • Hold / Auto-Hold indications, Register peaks
  • Comparison with tolerance (3 fixed values: 0.25 mA; 0.5 mA; 3.5 mA)
  • Low Pass Filter with high stability
  • Auto Power off (Disable)
  • 4 feet Drop Proof
  • Safety standard CAT III 300V
Parameter Range Accuracy %
AC Current 6mA/100A 1

20A TRMS Milli Amps AC/DC Clamp Meter ATEST C 20TD

Salient Features:
  • True RMS measurement on 20A
  • 0.1 mA Current resolution
  • Maximum Jaw opening: ø 23 mm
  • 5000 Count digital large scale display
  • Autoranging
  • Backlight function
  • Min/Max measurement function
  • Data Hold function
  • Zero function
  • Auto Power off
  • Safety standard CAT III 300V
Parameter Range Accuracy %
DC Current 300mA/3000mA/10A 1
AC Current 300mA/3000mA/20A 1
DC Voltage 50V/300V 1
AC Voltage 50V/300V 1
Resistance 500Ω/5KΩ/50KΩ/500KΩ 1
Resistance <1000Ω

400A AC Clamp Meter ATEST C 400

Salient Features:
  • Current measurement upto 400A
  • 0.01A resolution
  • Maximum Jaw opening: ø 25.4 mm
  • 3999 count display digits
  • AC/DC Voltage measurement up to 600V
  • Auto Switch between AC and DC Voltage
  • Auto Switch between capacitance, diode Test, continuity, and resistance
  • Non-Contact Voltage detection)
  • Safety standard CAT III 600V

 

Parameter Range Accuracy %
AC Current 40A/400A 1.9
AC Voltage 400V/600V 1.2
DC Voltage 400V/600V 1
Resistance 400Ω 1
Continuity <25Ω

400A TRMS AC Clamp Meter ATEST C 410T

Salient Features:
  • True RMS reading on 400A
  • Maximum Jaw opening: ø 27 mm
  • 10,000 count LCD Display
  • Auto sensing
  • Continuity beeper
  • Diode test
  • Smart Data Hold
  • Shock proof from 4 feet Drops
  • Non-Contact Voltage detection)
  • Standard full-sleeve safety test leads
  • Carrying case included
  • Safety standard CAT III 600V
Parameter Range Accuracy %
AC Current 40A/400A 1.9
AC Voltage 1000V 1.2
DC Voltage 1000V 0.3
Resistance 10KΩ 0.9
Continuity < 25Ω

400A TRMS AC/DC Clamp Meter ATEST C 420TD

Salient Features:
  • True RMS reading on 400A
  • Maximum Jaw opening: ø 27 mm
  • 4000 count LCD Display
  • Continuity beeper
  • Diode test
  • Smart Data Hold
  • On touched DCA Zeroing
  • Shock proof from 4 feet Drops
  • standard full-sleeve safety test leads
  • Carrying case included
  • Safety standard CAT III 600V
Parameter Range Accuracy %
DC Current 40A/ 400A 1.5
AC Current 40A/ 400A 1.5
DC Voltage 400V/ 600V 0.7
AC Voltage 400V/ 600V 0.9
Resistance 400Ω~40MΩ 0.9
Frequency 40Hz~40KHz 0.3
Diode 3.1V max
Continuity <50Ω, 2KHz tone buzzer

600A AC Clamp Meter ATEST C 600

Salient Features:
  • RMS measurement on 600A
  • 0.01A resolution
  • Maximum Jaw opening: ø 25.4 mm
  • 5999 count LCD display
  • AC/DC Voltage measurement Up to 600V
  • AC Current measurement Up to 600A
  • Auto Switch between AC and DC Voltage
  • Auto Switch between capacitance, diode Test, continuity, and resistance
  • Non-Contact Voltage detection
  • Safety standard CAT III 600V
Parameter Range Accuracy %
AC Current 60A/600A 1.9
AC/DC Voltage 6V/60V/600V 1
Resistance 600Ω~6MΩ 1.2
Capacitance 6nF/600uF 3
Frequency(A) 6KHz/10KHz 0.2
Frequency(V) 6KHz/60KHz/100KHz 0.2
Diode 0 ~ 1.2V
Continuity < 30Ω

600A TRMS AC Clamp Meter ATEST C 610T

Salient Features:
  • True RMS reading on 600A
  • 0.1A resolution
  • Maximum Jaw opening: ø 34 mm
  • 4000 count LCD display
  • Autoranging
  • Diode Test
  • Smart Data Hold
  • Zeroing key
  • Max Hold
  • Auto Power off (can be disabled)
  • 4 feet drop proof
  • Hand Guard & stream line designed
  • Safety standard CAT III 600V
Parameter Range Accuracy %
AC Current 400A, 600A 1.9
DC Voltage 400V, 600V 0.9
AC Voltage 400V, 600V 1.5
Resistance 400Ω 1
Frequency 4KHz, 10KH 0.1
Diode 3.3V max
Continuity <30Ω

600A TRMS AC/DC Clamp Meter ATEST C 620TD

Salient Features:
  • True RMS reading on 600A
  • 10mA resolution
  • Maximum Jaw opening: ø 36 mm
  • 6000 count LCD display
  • Autoranging
  • Diode Test
  • Smart data Hold
  • Zeroing key
  • Max Hold
  • Auto Power off (can be disabled)
  • 4 feet Drop Proof
  • Hand Guard & stream line designed
  • Safety standard CAT III 600V
Parameter Range Accuracy %
DC Current 60A, 600A 1.5
AC Current 60A, 600A 1.9
DC Voltage 600V 0.7
AC Voltage 600V 1.5
Resistance 600Ω~40MΩ 0.9
Frequency 100 Hz … 50 kHz 1
Diode 1.500V 1.5
Continuity <20Ω, 2.7KHz tone buzzer

1000A TRMS AC Clamp Meter ATEST C 1000T

Salient Features:
  • True RMS measurement on 1000A
  • 0.1A resolution
  • Maximum Jaw opening: ø 40 mm
  • 6000 Count large display
  • Data Hold function
  • Min/ Max function
  • Auto Power off
  • Autoranging
  • Safety standard CAT III 600V
Parameter Range Accuracy %
AC Current 600A/1000A 1.9
AC Voltage 6V/60V/600V 1.2
DC Voltage 6V/60V/600V 1
Resistance 600Ω/6KΩ/600KΩ 1

1000A TRMS AC/DC Digital Clamp Meter ATEST C 1010TD

Salient Features:
  • True RMS reading on 1000A
  • 0.1A resolution
  • Maximum Jaw opening: ø 51 mm
  • 4000 Count large display
  • Backlit, large scale display
  • Analog Bargraph
  • Excellent residual magnetism performance
  • Continuity Beeper
  • Display Hold, Peak Hold (10ms)
  • DCA Zeroing key
  • Min/ Max function
  • Frequency Counter
  • Safety standard CAT IV 600V
Parameter Range Accuracy %
AC Current 400A, 1000A 1.9
DC Current 400A, 1000A 1
AC Voltage 400V, 750V 1
DC Voltage 400V, 1000V 1
Resistance 400Ω 1
Frequency 20Hz~400Hz 0.1
Diode 3V max
Continuity <30Ω, 2KHz tone buzzer

1000A TRMS AC/DC Digital Clamp Meter ATEST C 1020TD

Salient Features:
  • True RMS reading on AC and AC+DC
  • 0.01A resolution
  • Maximum Jaw opening: ø 45 mm
  • 10,000 Count large display
  • Power and Power factor measurement
  • Inrush Current
  • Low Pass Filter
  • Excellent residual magnetism performance
  • Continuity Beeper
  • Display Hold, Peak Hold (10ms)
  • DCA Zeroing key
  • Min/Max function
  • Frequency Counter
  • Safety standard CAT IV 600V
Parameter Range Accuracy %
AC Current 100A, 1000A 1.5
DC Current 100A, 1000A 1.5
ACA Via SFLEX 0.1A~3000A
AC Voltage 100V, 1000V 1
DC Voltage 100V, 1000V 1
AC+DC Voltage 100V,1000V 1
Resistance 100KΩ 1
Watt 10KW~1MW 2.5
THD 0.1%~100% 3
Harmonics 0.1%~100% 0.1
Frequency 20.0Hz~10KHz 0.5

Power and Harmonic Clamps F205, F407, F607

Salient Features:
  • True RMS reading on AC mode
  • Current: 2000 A AC / 3000 A DC
  • AC and DC Voltage up to 1000 V
  • Clamp Dia 34mm, 48mm, 60,mm
  • Backlit, large scale display
  • TrueInrush Current measurement
  • Power values (W, var, VA, PF) and Harmonics (THDf, THDr)
  • Min/Max, Peak+, Peak-
  • Relative (ΔX) and differential (ΔX/X) measurements
  • Safety standard CAT IV 1000 V
Parameter Range
Models F205 F407 F607
Clamp Dia 34mm 48mm 60mm
Type [AC, AC+DC]/DC
Voltage 0.15 to 1,000 V
Current 0.25 to 600 A 0.25 to 1,000 A 0.25 to 3,000 A
Resistance 60KΩ 100kΩ 100kΩ
Diode Test Yes No No
THDf / THDr Yes
Power Yes
Continuity Yes
Recording NO Yes,Bluetooth Yes,Bluetooth

Earth Clamps and Loop Tester C.A 6416, C.A 6417

Salient Features:
  • Large measurement range: 1500 Ω / 500 µH / 40A
  • Alarms on Ω, A and V
  • Automatic Pre-Hold mode when the Clamp is opened
  • 300 storage locations(C.A 6416)
  • Real-time clock for time/date-stamping of measurements
  • Automatic calibration of jaw opening distance at start-up
  • Buzzer and automatic power-off
  • 2000 storage locations(C.A 6417)
  • Buzzer and automatic power-off
  • Bluetooth communication(C.A 6417)
  • GTC data transfer software (C.A 6417)
  • Safety standard CAT IV 600V
Parameter Range
Display Backlit LCD
Loop ohmmeter 0.010 to 1500
measurement
Frequency
2083 Hz
Transposition
frequency
50, 60, 128 or 2,083 Hz
Loop inductance 10μH to 500μH
Ground Voltage 0.1V to 75V
Ammeter 0.200mA to 39.99A
Others Alarms,Buzzer,Hold,Automatic power- off
Weight 55 x 95 x 262 mm/ 935gm

Voltage Tester ATEST VT 10

Salient Features:
  • 750V ACV/DCV
  • Integrated single pole test for phase detection
  • Rotary field indication
  • Dual display for ACV measuring with Frequency
  • 2 pole tester with 2000 count digital display
  • Ultra bright white LED torch
  • Self Test
  • IP65 water-jet and dust-tight protection for outdoor use
  • Safety standard CAT IV 600V
Parameter Range Accuracy %
DC Voltage 2V ~ 750V 1
AC Voltage 1V ~ 750V 1.3
Resistance 0Ω ~ 2000Ω 2
Frequency Counter 30Hz ~ 999Hz 0.3
Diode Test 0.3V ~ 0.9V 0.9
Single Phase Test V 100V ~ 750V AC
Single Phase Test Hz 45Hz ~ 65Hz
Rotary Field
Indication V
100V ~ 750V AC
Rotary Field
Indication Hz
50Hz ~ 60Hz

Digital Multimeter

Pocket Type Digital Multimeter ATEST M nano 1

Salient Features:
  • 600V ACV/DCV
  • RMS measurement
  • 4000 count large scale digital display
  • Auto ranging and manual Selection
  • Relative Mode on Capacitance
  • Auto Power off
  • Data Hold
  • Shock proof from 4 feet drops
  • Compact design on small size
  • Integral Safety test leads
  • Deluxe Carrying wallet Included
  • Safety standard CAT II 600V
Parameter Range Accuracy %
DC Voltage 400.0mV ~ 600V 0.6
AC Voltage 400.0mV ~ 600V 0.9
Resistance 400.0Ω ~ 40.00MΩ 0.9
Capacitance 50nF ~ 100uF 2.9
Frequency Counter 5Hz ~ 5MHz 0.3
Duty Cycle 0.1% ~ 99.9% 0.3
Diode Test Open circuit Voltage: 1.5V
Continuity Beeper <30 Ω , 2KHz tone buzzer

Pocket size Digital Multimeter ATEST M 2100

Salient Features:
  • 600V ACV/DCV
  • True RMS on ACV
  • 6000 count digital large display
  • Peak Hold for capture peak readings
  • Relative function
  • Auto Power off (Can be disabled)
  • Non-Contact Voltage detection
  • Continuity with beeper and display
  • Battery capacity indication in segments
  • Pocket size stream line design
  • Optional holster with probe holder, tilt stand and magnetic sticker
  • Safety standard CAT III 600V
Parameter Range Accuracy %
DC Voltage 6V, 60V, 600V 0.5
AC Voltage 6V, 60V, 600V 1
DCmV 600mV 0.5
Resistance 600Ω~40MΩ 0.5
Capacitance 50nF~1000μF 2
Frequency Counter 100Hz~50KHz 0.1
Diode Test 1.500V 1
Continuity Beeper <30Ω, 2.7KHz tone buzzer

Pocket size Digital Multimeter ATEST M 2102

Salient Features:
  • 600V ACV/DCV
  • True RMS on ACV and ACA
  • 6000 count digital large display
  • Auto Ranging
  • Relative function
  • Non-Contact Voltage detection
  • Continuity with beeper and display
  • DC µA function
  • High Energy Fuse
  • Pocket size stream line design
  • Safety standard CAT III 600V
Parameter Range Accuracy %
DC Voltage 6V, 60V, 600V 0.5
AC Voltage 6V, 60V, 600V 1
DCmV 600mV 0.5
ACA, DCA 6A, 10A 1.5
DCμA 400µA, 4000µA 0.9
Resistance 600Ω~40MΩ 0.5
Capacitance 50nF~1000μF 2
Frequency Counter 100Hz~50KHz 0.1
Diode Test 1.500V 1

Pocket size Digital Multimeter ATEST M 2104

Salient Features:
  • 600V ACV/DCV
  • True RMS on ACV & ACA
  • 6000 count digital large display
  • DC µA function
  • Peak Hold for capture peak readings
  • Relative function
  • Non-Contact Voltage detection
  • Continuity with beeper and display
  • High Energy Fuse
  • Pocket size stream line design
  • Safety standard CAT III 600V
Parameter Range Accuracy %
DC Voltage 6V, 60V, 600V 0.5
AC Voltage 6V, 60V, 600V 1
DCmV 600mV 0.5
ACA, DCA 6A, 10A 1.5
DCμA 400µA, 4000µA 0.9
Resistance 600Ω~40MΩ 0.5
Capacitance 50nF~1000μF 2
Frequency Counter 100Hz~50KHz 0.1
Temperature -40°C ~ 400°C 1
Diode Test 1.500V 1

TRMS Digital Multimeter ATEST M 2300

Salient Features:
  • 1000V ACV/DCV
  • True RMS reading on AC mode
  • 6000 count large scale digital display
  • Autoranging and manual selection
  • Smart Data Hold, NCV
  • PEAK Hold/Relative function key
  • Beep Guard
  • Shock proof from 4 feet drops
  • Comfortable holster with probe holder and tilt stand
  • Safety standard CAT III 600V
Parameter Range Accuracy %
DC Voltage 60mV ~ 1000V 0.5
AC Voltage 60mV ~ 1000V 1
DC Current 6A/10A 1
AC Current 6A/10A 1.5
Resistance 600Ω ~ 40MΩ 0.8
Capacitance 10nF ~ 10mF 1.9
Frequency Counter 6kHz ~ 100kHz 0.1
Diode Test 1.8V
Continuity Beeper <30Ω, 2kHz tone Buzzer

TRMS Digital Multimeter ATEST M 2302

Salient Features:
  • 1000V ACV/DCV
  • True RMS reading on AC mode
  • 6000 count large scale digital display
  • Autoranging and manual selection
  • Smart Data Hold
  • Non Contact Voltage detection
  • PEAK Hold/Relative function key
  • Beep Guard
  • Shock proof from 4 feet drops
  • Comfortable holster with probe holder and tilt stand
  • Safety standard CAT III 600V
Parameter Range Accuracy %
DC Voltage 60mV ~ 1000V 0.5
AC Voltage 60mV ~ 1000V 1
DC Current 6A/10A 1
AC Current 6A/10A 1.5
Resistance 600Ω ~ 40MΩ 0.8
Capacitance 10nF ~ 10mF 1.9
Frequency Counter 6kHz ~ 100kHz 0.1
Temperature – 40°C ~ 400°C 1
Diode Test 1.8V
Continuity Beeper <30Ω, 2kHz tone Buzzer

TRMS Digital Multimeter ATEST M6 2200

Salient Features:
  • 1000V ACV/DCV
  • True RMS measurements on ACV
  • 6000 count digital and 60 segments analog display
  • LoZ for prevent false reading from ghost Voltage
  • Peak Hold for capture peak readings
  • Relative function
  • Non-Contact Voltage detection
  • Holster with built in magnetic sticker
  • Continuity with beeper and display
  • Battery Capacity indication in segments
  • Safety standard CAT IV 600V
Parameter Range Accuracy %
DC Voltage 600mV, 1000V 0.5
AC Voltage 600mV, 1000V 1
Auto-V LoZ 600V, 1000V 2
Resistance 600Ω~40.00MΩ 0.9
Capacitance 1.000μF~10.00mF 1.9
Frequency Counter 100Hz~100KH 0.1
Diode Test 1.500V

TRMS Digital Multimeter ATEST M6 2202

Salient Features:
  • 1000V ACV/DCV
  • True RMS measurements on ACV
  • 6000 count digital and 60 segments analog display
  • μA measurement on both AC and DC
  • LoZ for prevent false reading from ghost Voltage
  • Peak Hold for capture peak readings
  • Relative function
  • Non-Contact Voltage detection
  • Holster with built in magnetic sticker
  • Continuity with beeper and display
  • Battery Capacity indication in segments
  • Safety standard CAT IV 600V
Parameter Range Accuracy %
DC Voltage 600mV, 1000V 0.5
AC Voltage 600mV, 1000V 1
Auto-V LoZ 600V, 1000V 2
DC μA 600μA 2
AC μA 600μA 1.5
Resistance 600Ω~40MΩ 0.9
Capacitance 1μF~10mF 1.9
Frequency Counter 100Hz~100KHz 0.1
Temperature -40°C~400°C 1
Diode Test 1.500V

TRMS Digital Multimeter ATEST M6 2204

Salient Features:
  • 1000V ACV/DCV
  • True RMS measurements on ACV/ACA
  • 6000 count digital and 60 segments analog display
  • LoZ for prevent false reading from ghost Voltage
  • Non-Contact Voltage detection
  • Holster with built in magnetic sticker
  • Continuity with beeper and display
  • 11A/1000V High Energy Fuse
  • Battery Capacity indication in segments
  • Safety standard CAT IV 600V
Parameter Range Accuracy %
DC Voltage 600mV, 1000V 0.5
AC Voltage 600mV, 1000V 1
Auto-V LoZ 600V, 1000V 2
DC Current 6A, 10A 1
AC Current 6A, 10A 1.5
Resistance 600Ω~40MΩ 0.9
Capacitance 1μF~10mF 1.9
Frequency Counter 100Hz~100KHz 0.1
Diode Test 1.500V

AC+DC TRMS Industrial Multimeter ATEST MH 2502

Salient Features:
  • 1000V ACV/DCV
  • True RMS measurements on ACV/ACA,
  • (AC+DC)V and (AC+DC)mV measurements
  • (AC+DC)A and (AC+DC)mA measurements
  • 6000 count digital and 62 segments analog display
  • LoZ for prevent false reading from ghost Voltage
  • Non-Contact Voltage detection
  • 11A/1000V & 400mA/1000V High Energy Fuses
  • Shock proof from 4 feet drops
  • Safety standard CAT IV 600V

 

Parameter Range Accuracy %
DC Voltage 600mV, 1000V 0.08
AC Voltage 60mV, 1000V 0.8
Auto V-LoZ 600V, 1000V 0.8
DC Current 60mA, 10A 0.8
AC Current 60mA, 10A 1.2
Resistance 600Ω~40MΩ 0.8
Capacitance 1μF~10mF 1.2
Frequency Counter 100Hz ~ 100KHz 0.1
Temperature -40°C ~ 400°C 1
Diode Test 1.8V max

High performance Digital Multimeter ATEST MH 2542

Salient Features:
  • 1000V ACV/DCV
  • True RMS reading on AC and AC+DC mode
  • 40,000/4000 count extra large digital display. 43 segments analog bar graph
  • Auto Backlit, Dual display
  • Navigator key drive
  • High Frequency Rejection (HFR)
  • Relative/% function
  • Store/Recall memories
  • dBm/dB measurement
  • 20,000 records data logging capacity
  • USB interface with Software included
  • Safety standard CAT IV 600V
Parameter Range Accuracy %
DC Voltage 40mV to 1000V 0.03
ACV & (AC+DC)V 40mV to 1000V 0.7
DC Current 40mA to 10A 0.2
ACA & (AC+DC)A 40mA to 10A 0.8
Resistance 400Ω to 40MΩ 0.2
Capacitance 4nF to 40mF 0.9
Frequency Counter 40Hz to 4MHz 0.002
Duty Cycle 20% to 80% 0.1
Temperature -200℃ to 1200℃
Diode Test Open Circuit Voltage:±3V

High performance Digital Multimeter ATEST MH 2540

Salient Features:
  • 1000V ACV/DCV
  • True RMS reading on AC and AC+DC mode
  • 1,00,000/10,000 count extra large digital display. 43 segments analog bar graph
  • Backlit, Dual display
  • High Frequency Rejection (HFR)
  • Min/Max/Avg
  • Relative/% function
  • Auto Hold/Peak Hold
  • Store/Recall memories
  • dBm/dB measurement
  • 20,000 records data logging capacity
  • USB interface with Software included
  • Safety standard CAT IV 600V
Parameter Range Accuracy %
DC Voltage 40mV to 1000V 0.015
ACV & (AC+DC)V 40mV to 1000V 0.7
DC Current 40mA to 10A 0.2
ACA & (AC+DC)A 40mA to 10A 0.8
Resistance 1000Ω to 40MΩ 0.025
Capacitance 4nF to 40mF 0.8
Frequency Counter 40Hz to 4MHz 0.002
Duty Cycle 20% to 80% 0.1
Temperature -200℃ to 1200℃
Diode Test Open Circuit Voltage:±3V

TRMS AC Multimeter MTX 203

Salient Features:
  • 750V ACV & 1000V DCV
  • TRMS AC or AC + DC Current and Voltage
  • 6000 count large scale digital display
  • Autoranging and manual selection
  • Backlit screen and built-in torch
  • Min, Max, ΔREL, Hold and NCV functions
  • Beep Guard
  • Shock proof from 4 feet drops
  • Comfortable holster with probe holder and tilt stand
  • Safety standard CAT III 600V

 

 

Parameter Range Accuracy %
Display Backlit LCD
AC Voltage 0.6 V to 750V 0.5
DC Voltage 0.6 V to 1000V 0.2
AC/DC Current 10 μA to 10 A 0.5
Resistance 1 Ω to 60 MΩ 0.5
Capacitance 1 nF to 100 mF 2
Temperature with
K- thermocouple
-55 to +1 200 °C 2
Weight 170 x 80 x 50 mm / 320 g

TRMS AC, DC, AC+DC Multimeter Clamps C.A 5273, C.A 5275, C.A 5277

Salient Features:
  • 1000V ACV/DCV
  • TRMS measurement
  • Double 6000-count backlit display with dual-mode
  • VLowZ low-impedance Voltage measurement
  • Resolution from 10 μV and 1 μA
  • Quick response and high crest factor
  • Min / Max / Peak functions and relative or differential measurements
  • Safety standard CAT IV 600V
Parameter Range
Models C.A 5273 C.A 5275 C.A 5277
DC Voltage 1000V
DCV accuracy 0.2% 0.09%
AC Voltage  1000V
AC Current 6 A / 10 A 6000 µA to 10 A
DC Current 6 A / 10 A 6000 µA to 10 A
Resistance 600 Ω to 60 MΩ
Frequency 600 Hz to 50 kHz
Capacitance 6 nF to 60 mF
Temperature -59.6to 1200 °C NA -59.6 to 1200 °C

ASYC IV Range Digital Meter Clamps MTX 3290, MTX 3291, MTX 3292, MTX 3293

Salient Features:
  • Current 10 A autoranging
  • Min/Max , Avg & RTD for Voltage and Current Peaks
  • Software for RT processing of the data on a PC (MTX 3291)
  • Trace, cursors and zoom on recordings
  • Recording of 10 sequences
  • Record upto 1000 (MTX 3292), 6500(MTX 3293) measurements.
  • IP67 protection against water and dust, ideal for outdoor Conditions
  • communication mode based on the SCPI standard, via USB or Bluetooth
Parameter Range
Model MTX 3290 MTX 3291 MTX 3292 MTX 3293
DC,AC & AC+DC Voltage 60 mV to 600 V 60 mV to 1000 V 100 mV to 1000 V
DC accuracy 0.3 % 0.05 % 0.03 % 0.02 %
AC & AC+DC Bandwidth 20 kHz 100 kHz 100 kHz 200 kHz
DC,AC & AC+DC Current 600 µA to 10 A /20 A (30 s max) 1000 µA to 10 A /20 A (30 s max)
DC accuracy 0.08 % 0.01 %
Resistance 600 Ω to 60 MΩ 100 Ω to 100 MΩ
Capacitance 6 nF to 60 mF 1 nF to 10 mF
Temperature PT100/1000 ,-200 °C to 800 °C,
PWM filter 4th-order 300 Hz low-pass filter for measuring on variable speed drives of asynchronous motors
V-output clamp function
for direct reading
Integration of the ratio: 1/1 ,1/10,1/100,1/1000 mV/A Parameterizable Ax ratio

LCR Meter

Handheld Digital LCR Meter ATEST LCR 900

Salient Features:
  • Measurement Parameters: L,C,R,D,Q,θ
  • Parallel/Serial test mode
  • 2000/20,000 count digital display
  • Sorting mode for QC
  • 46 Analog Bar Graph Segments
  • Auto Backlit, Dual display
  • Self Calibration
  • External USB power operation
  • Zeroing Mode
  • USB Interface
  • 2 Wires Easy Testing
  • 4 Wires Accuracy Testing
Parameter Range Accuracy %
Inductance 20μH~20KH 0.2
Capacitance 20pF~20mF 0.2
Resistance 20Ω~200MΩ 0.2
DC Resistance 200Ω~200MΩ 0.2
Q 0.000~2000
D 0.000~2000
θ ±90°

Tweezer LCR Meter ATEST LT 902

Salient Features:
  • Auto Selection of LCR Testing
  • Measurement Parameters: L,C,R,D,Q,θ, DCR
  • Testing Frequency: 100Hz/120Hz/1KHz/10KHz selectable
  • Self Calibration
  • 20,000 count Digital Display
  • External DC power operation
  • Parallel/Serial test mode
  • Sorting mode for QC
  • Zeroing Mode
  • Optical USB Interface
  • Tweezers Easy Testing
Parameter Range Accuracy %
Inductance 0.001μH~2000mH 0.2
Capacitance 0.01pF~200μF 0.2
Resistance 0.001Ω~200MΩ 0.2
DC Resistance 0.01Ω~200MΩ 0.2
Q 0.000~1999
D 0.000~1999
θ ±90°

Tweezer LCR Meter ATEST LT 904

Salient Features:
  • Auto Selection of LCR Testing
  • 0.2% basic accuracy Capacitance and Inductance
  • Measurement Parameters: L,C,R,D,Q,θ, DCR
  • Testing Frequency: 100Hz/120Hz/1KHz/10KHz/100KHz selectable
  • 20,000 count digital display
  • Self Calibration
  • External DC power operation
  • Parallel/Serial test mode
  • Sorting mode for QC
  • Data Hold
  • Zeroing Mode
  • Optical USB Interface
  • Tweezers Easy Testing
Parameter Range Accuracy %
Inductance 0.001μH~2000mH 0.2
Capacitance 0.01pF~200μF 0.2
Resistance 0.001Ω~200MΩ 0.2
DC Resistance 0.01Ω~200MΩ 0.2
Q 0.000~1999
D 0.000~1999
θ ±90°

Laboratory Equipment

HandHeld Oscilloscope with Isolated Channels

Salient Features:
  • Two isolated Channels
  • TRMS measurement
  • 20 or 40 MHz oscilloscope
  • Double 8000-count TRMS Multimeter
  • Power analyser, harmonic analyser
  • Built-in 31storder harmonic analyser
  • To store graphic recordings of 2700 measurements
  • Display curves on a PC in real time
  • Safety standard CAT III 600 V
Parameter Range
Models OX 5022 OX 5042
Bandwidth 20 MHz 40 MHz
Bandwidth Limiter 1.5MHz, 5kHz
Sampling rate Automatic, Triggered, one shot
Memory Depth 2500 points
AC,DC&AC+DC Voltage 600 mV to 600 VRMS
Resistance 80 Ω to 32 MΩ
Capacitance 5 nF to 5 mF
Harmonic analysis 31st orders, freq from 40 to 450Hz
Weight 214x110x57mm / 1.2 kg

Portable Oscilloscopes with Isolated Channels: OX 9062, OX 9102, OX 9104, OX 9304

Salient Features:
  • – (Model dependent)
  • 7’’ WVGA wide colour TFT touch screen
  • Touch screen – andROID-type icons and graphical commands – customizable channel colours
  • Automatic measurements
  • The MATH functions
  • The real-time Fast Fourier Transform (FFT) for frequency decomposition of your signals on 4 channels
  • Wired ETHERNET LAN network with integrated DHCP server for easy connection to your network, with the possibility of activating the WiFi radio link to communicate with a PC, tablet or smartphone using the dedicated interfaces.
  • USB for interfacing with a PC: record, recall or load configurations.
  • µSD > 8 GB, default storage, given priority over the 1 GB internal memory
Parameter OX 9062 OX 9102 OX 9104 OX 9304
Models
Number of Channels 2 isolated channels 4 isolated channels
Bandwidth 60 MHz 100 MHz 100 MHz 300 MHz
Input impedance 1 MΩ ± 0.5% , approx. 12 pF
Maximum sampling rate 2.5 GS/s in one-shot mode on each channel
Memory depth 100 kpts per channel and file viewer in the manager
AC, DC& AC + DC Voltage 600 mV to 600 VRMS, 800 mV to 800 VDC – VDC accuracy +/- (0.5 % + 25 D) – 200 kHz bandwidth
Harmonic analysis 2 or 4 (depending on model), 63rd orders, fundamental frequency 40 to 450 Hz in auto or manual mode
Resistance/Capacitance 80 Ω to 32 MΩ / 5nF to 5mF
Frequency 200 kHz
Single and three-phase power Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements
Logger Duration: 20,000 s – Interval: 0.2 s – Files: 1,00,000 measurements
PC communication –
software link
Ethernet (100 baseT), WiFi-USB (device, 12 Mbs) – “ScopeNet” application software for PC

Insulation and Continuity Tester

Insulation Tester ATEST S 1100

Salient Features:
  • TRMS Auto AC/DC Voltage Detection
  • Innovative Insulation Resistance Tester
  • 4000 count extra large digital display
  • Insulation test range: 0.01M Ω to 20G Ω
  • Automatic calculation of (PI) and (DAR)
  • Convenient compare (Pass/Fail) function
  • Ergonomically designed Remote probe for repetitive testing
  • Measurement of TRMS AC Voltages up to 600V DC
  • Compact, robust and shockproof housing, with protective holster
  • Memory: 5 x 100 memories available
  • Supplied with active test probe
Parameter Range Accuracy %
DC Voltage 600V 1
AC Voltage 600V 1.5
Earth Bond
Resistance
40Ω ~ 40kΩ 1.5
Test Voltage 50V, 100V, 250V, 500V, 1000V
Insulation Resistance 0.001M Ω ~ 20.0GΩ 1.5
Continuity under 200mA

Insulation and Continuity Tester C.A 6522, C.A 6524, C.A 6526, C.A 6532, C.A 6534, C.A 6536

Salient Features:
  • Test Voltage from 10 V to 1000 V / 200 GΩ
  • Manual, Lock, Timer and PI / DAR Ratios
  • Visual Pass / Fail: Red / Green
  • 200 mA / 20 mA continuity with active protection without fuses
  • Measurement of V (TRMS & DC), F, Ω, kΩ, C and cable length
  • ΔRel mode & configurable alarms
  • Storage of measurements in memory
  • Activation of remote tests
  • Real-time display
  • DAR and PI references
  • Graphical plot of the tests
  • Generation of measurement reports
Parameter Range
Models C.A 6522 C.A 6524 C.A 6526 C.A 6532 C.A 6534 C.A 6536
Voltage / Accuracy 0.3 V – 700 V / 3%
Frequency 15.3 Hz – 800 Hz
Insulation Test Voltage 250-500 -1000 V 50 – 100 – 250 – 500 – 1000 V 50 – 100 V 10- 25 – 100 – 250 – 500 V 10 V to 100 V in 1 V steps
Range at maximum test Voltage 40 GΩ 200 GΩ 20 GΩ 50 GΩ 20 GΩ
Display of test Current 0.01 µA – 39.99 µA / 10 nA; 40.0 -399.9 µA / 100 nA; 0.400 -2.000 mA/ 1 µA
Accuracy of test Current ± (10 % + 3 cts)
PI/DAR ratios NA 10 min / 1 min – 1 min / 30 s NA NA
Continuity 0.00 Ω-10.00 Ω (200 mA) 0.00 Ω-10.00 Ω (200 mA); 0.0 -100.0 Ω (20 mA)
measurement Current 200 mA range: 200 mA (-0 mA +20 mA); 20 mA range: 20 mA ± 5 mA
Resistance range /
Resolution / Accuracy
NA 0 -3999 Ω / 1 Ω; 4.00 kΩ – 39.99 kΩ / 10 Ω / ± (3 % + 2 cts)
40.0 kΩ – 399.9 kΩ / 100 Ω; 400 kΩ-1000 kΩ / 1 kΩ / ± (3 % + 2 cts)
Capacitance range /
Resolution
NA NA 0.1 nF -399.9 nF / 0.1 nF 400 nF -3999 nF / 1 nF 4.00 µF -10.0 µF / 10 nF NA NA
Storage NA 300 measuremen 1300 measurements NA
Communication NA NA Bluetooth® Class II NA

Thermal

Infrared Thermometer(Pocket size) ATEST TI 304

Salient Features:
  • Large Scale LCD display InfraRed Thermometer
  • Distance to Spot Ratio 8:1
  • Single point laser sighting
  • Holds temperature reading for 10 seconds
  • Easy °C/ °F unit switching
  • Best accuracy in its class ±1°C of reading
  • Integrated Non-Contact AC Voltage detection with LCD indication
  • Ultra bright white LED torch
  • Single AAA size battery operation
  • Pocket Clip designed for easy carrying
Parameter Range Accuracy %
Temperature°C -30°C ~ 500°C 1
Temperature°F -22°F ~ 932°F 1.5
Response Time 0.5 sec
Distance to Spot 8:1
Spectral Response 6.5um ~ 18um
Emissivity 0.95
Non-Contact
Voltage Detection
60VAC ~ 600VAC

Infrared Thermometer (8:1) ATEST TI 300

Salient Features:
  • Simple One-handed operation
  • Laser Targeting
  • LCD with Back Light
  • °C/ °F Select Switch
  • Laser ON/OFF Switch
  • Automatic Power off
  • Display Hold function
Parameter Range Accuracy %
Temperature°C -20~500°C 2
Temperature°F – 4~932°F 2
Response Time 500m Sec
Distance to Spot 8:1
Emissivity Pre-Set at 0.98

Infrared Thermometer (12:1) ATEST TI 302

Salient Features:
  • Simple One-handed operation
  • Laser Targeting
  • LCD with Back Light
  • °C/ °F Select Switch
  • Laser ON/OFF Switch
  • Automatic Power off
  • Display Hold function
Parameter Range Accuracy %
Temperature°C -20~500°C 2
Temperature°F – 4~932°F 2
Response Time 500m Sec
Distance to Spot 12 : 1
Emissivity Pre-Set at 0.98

Infrared Thermometer (10:1) C.A 1860

Salient Features:
  • Distance/spot ratio 10:1
  • Single laser
  • Configurable high and low alarms
  • Instantaneous mode, Max/ Min/ Avg
  • Differential (DIF), continuous measurement by locking the measurement trigger, alarms
Parameter Range Accuracy %
Temperature°C -35 °C to + 450 °C 2
Temperature°F -31°F to + 842°F 2
Response Time 250 ms
Distance to Spot 10 : 1
Emissivity 0.95

Infrared Thermometer (12:1) C.A 1862

Salient Features:
  • Distance/spot ratio 12 : 1
  • Dual laser
  • Configurable high and low alarms
  • Instantaneous mode, Max/ Min/ Avg
  • Differential (DIF), continuous measurement by locking the measurement trigger, alarms
Parameter Range Accuracy %
Temperature°C – 35 °C to + 650 °C 2
Temperature°F -31 °F to + 1202°F 2
Response Time 250 ms
Distance to Spot 12 : 1
Emissivity adjustable from 0.1 to 1.0

Thermal Imager TCA 1950 & TCA 1954

Salient Features:
  • Simple to use
  • Just 3 seconds to start
  • -20°C to + 250°C
  • 80 x 80 Sensor (TCA 1950)
  • 160 × 120 Sensor (TCA 1954)
  • Voice messages can be stored with images
  • Rugged – 2m fall resistance
  • Light weight – just 700g
  • IFOV (spatial resolution) 4.4 mrad
  • CAmReport Software for PC download & analysis
  • Display mode: thermal image, real image with automatic parallax compensation
  • Connectivity: Bluetooth, USB
  • 2 GB (approx. 4000 images) on micro SD card, up to 32 GB with removable card
Parameter Range
Models TCA 1950 TCA 1954
Detector 80 × 80 160 × 120
Frequency 9 Hz
Temperature -20°C to +250°C
Thermal Image performance
Field of View 20° x 20° 38° x 28°
IFOV 4.4 mrad 4.1 mrad
Min Focal Distance 40cm 30cm
functions for Analysis
Vocal comments Yes via Bluetooth (earphones provided)
Display Image Thermal Image / Real Image
Image format .bmp .png
Battery NiMH recharegeable Batteries

RayCAm Software

The RayCAm Report standard software is equipped with a very simple user interface allowing:

Analysis of the thermograms with the following tools:

  • Cursors (automatic display of the temperature at the point chosen)
  • Thermal profile (automatic display of the Min/Max/Avg temperatures on the line)
  • A square or circle for zone analysis
  • Result tables quickly and automatically show all the information/thermogram analysis tools
  • Polygons and polylines for analysing certain areas of the thermogram in greater detail

RayCAm Report standard allows you to define the emissivity of each point in the thermogram, an essential feature when the thermogram contains different materials.

Electrical Safety

Multifunction Insulation Tester C.A 6133 & C.A 6131

Salient Features:
  • Earth measurement by stake and loop methods
  • Continuity measurement at 0.2A
  • Insulation testing
  • RCD testing: Current and trip time
  • Automatic test sequences
  • Storage of test results
  • Android application for report generation
  • Phase rotation: 45 to 550V; 45 to 65 Hz
  • Power supply by mains-rechargeable batteries, USB socket or vehicle cigarette lighter
  • Safety standard CAT III 600V
Parameter Range
Models C.A 6131 C.A 6133
Continuity  0.00 to 9.99 Ω
Resistance 1 to 9999 Ω
Insulation 250 V / 500 V 250 V/500 V/ 1000 V
Earth res- 3P NA 0.50 to 2000 Ω
Frequency NA 30.0 to 999.9 Hz
Current Via clamp with
Voltage output
Via MN73A clamp
Voltage 0 – 800V
RCD test (V) 90 to 450 V
Trip time 0.5 x I ΔN ; 1 x I ΔN ; 5 x I ΔN / 5.0 to 300 ms

Insulation Tester(Megohmmeter) C.A 6541 & C.A 6543

Salient Features:
  • Insulation: up to 4 TΩ (5 ranges) at 50/100/250/500 and 1000 V DC
  • Automatic calculation of insulation quality ratios: DAR and PI
  • Programmable test duration and plotting of the R(t) curve (automatic storage of 20 samples) (C.A 6541)
  • Storage of measurements (128 kB)(C.A 6543)
  • Microprocessor-controlled
  • Insulation test Voltages can be locked
  • Programmable alarms. Remote control probe available as an option
  • Safety standard CAT III 600V
Parameter Range
Models C.A 6541 C.A 6543
Voltage 1 to 1000 VAC/DC
Insulation 50 / 100 / 250 / 500 / 1000 VDC
Range 2 kΩ to 4 TΩ
Continuity 0.01 to 40 Ω
Resistance 0.01 to 400 kΩ
Capacitance  0.005 to 4.999 μF
Storage NA 128 kB
PC software NA Dataview® (option)

Insulation Tester(Megohmmeter) C.A 6505, C.A 6545, C.A 6547 & C.A 6549

Salient Features:
  • 4 fixed test Voltages: 500 / 1000 / 2500 and 5000 V
  • Adjustable test Voltage position: 40 to 5100 V in 10 V or 100 V increments
  • Large backlit LCD screen with digital display and bargraph
  • Large number of functions: programmable test duration, test Voltage locking, smooth function, programmable alarms, etc.
  • Storage of several thousand measurements
  • RS 232 connector for connection to PC (Megohmeter data processing software) or very compact serial printer
  • Safety standard CAT III 1000V
Parameter Range
Models C.A 6505 C.A 6545 C.A 6547 C.A 6549
Voltage 1 to 5100 V AC/DC
Insulation 500/1000/ 2500 / 5000 VDC + variable from
50 V to 5100 VDC (10 or 100 V increments)
Range 10 kΩ to 10 TΩ
Capacitance 0.001 to 49.99 μF
Current 0.001 nA to 3000 μA
Voltage ramp NA 5 steps
Quality ratios DAR / PI DAR / PI / DD
Storage 4 kB 128 kB
PC software NA Dataview® (option)

`Electrical Safety

Digital Insulation Tester C.A 6550, C.A 6555

  • Wide measurement range from 10 kΩ to 25 TΩ
  • Fixed or programmable test Voltage from 40V to 15 kV (C.A 6555) &40v to 10kv(C.A 6550)
  • Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
  • Multiple test modes: Voltage ramp and step with “burning”, “early break” and “Ilimit” modes
  • 80,000-measurement storage capacity and real-time clock
  • Optically-isolated USB communication for transfer onto PC and report generation with DataView® software.
  • Safety standard CAT IV 1000V
Parameter Range
Models C.A 6550 C.A 6555
Test Voltages 10kV 10kV
Ranges 10,000 V10 kΩ to 25 TΩ 10kV
Variable Test Voltages 40 V – 10,000 V 10kV
Ramp mode start Voltage/ endVoltage/duration
Step mode Up to 10 steps
Capacitance 0.001-9.999 µF / 10.00-49.99 µF
Leakage Current 0 – 8 mA
Weight 340 x 300 x 200 mm, 6.2 kg

Earth and Resistivity Tester C.A 6460 & C.A 6462

Salient Features:
  • Measurement range: 0.01 to 2000 Ω (3 automatic ranges)
  • Change from 4-wire method to 3-wire method
  • Measurement frequency: 128Hz
  • Easy connection of stakes by means of colour-coded terminals
  • Large backlit digital display with 2,000 counts
  • 4500 measurements of 15s each (C.A 6460)
  • 1180 measurements of 15s each (C.A 6462)
  • IP53 leakproof case with folding cover and carrying handle
  • Safety standard CAT III 50 V
Parameter Range
Models C.A 6460 C.A 6462
3PMethod Range 0.01 to 2000Ω
Frequency 128Hz
4PMethod Range 0.01 to 2000Ω
Resolution 3P/4P 10 mΩ/ 100mΩ/1Ω
Resistivity 0.01 to 99.9kΩ
Measurement 4500 measurement of 15 s 4500 measurement of 15 s

4500 measurement of 15 s 1180 measurement of 15 s Earth and Resistivity Tester C.A 6470N & C.A 6471

Salient Features:
  • 3-pole and 4-pole measurements
  • Selective 4-pole measurements
  • Earth Loop measurement with 2 Clamps (C.A 6471)
  • Resistivity (Wenner + Schlumberger methods)
  • Earth coupling
  • Continuity & resistance
  • Excellent accuracy and resolution
  • Standard software for data recovery and processing of the results
  • Safety standard CAT IV 50 V
Parameter Range
Models C.A 6470N C.A 6471
3PMethod 0.01 Ω to 99.9 kΩ
4PMethod 0.001 to 99.99 kΩ
Earth measurement with 2 clamps NA 0.01 to 500 Ω
Resistivity  0.01 to 99.9 kΩ
DC resistance 0.12 Ω to 99.9 kΩ 0.001 Ω to 99.9 kΩ

Earth and Resistivity Tester with Adapter for Pylon Earth Measurements C.A 6472, C.A 6474

Salient Features:
  • 3P Measurement up to 10 kΩ and stray Voltages up to 60 V RMS
  • 4P and selective 4P measurement
  • Earth loop measurement with 2 clamps from 0.01 Ω to 500 Ω
  • Earth coupling measurement
  • Soil resistivity measurement: simply program the distances used for the measurement and the tester then calculates r using the Wenner oe Schlumberger methods
  • Ground potential measurement
  • Storage of 512 test results
  • Continuity and resistance measurement
  • Pylon earth measurement with the C.A 6474
  • Safety standrad CAT IV 50V
Parameter Range
Specifications C.A 6472 & C.A 6474
measurements Earth,Selective earth, Resistivity, Coupling, Continuity, Pylon earth (with C.A 6474)
Type 3P/4P/4P with clamp/ 2 calmps
Meas range 0.001 to 100KΩ ( automatic ranging)
No load Voltage 16V or 32 V ( as required)
Frequency 41 Hz to 5078 Hz
Rod Resistance 0.12 Ω to 99.9 kΩ
U disturbance 0.12 Ω to 99.9 kΩ
Noise Rejection 0.12 Ω to 99.9 kΩ
Weight 272x250x128 mm 3.2 kg / C.A 6474: 2.3 kg

Micro-Ohmmeter C.A 6240, C.A 6255, C.A 6292

Salient Features:
  • 4-wire measurement method
  • 4-wire measurement method (7 ranges, 3 with a 10 A Current)(C.A 6255)
  • Test Current up to 10 A
  • Max resolution 1 µΩ
  • Automatic Power off
  • Power supply: NiMH rechargeable battery
  • Storage: 100 measurements
  • C.A 6292 record upto 8000 measurement.
  • Communication via USB optical link
  • Data export software
  • IP53 protection
  • Safety standrad CAT III 50V
Parameter Range
Models C.A 6240/ C.A 6255 C.A 6292
Resistance 0.1 μΩ to 1μΩ 0.1μΩ to 1Ω
Resolution 3P/4P/4P with clamp/ 2 calmps 0.1μΩ to 10μΩ
Accuracy 0.25% ± 1%
Measurement
Current
1mA to 10A Clamp
BSG NA Yes
Output Voltage NA 110 Vac: 4.2 V
220 Vac: 8.6 V
Weight 270x250x180mm/4.5Kg

Ratiometer DTR 8510

Salient Features:
  • Transformation ratio: from 0.8000:1 to 8000:1 (power and Voltage ransformers) and from 0.8000 to 1000 (Current transformers) – Autorange function
  • Testing by excitation of the primary and reading of the secondary, in order to guarantee user safety
  • Digital display – display of the ratios, winding directions – % deviation in relation to the rated values and excitation Current
  • Storage up to 10,000 measurement
  • USB connection and DataView PC software
  • IP53 Protection
  • Safety standard CAT IV 50V
Parameter Range Accuracy %
Ratio Range (VT/PT) Auto ranging- 0.8000 to 8000 :1 ±0.1
Ratio Range (CT) Auto ranging- 0.8000 to 1000.0 ±0.5
Excitation
Frequency
70 Hz
Excitation Current 0 to 1000 mA ±2
Excitation Signal VT/PT Mode: 32Vrms max CT Mode: Auto Level 0 to 1 A, 0.1 to 4.5V
Measurement
Method
In accordance with IEEE Std C57.12.90™- 2006

Physical and Environmental

Humidity and Temperature Meter ATEST EH 500

Salient Features:
  • LCD with Back Light
  • Battery Status Display
  • Memory Status Display
  • Shipped with wall hanging tag
  • 32000 Records Datalogger per channel
  • PC Interface
  • Windows Software
  • ATEST 600C Communication Base
Parameter Range Accuracy %
Temperature °C  -30~70°C 0.7
Temperature °F -22~158 °F 0.7
Humidity 5%~98%RH 3

Humidity and Temperature Meter ATEST EH 502

Salient Features:
  • Dew Point and Wet Bulb Temperature measurement
  • Fast Response Time
  • Data Hold
  • Auto Shut Off For Battery Saving
  • Min/Max function
  • Dual Displays: Primary Display For Humidity
  • Secondary Displays For Temperature
Parameter Range Accuracy %
Temperature °C -20~60°C 0.8
Temperature °F -4~140 °F 1.6
Humidity 0~99%RH 3

Humidity and Temperature Meter ATEST EH 504

Salient Features:
  • Dew Point and Wet Bulb Temperature measurement
  • Fast Response
  • Auto Shut Off For Battery Saving
  • Min/Max function
  • Data Hold
  • Dual Displays: Primary Display For Humidity
  • Secondary Displays For Temperature
  • LED Back Light
Parameter Range Accuracy %
Temperature °C -20~60°C 0.8
Temperature °F -4~140 °F 1.6
Humidity 0~99%RH 2.5

Thermo Hygrometer C.A 1246

Salient Features:
  • Dew Point measurement
  • Min/Max/ Hold functions
  • Alarms, °C or °F, backlighting
  • Recording up to 1 million points
  • USB or Bluetooth interfaces
  • IP54 casing
  • Shockproof protective sheath available as an accessory
Parameter Range Accuracy %
Temperature °C – 10.0 to + 60.0°C 0.5
Temperature °F 14.0 to + 140.0°F 1.6
Humidity 3.0 to 98.0 %RH 2
Dew Point °C – 20.0 to + 60.0°Ctd
Dew Point °F -4.0 to + 140.0 °Ftd

Physical and Environmental

Four Channel Data Logger Thermometer ATEST T4 340D

Salient Features:
  • Measures K, J, E, T Type Thermocouples
  • Temperature Alarm function
  • Fast Response with High Accuracy
  • Min/Max/Avg Recording of all channels
  • USB Interface, PC software included
  • Datalogging Up to 16,000 Points Each Channel
  • T1-T2 function(Subtraction).
  • Recall function to Instantly Read-out Up to 100 Sets manually Saved Data
Parameter Range Accuracy %
Temperature°C -200~1370°C 0.1
Temperature °F -328~2498°F 0.1

Logger Contact Thermometer C.A 1821, C.A 1822, C.A 1823

  • J, K, T, N, E, R and S thermocouples (C.A 1821 & C.A 1822)
  • Pt100 and Pt1000 resistance probes (C.A 1823)
  • Min/Max
  • Compact and magnetized for fixed or portable use
  • Recording of up to 1 million points
  • Recording can be Triggered on Alarm Thresholds
  • Battery life of up to 3 years
Parameter Range
Models C.A 1821 C.A 1822 C.A 1823
Channel°F 1 channel
J,K,T,N,E,R,S
2 channels
J,K,T,N,E,R,S
1 channel
Pt100, Pt1000
Range /
Resolution
– 210°C to +1,200°C
-346°F to + 3,212°F
-100 to +400° C
-148 to +752 °F
Resolution 1°C/1°F 0.1°C/0.1°F

Precision RTD Thermometer ATEST TR 320

Salient Features:
  • Precision Platinum Temperature Sensor
  • High Accuracy with 0.01°C resolution
  • Automatic Locked Push-pull Connector For Easy Connection
  • Large Back Light LCD
  • Dual Display
  • Min/Max , Hold function
  • °C/°F Scale Selectable
  • DataRelative function
  • 100 manual Recording Data Memory Include On Meter Readout function
Parameter Range Accuracy %
Temperature°C -100~400°C 0.1
Temperature°F -148~752°F  0.1
Sampling Rate 2 time/sec.
Sensor Type Platinum temperature -measurement resistor (Pt100/4 line type)

RTD Thermometer (Water Proof) ATEST TR1 322

Salient Features:
  • IP67 Water Proof housing to work for almost all kinds Of Environments
  • PT Temperature Sensor For Less environmental dependent reading
  • Adapt For PT100, PT 500 and PT1000 sensors with a Value Of 3850
  • Min/Max/Avg function
  • LCD Back Light
  • °C/°F Scale Selectable and 0.1°C, 0.1°F resolution
Parameter Range Accuracy %
Temperature°C -100~300°C 0.1
Temperature°F -148~572°F  0.1
Sampling Rate 2 time/sec.
Sensor Type Platinum temperature-measurement resistor (Pt100/4 line type
Water Resistance IP67

Thermocouple probe

K Type General Purpose Bead probe

Measurement Range: -50°C to 200°C-58°F to 392°F
tolerances : ±2.2°C (±3.9°F)

K Type Immersion probe

Measurement Range: -50°C to 700°C-58°F to 1292°F
tolerances : ±2.2°C (±3.9°F)

K Type flat surface probe

Measurement Range: -50°C to 400°C-58°F to 752°F
tolerances : ±2.2°C (±3.9°F)

K Type Piercing probe

Measurement Range: -50°C to 600°C-58°F to 1122°F
tolerances : ±2.2°C (±3.9°F)

K Type flat surface probe

Measurement Range: -50°C to 400°C -58°F to 752°F
tolerances : ±2.2°C (±3.9°F)

K Type air probe

Measurement Range: -50°C to 800°C -58°F to 1472°F
tolerances : ±2.2°C (±3.9°F)

Platinum resistance thermometer sensor Pt 100(4wires)

Measurement Range: -100°C to 400°C ; -148°F to 752°F
Accuracy: Class A, ±0.15°C ±0.002t
Temperature sensor Dimension Approx 0.125” Temperature sensor Length: Approx 4.72”

Platinum resistance thermometer sensor Pt 100(4wires)

Measurement Range: -100°C to 400°C ; -148°F to 752°F
Accuracy: Class A
Temperature sensor Dimension Approx 0.2” Temperature sensor Length: Approx 9.05”

Physical and Environmental

Hygro Thermometer ATEST EH 520

Salient Features:
  • Large, Easy-to-read Dual LCD Displays Humidity and Temperature
  • 3%RH Humidity accuracy
  • Calibration available on site
  • Desk Or wall Mount
  • Min/Max Value Monitor
  • Audible and Visual Alarms, with Adjustable Set Points, Warns If Limits Are Exceeded
Parameter Range Accuracy %
Temperature°C -20~60°C 0.8
Temperature°F -4~140°F 1.5
Dew Point °C -20°C~60°C 0.8
Dew Point °F -4~140°F 1.5
Humidity 0~100%RH 3

Data Logger Hygro Thermometer ATEST EH 540D

Salient Features:
  • Interchangeable Digital probes
  • Thermistor Sensor For Temperature measurement, Fast Response Time
  • Dual Display
  • Dew Point measurement
  • Response Time (@t90): Humidity: 60 sec Temperature: 10 sec
  • PC Interface & Extending Cable Available
  • 16,000 Records Data Logger
  • Auto Shut Off For Battery Saving
  • Sensor: Electronic capacitance polymer film sensor/NTC
Parameter Range Accuracy %
Temperature°C -20~60°C 0.8
Temperature°F -4~140°F 1.5
Humidity 0~100%RH 2

Hot Wire Anemometer ATEST EA 920

Salient Features:
  • Air velocity measurement: m/s, km/hr, ft/min, MPH,
  • Knots & build in temperature°C / °F, humidity %RH
  • Air velocity compensation in atmospheric pressure
  • Air flow measure: CMM, CFM
  • Telescoping hot wire probe
  • Fast response
  • Min/Max/Avg & 2/3Vmax function with USB interface supply power
  • Data Hold function
Parameter Range Accuracy %
Air Velocity 0~25 m/s 3
Air flow 0~999900 m3/min
Temperature°C -20°C~60°C 0.8
Temperature°F -4°F~140°F 1.5
Humidity 0~100%RH 3.5
Sampling Rate 2 time/sec

Logger Thermo- Anemometer C.A 1227

Salient Features:
  • Air speed units: m/s, km/h, fpm, mph
  • Flow rate units: m3/s, m3/h, l/s, cfm
  • Min/ Max/ Average/ MAP and Hold functions / Backlighting
  • Type of sensor : Vane / optical detection
  • Recording up to 1 million points
  • USB or Bluetooth interfaces
  • Vane diameter: Ø8 mm
Parameter Range Accuracy %
Air Velocity 0.50 m/s to 27.0 m/s 3
Air flow 0.00 to 2999 m³/h 8
Temperature°C -20.0 °C to +50.0 °C 0.8
Temperature°F -4 °F to +122 °F 1.6

Light Meter ATEST EL 720

Salient Features:
  • Fc / lx function Selectable
  • Auto Ranging
  • Automatic Power off
  • Hold function
  • Range Display
  • Automatic Zero when Power On
Parameter Range Accuracy %
Light Range (lx) 0.00~40,000 lx 3
Light Range (fc) 0.000~4000 fc 3
Sample Rate 2 times/sec

Light Meter ATEST EL 722 & ATEST EL 724

Salient Features:
  • Fc / lx function Selectable
  • User Adjustable Parameter For Special Light Source ( EL 724)
  • Data Hold function
  • Range Display
  • Big LCD Display
  • Automatic Zero When Power on
  • Detachable & Rotatable Light Sensor
Parameter Range Accuracy %
Light Range (lx) 0.0~199900 lx 3
Light Range (fc) 0.0~19990 fc 3
Sample Rate 2 times/sec
ATEST EL 724
Light Range (lx) 0.0 to 99.9/1999/
19990/199900 lx
3
Response Time 0.5 sec

Light Meter C.A 1110

Salient Features:
  • ± 3% of the reading on incandescent sources (default)
  • ± 6% of the reading on LEDs (3,000 K to 6000 K)
  • ± 9% of the reading on fluorescent sources
  • Min/ Max/ Average/ MAP and Hold functions, lx or fc / Backlighting
  • Recording up to 1 million points
  • USB or Bluetooth interfaces
  • IP50 casing
Parameter Range Accuracy %
Light Range (lx) 0.1 lx to 2,00,000 lx 3
Light Range (fc) 0.01 fc to 18,580 fc 4
Response Time 0.5 sec

Tachometer C.A 1725, C.A 1727

Salient Features:
  • Measurements up to 1,00,000 rpm
  • Large number of functions, Memories and automatic routines for data acquisition
  • Measurement of rotation speed, linear speed, count, frequency and period
  • Extensive programming possibilities
  • USB link for processing the results on a PC (C.A 1727)
Parameter Range
RPM functions 60 to 1,00,000 RPM
m/min function 60 to 10,000 m/min
Hz function 1 to 10,000Hz
ms function 0.1 to 1000ms
Repot function 0.1 to 10%
Counting function 0 to 1,00,000events

Sound Level Meter ATEST ES 700

Salient Features:
  • 60dB Dynamic space in each range
  • Time weighting Fast/Slow
  • Frequency weighting A/C
  • Min/Max function
  • Microphone: ½ inch Electret condenser microphone
  • Auxiliary Outputs: AC/DC Output
Parameter Range Accuracy %
Sound level 30~130dB 1.4
Frequency 20Hz to 8KHz

Indoor Air Quality (CO2 Meter) C.A 1510

Salient Features:
  • Recording: 1 million values stored on the product in the form of several measurement campaigns.
  • USB interface (product recognized as a USB key) or Bluetooth for wireless use
  • Recording interval : Customizable from 1 minute to 2 hours
  • Graphic representation or as table of values – Data export – Real-time mode ,Report generation
  • On-site calibration module with adapter, tube and software for adjusting the zero and the 1700 ppm threshold
Parameter Range Accuracy %
CO2 Measurement 30~0 to 5000 ppm 3
Temperature -10 °C to +60 °C 0.5
Humidity 5 to 95 % RH 2

Carbon Monoxide Meter (CO) ATEST EG 800

Salient Features:
  • Large LCD dual displays for CO and TEMP measurement
  • Backlight for easy screen viewing under dim lighting conditions
  • Adjustable alarm limits
  • CO level beeper can be silenced if desired
  • Automatic Zero point adjustment
  • Max / Data Hold / Auto Power off
  • Easy to replace battery
  • Replaceable CO sensor extends tool life
Parameter Range Accuracy %
CO 0 to 1000 ppm 5
Temperature °C -20 to 70°C 0.8
Temperature °F -4 to 158°F 1.5
Sensor Stabilized electrochemical CO
specific sensor

H2 Gas Leak Detector ATEST EG 820

Salient Features:
  • Mixture 5% Hydrogen (H2) + 95% Nitrogen(N)
  • Sensitivity: Less than 5 ppm ; 2g/year
  • Sensor life: approx. 1 year
  • Warm up time: 45 seconds
  • DC brushless fan
  • High-median-Low leak sensitivity selector
  • 15.5 (40 CM) flexible stainless probe
  • Ambient concentration reset
  • Automatic zero and background compensation

Power Quality Analyser KRYKARD ALMxx

KRYKARD ALM 36

Salient Features
  • 4 Voltage & 4 Current channels
  • Alarms – Capture up to 16,362 alarms
  • Inrush – (capture I & V waveforms)
  • Transients – Capture up to 210 transients
  • Flicker – PLT (Long Term)
  • Memory – 2GB Memory Expandable upto 32GB
  • IEC 61010, CAT IV 600V
  • Auto CT recognition, CT/PT ratios are field programmable
  • 12 Screen shots can be captured
  • Storage Capacity for a selection of parameter s 1s interval
  • Simultaneous data logging and harmonic analysis
  • Complete freedom to select time interval and duration
  • DataView software for download and report generation
  • Phasor diagram with Phase Angles
Measurements:
  • AC/DC Voltage & AC/DC Current
  • W, VA, VAr, VAD, Wh, VAh, VArh, Dh
  • Peak V & I values and Peak Factor
  • Frequency – 50 & 60 Hz
  • FHL, K factor, PST, PF, Cosø, Tanø, DPF
  • THDf on V & I, Harmonics up to 50th order

KRYKARD ALM 31

Salient features:
  • 3 Voltage & 3 Current channel (Neutral Current)
  • IEC 61010, CAT IV 600V
  • Auto CT recognition, CT/PT ratios are field programmable
  • 12 Screen shots can be captured
  • Storage Capacity for a selection of parameter 1s interval
  • Simultaneous data logging and Harmonic analysis
  • Complete freedom to select time interval and duration
  • DataView software for download and report generation
  • Phasor diagram with Phase Angles
Measurements:
  • AC/DC Voltage & AC/DC Current
  • W, VA, VAr, VAD, Wh, VAh, VArh, Dh
  • Peak V & I values and Peak Factor
  • Frequency – 50 & 60 Hz
  • FHL, K factor, PST, PF, Cosø, Tanø, DPF
  • THDf on V & I, Harmonics up to 50th order

KRYKARD ALM 20

Salient Features:
  • 3 Voltage & 3 Current Channel
  • Bluetooth, Ethernet and USB
  • magnetic Latch for instant Mounting
  • Removable SD card
  • Self-powered, no dependence on battery
  • IEC 61010, CAT IV 600V
  • Auto CT recognition, accepts up to 8 different CTs
  • Data logging & data retrieval possible directly from SD card
  • Simultaneous data logging & harmonic analysis
  • Complete freedom to select time interval & duration
  • DataView software for download & report generation
Measurements
  • Voltage, Current
  • Frequency – 50, 60 & 400 Hz
  • kW, kVA, kVAr(with & without Harmonics)
  • Wh, VAh, VArh, PF, Cosø, Tanø
  • Short-term Flicker, Crest Factor, K-Factor
  • THDf on V & I, Harmonics up to 50th order

Current Transducers

Specification Ampflex A193
450 mm
Ampflex A193
800 mm%
MN 93 MN 93A
Dia(mm) 140 250 20 20
Maximum
Current
10,000Aac 10,000Aac 240Aac Dual range 5Aac &
100Aac
Range 100mA to 10,000Aac (measures
from 10A when used onALM10)
1A to 200Aac 5mA to 5Aac
/ 100mA to
100Aac
Accuracy ±2% ±2% ±2% ±0.7%
Safety CAT IV 600V/
CAT III1000V
CAT IV 600V/
CAT III1000V
CAT IV 600V/
CAT III 1000V
CAT IV300V/
CAT III600V

Specification PAC 93 C193 J93  E3N
Dia(mm) 39 52 72 11.8
Maximum
Current
  1000Aac/
1300Adc
10,00Aac 3,500Aac/
5000Adc
100Aac/dc
Range 1A to
1,000Aac/
1A to 1300Adc
1A to 1,000Aac 50A to
3,500Aac/
50A to
5,000Adc
10mA to
100mAac/dc
Accuracy ±3% ±0.2% ±1% ±1%
Safety CAT IV 300V/
CAT III 600V
CAT IV 600V CAT IV300V/
CAT III600V
CAT IV300V/
CAT III600V

I-Flex 450 ( Suitable for ATEST Clamp Meter)

CLD 600 (Suitable for ATEST and KRYKARD Meter

Specification I-Flex 450 CLD 600
Dia(mm) 140 36
Maximum
Current
3000 A 600A (AC,DC)
Range 30 A, 300A, 3000 A 0.1 A … 100A / … 600A
Accuracy  ±3% ±2%
Safety 1000 V CAT III, 600 V CAT IV Cat. III 600V, Cat. II 1000V

CLASS- A Power Quality Analyser

Introduction:

The Dranetz HDPQ® family of Power Quality, Demand and Energy instruments is the latest in a long line of industry leading products from Dranetz. The Dranetz HDPQ instruments are: Visa, Guide, Xplorer

Features:

  • Class – A Compatible to Ed-3 as per IEC 61000-4-30
  • 0.2s Class accurcy
  • Multitasking – Log simultaneously RMS, Harmonics, Transient and other PQ events
  • 7-Inch Wide Screen Color, touch LCD
  • 4 isolated Voltage & Current channels
  • 4 AC/DC Current Channels with Flex probe
  • Fully Compatible with Dran-View 7
  • Harmonics – IEC 61000-4-7, IEEE 519 (2014)
  • 4GB Internal Flash Memory. External Storage Via USB
  • IEEE 1459 Advanced Power measurements

RMS Measurements:

  • AC/DC Voltage & AC/DC Current
  • High Definition PQ & Energy Monitoring – 1000Vrms, AC/DC, 512 samples/cycle
  • KW, kVA, kVAr, VAD, Wh, VAh, VArh, Dh
  • Peak V & I values and Peak Factor

Harmonics:

  • Harmonics, Interharmonics, Mains Signaling
  • total Harmonic Distortion – Voltage , Current
  • total InterHarmonics Distortion – Voltage, Current

PQ Events:

  • Sag/Dip, Swell, Transients, Rapid Voltage Change, Waveform disturbance
  • Transient capabilities – V & I waveshape triggers. Well beyond standards requirements
  • Inrush with 130 cycles in VISA, 10k Cycle GUIDE and XPLORER
  • 100 cycle pre/post trigger buffer (HDPQ VISA)
  • 10,000 cycle pre/post trigger buffer (GUIDE & XPLORER)
  • High Speed Digitized Transients 32μs/40μs Transients and 1μs in XPLORER

Other PQ Events:

  • Unbalance – positive and negative sequence
  • Flicker-short term & Long Term
  • FHL, K factor

Communication:

  • Ethernet, 802.11 Wireless, Bluetooth, USB
  • Apps for Apple, android Tablets & Smartphones
  • Vnc Remote Control For PC, Mac, IOS & android
  • Gps, Ntp, Internal Time Synchronization

Other Features:

  • AnswerModules – Sag directivity, PF capacitor identification, motor-automatic event categorization (GUIDE & XPLORER)
  • Easy-to-Use with Automatic or Manual Setups
  • Rugged IP50 Enclosure with Easel & Cable Management
  • Universal Power Supply with Multi-Country Plugs
Parameter Range  Accuracy %
Voltage AC/DC 0-1000Vrms, <40V 0.5%FS ±0.1
Current AC/DC Range probe dependent ±0.5
Power W,VA,VAr,Demand in W, Wh ±0.2
Power Factor (W/VA) -”true” -1 to 0 to +1 1
PDF -1 to 0 to +1 1
Vthd 0-100%, for V>=10% Vnom ±5
V Individual 2-127, for V>=10% Vnom ±5
I thd 0-100%, for I>=10% Inom ±5
I Individual Harm DC, 2-63, for I>=10% Inom ±5
Short Time Flicker 10 minutes: 0.2-10,@ Pst=1 ±5
Long Time Flicker 2 hours: 0.2-10, @ Pst=1 ±5

Features

  • Range: 0.5 A to 3000A/ ± 1%
  • Dia: 450mm
  • Range: 6A to 6000A / ± 1%
  • Dia: 450mm

Features

  • Range: 15A to 150A/ ± 1%
  • Dia: 52mm

Software

DATAVIEW for KRYKARD ALM xx

Features:
  • Recovery of the measurement data
  • Stored in the instrument
  • Backup of measurement files
  • Opening of backup files
  • Processing and creation of reports
  • Export into Excel spreadsheets
  • Export in .pdf format
  • Database management

The measurements taken can also be processed by the multi-product expert processing software

  • It automatically recognizes the instrument when it is hooked up to the PC and opens the corresponding menu.
  • It includes numerous predefined report templates for quick report generation in accordance with the applicable standard



Dran-View 7 for Dranetz

Dran-view 7 software is a Windows based software package that enables power professionals to simply and quickly
visualize and analyze power quality/energy monitoring data. Now in its 7th major revision, Dran-View 7 offers the powerful
feature set that you expect from Dran-View, but now it has a more modern appearance and a simpler user interface. Also, Dran-View 7 is a true 64 bit program that can take full adavantage of the speed and file size capabilities the latest computer/Windows Operating Systems, but remains compatible with older 32 bit computers.

Reporting:
  • Automated reporting.
  • Design Custom Reports.
  • Edit Reports.
Visualization:
  • Three pan Window.
  • AnswerModules.
  • Tailored Presentation option.
Analysis:
  • Events catergorized, Stored and grouped.
  • Evaluate Data from Various formats.
  • Harmonics tools.


Advantages:

Setup installation errors can be corrected even after the data has been recorded, to include the following:

  • Adjust timestamps.
  • Invert Current probes.
  • Change scaling factors.
  • Change connection type.

Other Product Range from PCE division

ONLINE UPS

  • IGBT Inverter with Inverter Isolation Transformer
  • 10 to 500 KVA 3 phase On-line Double Conversion
  • Output PF @0.9 for more power delivery
  • High efficiency
  • smaller Foot print ~ 10% – 20% less than others
  • Adjustable Batteries count: 29 to 32 (<120KVA) and 48 to 52 (>150KVA)

IoT SERVO STABILISERS – FOR YOUR FACTORY

  • Factory Incomer
  • Factory Departments
  • Group Load Incomer
  • Commercial Building Incomer
  • Hospital & Hotel Incomer

SERVO Voltage STABILISERS

  • 30 year experience
  • Microprocessor based control
  • VAF display
  • Comprehensive protection
  • Preferred supplier for corporate customers
  • Upto 4000kVA rating

ISOLATION TRANSFORMERS

  • Upto 500kVA rating
  • Galvanic and Ultra Isolation Transformers
  • Step-down and Step-up Transformers

ACTIVE HARMONIC FILTERS

  • Mitigate harmonics upto 50th order
  • Improve PF to 0.99 and above
  • Avoid Penalties from EB
  • Minimise machinery failures due to harmonics
  • Increase Transformer utilisation factor

Other Product Range from EMS Division

PANEL LOAD MANAGERS

  • Accuracy Class 0.2s, 0.5s and 1.0
  • Meters for Incomers, Feeders and Loads
  • Accuracy maintained under low Current, low PF and high harmonic load conditions
  • Meters with Load Management functions
  • PQ meters, Demand Controllers, Energy Meters, Load-end meter

ENERGY MANAGEMENT SYSTEM

  • A Live Energy Auditor – helps you identify, measure &
  • Advise you of Electrical Load Balancing, machine side
  • Losses, Specific Energy Consumption, Productivity analysis & overall process/plant efficiency
  • Powerful platform for managing and optimising resources for any type of industry
  • Connect hundreds of energy, water, air or gas meters to a
  • single consolidated system

CLOUD BASED ENERGY MANAGEMENT SYSTEM

  • A Mobile Energy Auditor “on the go”- helps you with faster & quick energy consumption analysis and enable you to take action by way of user friendly KPI dashboards
  • A perfect solution for small factories, buildings and retail outlets Built to view data across multiple remote sites
  • iOS and android mobile apps for anywhere, anytime access and alert notification

LIGHTING ENERGY SAVERS

  • Saves upto 25% on lighting loads
  • Works effectively on Tubelights, Sodium Vapour, Mercury, Vapour, CFL
  • Reduces failures in lighting
  • Improves PF and reduces Demand
  • Drastic reduction in Harmonics and ballast induced spikes
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “PORTABLE TEST & MEASUREMENT INSTRUMENTS”

Your email address will not be published. Required fields are marked *

Request For Offer
× How can I help you?