Atandra Energy Pvt. Ltd. is a Chennai based company built on a platform of over 30 years experience in the area of Power & Energy Management.
We offer solutions to industrial and commercial establishments under our popular brand KRYKARD. with over 4,00,000 installations of Power Conditioners and over 1,50,000 installations of Portable and Panel Load Managers, KRYKARD is one of the leading brands in the area of Power Conditioning & Energy Management.
ATEST is our new brand for Test & Measurement products to meet the growing expectations of industry for performance oriented T&M products that meet the expanding needs and have multilayered offering of specifications, performance and price. The ATEST range of T&M products meet all key applications and needs of industry, auditors and OEMs.
We have the following in-house facilities:
With around 300 employees and a network of branches across the country, we are well equipped to reach and service the needs of our customers.
Certain niche and high-end models of our range are imported from our foreign principals. Atandra markets these products and provides technical, application and service support to these products in India.
Founded in Paris, in 1893, CHAUVIN ARNOUX is a major player in the measurement market in France and internationally.
Metrix is a group of Chauvin Arnoux- specialized by manufacturing industrial, laboratory and educational instrumentation.
For more than 50 years, Dranetz has been the leading provider of intelligent monitoring solutions for electrical demand a energy and power quality.
Parameter | Range | Accuracy % |
---|---|---|
ACMA | 60mA/600mA | 2 |
AC Current | 10A/100A | 2 |
DC Voltage | 600v | 1 |
AC Voltage | 600v | 1.2 |
Frequency | 1000Hz | 0.1 |
Resistance | 1000Ω | 1 |
Parameter | Range | Accuracy % |
---|---|---|
AC Current | 6mA/100A | 1 |
Parameter | Range | Accuracy % |
---|---|---|
DC Current | 300mA/3000mA/10A | 1 |
AC Current | 300mA/3000mA/20A | 1 |
DC Voltage | 50V/300V | 1 |
AC Voltage | 50V/300V | 1 |
Resistance | 500Ω/5KΩ/50KΩ/500KΩ | 1 |
Resistance | <1000Ω |
Parameter | Range | Accuracy % |
---|---|---|
AC Current | 40A/400A | 1.9 |
AC Voltage | 400V/600V | 1.2 |
DC Voltage | 400V/600V | 1 |
Resistance | 400Ω | 1 |
Continuity | <25Ω |
Parameter | Range | Accuracy % |
---|---|---|
AC Current | 40A/400A | 1.9 |
AC Voltage | 1000V | 1.2 |
DC Voltage | 1000V | 0.3 |
Resistance | 10KΩ | 0.9 |
Continuity | < 25Ω |
Parameter | Range | Accuracy % |
---|---|---|
DC Current | 40A/ 400A | 1.5 |
AC Current | 40A/ 400A | 1.5 |
DC Voltage | 400V/ 600V | 0.7 |
AC Voltage | 400V/ 600V | 0.9 |
Resistance | 400Ω~40MΩ | 0.9 |
Frequency | 40Hz~40KHz | 0.3 |
Diode | 3.1V max | |
Continuity | <50Ω, 2KHz tone buzzer |
Parameter | Range | Accuracy % |
---|---|---|
AC Current | 60A/600A | 1.9 |
AC/DC Voltage | 6V/60V/600V | 1 |
Resistance | 600Ω~6MΩ | 1.2 |
Capacitance | 6nF/600uF | 3 |
Frequency(A) | 6KHz/10KHz | 0.2 |
Frequency(V) | 6KHz/60KHz/100KHz | 0.2 |
Diode | 0 ~ 1.2V | |
Continuity | < 30Ω |
Parameter | Range | Accuracy % |
---|---|---|
AC Current | 400A, 600A | 1.9 |
DC Voltage | 400V, 600V | 0.9 |
AC Voltage | 400V, 600V | 1.5 |
Resistance | 400Ω | 1 |
Frequency | 4KHz, 10KH | 0.1 |
Diode | 3.3V max | |
Continuity | <30Ω |
Parameter | Range | Accuracy % |
---|---|---|
DC Current | 60A, 600A | 1.5 |
AC Current | 60A, 600A | 1.9 |
DC Voltage | 600V | 0.7 |
AC Voltage | 600V | 1.5 |
Resistance | 600Ω~40MΩ | 0.9 |
Frequency | 100 Hz … 50 kHz | 1 |
Diode | 1.500V | 1.5 |
Continuity | <20Ω, 2.7KHz tone buzzer |
Parameter | Range | Accuracy % |
---|---|---|
AC Current | 600A/1000A | 1.9 |
AC Voltage | 6V/60V/600V | 1.2 |
DC Voltage | 6V/60V/600V | 1 |
Resistance | 600Ω/6KΩ/600KΩ | 1 |
Parameter | Range | Accuracy % |
---|---|---|
AC Current | 400A, 1000A | 1.9 |
DC Current | 400A, 1000A | 1 |
AC Voltage | 400V, 750V | 1 |
DC Voltage | 400V, 1000V | 1 |
Resistance | 400Ω | 1 |
Frequency | 20Hz~400Hz | 0.1 |
Diode | 3V max | |
Continuity | <30Ω, 2KHz tone buzzer |
Parameter | Range | Accuracy % |
---|---|---|
AC Current | 100A, 1000A | 1.5 |
DC Current | 100A, 1000A | 1.5 |
ACA Via SFLEX | 0.1A~3000A | |
AC Voltage | 100V, 1000V | 1 |
DC Voltage | 100V, 1000V | 1 |
AC+DC Voltage | 100V,1000V | 1 |
Resistance | 100KΩ | 1 |
Watt | 10KW~1MW | 2.5 |
THD | 0.1%~100% | 3 |
Harmonics | 0.1%~100% | 0.1 |
Frequency | 20.0Hz~10KHz | 0.5 |
Parameter | Range | |||||
---|---|---|---|---|---|---|
Models | F205 | F407 | F607 | |||
Clamp Dia | 34mm | 48mm | 60mm | |||
Type | [AC, AC+DC]/DC | |||||
Voltage | 0.15 to 1,000 V | |||||
Current | 0.25 to 600 A | 0.25 to 1,000 A | 0.25 to 3,000 A | |||
Resistance | 60KΩ | 100kΩ | 100kΩ | |||
Diode Test | Yes | No | No | |||
THDf / THDr | Yes | |||||
Power | Yes | |||||
Continuity | Yes | |||||
Recording | NO | Yes,Bluetooth | Yes,Bluetooth |
Parameter | Range |
---|---|
Display | Backlit LCD |
Loop ohmmeter | 0.010 to 1500 |
measurement Frequency |
2083 Hz |
Transposition frequency |
50, 60, 128 or 2,083 Hz |
Loop inductance | 10μH to 500μH |
Ground Voltage | 0.1V to 75V |
Ammeter | 0.200mA to 39.99A |
Others | Alarms,Buzzer,Hold,Automatic power- off |
Weight | 55 x 95 x 262 mm/ 935gm |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 2V ~ 750V | 1 | |
AC Voltage | 1V ~ 750V | 1.3 | |
Resistance | 0Ω ~ 2000Ω | 2 | |
Frequency Counter | 30Hz ~ 999Hz | 0.3 | |
Diode Test | 0.3V ~ 0.9V | 0.9 | |
Single Phase Test V | 100V ~ 750V AC | ||
Single Phase Test Hz | 45Hz ~ 65Hz | ||
Rotary Field Indication V |
100V ~ 750V AC | ||
Rotary Field Indication Hz |
50Hz ~ 60Hz |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 400.0mV ~ 600V | 0.6 | |
AC Voltage | 400.0mV ~ 600V | 0.9 | |
Resistance | 400.0Ω ~ 40.00MΩ | 0.9 | |
Capacitance | 50nF ~ 100uF | 2.9 | |
Frequency Counter | 5Hz ~ 5MHz | 0.3 | |
Duty Cycle | 0.1% ~ 99.9% | 0.3 | |
Diode Test | Open circuit Voltage: 1.5V | ||
Continuity Beeper | <30 Ω , 2KHz tone buzzer |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 6V, 60V, 600V | 0.5 | |
AC Voltage | 6V, 60V, 600V | 1 | |
DCmV | 600mV | 0.5 | |
Resistance | 600Ω~40MΩ | 0.5 | |
Capacitance | 50nF~1000μF | 2 | |
Frequency Counter | 100Hz~50KHz | 0.1 | |
Diode Test | 1.500V | 1 | |
Continuity Beeper | <30Ω, 2.7KHz tone buzzer |
Parameter | Range | Accuracy % |
---|---|---|
DC Voltage | 6V, 60V, 600V | 0.5 |
AC Voltage | 6V, 60V, 600V | 1 |
DCmV | 600mV | 0.5 |
ACA, DCA | 6A, 10A | 1.5 |
DCμA | 400µA, 4000µA | 0.9 |
Resistance | 600Ω~40MΩ | 0.5 |
Capacitance | 50nF~1000μF | 2 |
Frequency Counter | 100Hz~50KHz | 0.1 |
Diode Test | 1.500V | 1 |
Parameter | Range | Accuracy % |
---|---|---|
DC Voltage | 6V, 60V, 600V | 0.5 |
AC Voltage | 6V, 60V, 600V | 1 |
DCmV | 600mV | 0.5 |
ACA, DCA | 6A, 10A | 1.5 |
DCμA | 400µA, 4000µA | 0.9 |
Resistance | 600Ω~40MΩ | 0.5 |
Capacitance | 50nF~1000μF | 2 |
Frequency Counter | 100Hz~50KHz | 0.1 |
Temperature | -40°C ~ 400°C | 1 |
Diode Test | 1.500V | 1 |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 60mV ~ 1000V | 0.5 | |
AC Voltage | 60mV ~ 1000V | 1 | |
DC Current | 6A/10A | 1 | |
AC Current | 6A/10A | 1.5 | |
Resistance | 600Ω ~ 40MΩ | 0.8 | |
Capacitance | 10nF ~ 10mF | 1.9 | |
Frequency Counter | 6kHz ~ 100kHz | 0.1 | |
Diode Test | 1.8V | ||
Continuity Beeper | <30Ω, 2kHz tone Buzzer |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 60mV ~ 1000V | 0.5 | |
AC Voltage | 60mV ~ 1000V | 1 | |
DC Current | 6A/10A | 1 | |
AC Current | 6A/10A | 1.5 | |
Resistance | 600Ω ~ 40MΩ | 0.8 | |
Capacitance | 10nF ~ 10mF | 1.9 | |
Frequency Counter | 6kHz ~ 100kHz | 0.1 | |
Temperature | – 40°C ~ 400°C | 1 | |
Diode Test | 1.8V | ||
Continuity Beeper | <30Ω, 2kHz tone Buzzer |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 600mV, 1000V | 0.5 | |
AC Voltage | 600mV, 1000V | 1 | |
Auto-V LoZ | 600V, 1000V | 2 | |
Resistance | 600Ω~40.00MΩ | 0.9 | |
Capacitance | 1.000μF~10.00mF | 1.9 | |
Frequency Counter | 100Hz~100KH | 0.1 | |
Diode Test | 1.500V |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 600mV, 1000V | 0.5 | |
AC Voltage | 600mV, 1000V | 1 | |
Auto-V LoZ | 600V, 1000V | 2 | |
DC μA | 600μA | 2 | |
AC μA | 600μA | 1.5 | |
Resistance | 600Ω~40MΩ | 0.9 | |
Capacitance | 1μF~10mF | 1.9 | |
Frequency Counter | 100Hz~100KHz | 0.1 | |
Temperature | -40°C~400°C | 1 | |
Diode Test | 1.500V |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 600mV, 1000V | 0.5 | |
AC Voltage | 600mV, 1000V | 1 | |
Auto-V LoZ | 600V, 1000V | 2 | |
DC Current | 6A, 10A | 1 | |
AC Current | 6A, 10A | 1.5 | |
Resistance | 600Ω~40MΩ | 0.9 | |
Capacitance | 1μF~10mF | 1.9 | |
Frequency Counter | 100Hz~100KHz | 0.1 | |
Diode Test | 1.500V |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 600mV, 1000V | 0.08 | |
AC Voltage | 60mV, 1000V | 0.8 | |
Auto V-LoZ | 600V, 1000V | 0.8 | |
DC Current | 60mA, 10A | 0.8 | |
AC Current | 60mA, 10A | 1.2 | |
Resistance | 600Ω~40MΩ | 0.8 | |
Capacitance | 1μF~10mF | 1.2 | |
Frequency Counter | 100Hz ~ 100KHz | 0.1 | |
Temperature | -40°C ~ 400°C | 1 | |
Diode Test | 1.8V max |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 40mV to 1000V | 0.03 | |
ACV & (AC+DC)V | 40mV to 1000V | 0.7 | |
DC Current | 40mA to 10A | 0.2 | |
ACA & (AC+DC)A | 40mA to 10A | 0.8 | |
Resistance | 400Ω to 40MΩ | 0.2 | |
Capacitance | 4nF to 40mF | 0.9 | |
Frequency Counter | 40Hz to 4MHz | 0.002 | |
Duty Cycle | 20% to 80% | 0.1 | |
Temperature | -200℃ to 1200℃ | ||
Diode Test | Open Circuit Voltage:±3V |
Parameter | Range | Accuracy % | |
---|---|---|---|
DC Voltage | 40mV to 1000V | 0.015 | |
ACV & (AC+DC)V | 40mV to 1000V | 0.7 | |
DC Current | 40mA to 10A | 0.2 | |
ACA & (AC+DC)A | 40mA to 10A | 0.8 | |
Resistance | 1000Ω to 40MΩ | 0.025 | |
Capacitance | 4nF to 40mF | 0.8 | |
Frequency Counter | 40Hz to 4MHz | 0.002 | |
Duty Cycle | 20% to 80% | 0.1 | |
Temperature | -200℃ to 1200℃ | ||
Diode Test | Open Circuit Voltage:±3V |
Parameter | Range | Accuracy % | |
---|---|---|---|
Display | Backlit LCD | ||
AC Voltage | 0.6 V to 750V | 0.5 | |
DC Voltage | 0.6 V to 1000V | 0.2 | |
AC/DC Current | 10 μA to 10 A | 0.5 | |
Resistance | 1 Ω to 60 MΩ | 0.5 | |
Capacitance | 1 nF to 100 mF | 2 | |
Temperature with K- thermocouple |
-55 to +1 200 °C | 2 | |
Weight | 170 x 80 x 50 mm / 320 g |
Parameter | Range | ||
---|---|---|---|
Models | C.A 5273 | C.A 5275 | C.A 5277 |
DC Voltage | 1000V | ||
DCV accuracy | 0.2% | 0.09% | |
AC Voltage | 1000V | ||
AC Current | 6 A / 10 A | 6000 µA to 10 A | |
DC Current | 6 A / 10 A | 6000 µA to 10 A | |
Resistance | 600 Ω to 60 MΩ | ||
Frequency | 600 Hz to 50 kHz | ||
Capacitance | 6 nF to 60 mF | ||
Temperature | -59.6to 1200 °C | NA | -59.6 to 1200 °C |
Parameter | Range | |||
---|---|---|---|---|
Model | MTX 3290 | MTX 3291 | MTX 3292 | MTX 3293 |
DC,AC & AC+DC Voltage | 60 mV to 600 V | 60 mV to 1000 V | 100 mV to 1000 V | |
DC accuracy | 0.3 % | 0.05 % | 0.03 % | 0.02 % |
AC & AC+DC Bandwidth | 20 kHz | 100 kHz | 100 kHz | 200 kHz |
DC,AC & AC+DC Current | 600 µA to 10 A /20 A (30 s max) | 1000 µA to 10 A /20 A (30 s max) | ||
DC accuracy | 0.08 % | 0.01 % | ||
Resistance | 600 Ω to 60 MΩ | 100 Ω to 100 MΩ | ||
Capacitance | 6 nF to 60 mF | 1 nF to 10 mF | ||
Temperature | PT100/1000 ,-200 °C to 800 °C, | |||
PWM filter | 4th-order 300 Hz low-pass filter for measuring on variable speed drives of asynchronous motors | |||
V-output clamp function for direct reading |
Integration of the ratio: 1/1 ,1/10,1/100,1/1000 mV/A | Parameterizable Ax ratio |
Parameter | Range | Accuracy % | |
---|---|---|---|
Inductance | 20μH~20KH | 0.2 | |
Capacitance | 20pF~20mF | 0.2 | |
Resistance | 20Ω~200MΩ | 0.2 | |
DC Resistance | 200Ω~200MΩ | 0.2 | |
Q | 0.000~2000 | ||
D | 0.000~2000 | ||
θ | ±90° |
Parameter | Range | Accuracy % | |
---|---|---|---|
Inductance | 0.001μH~2000mH | 0.2 | |
Capacitance | 0.01pF~200μF | 0.2 | |
Resistance | 0.001Ω~200MΩ | 0.2 | |
DC Resistance | 0.01Ω~200MΩ | 0.2 | |
Q | 0.000~1999 | ||
D | 0.000~1999 | ||
θ | ±90° |
Parameter | Range | Accuracy % |
---|---|---|
Inductance | 0.001μH~2000mH | 0.2 |
Capacitance | 0.01pF~200μF | 0.2 |
Resistance | 0.001Ω~200MΩ | 0.2 |
DC Resistance | 0.01Ω~200MΩ | 0.2 |
Q | 0.000~1999 | |
D | 0.000~1999 | |
θ | ±90° |
Parameter | Range | |||
---|---|---|---|---|
Models | OX 5022 | OX 5042 | ||
Bandwidth | 20 MHz | 40 MHz | ||
Bandwidth Limiter | 1.5MHz, 5kHz | |||
Sampling rate | Automatic, Triggered, one shot | |||
Memory Depth | 2500 points | |||
AC,DC&AC+DC Voltage | 600 mV to 600 VRMS | |||
Resistance | 80 Ω to 32 MΩ | |||
Capacitance | 5 nF to 5 mF | |||
Harmonic analysis | 31st orders, freq from 40 to 450Hz | |||
Weight | 214x110x57mm / 1.2 kg |
Parameter | OX 9062 | OX 9102 | OX 9104 | OX 9304 | ||
---|---|---|---|---|---|---|
Models | ||||||
Number of Channels | 2 isolated channels | 4 isolated channels | ||||
Bandwidth | 60 MHz | 100 MHz | 100 MHz | 300 MHz | ||
Input impedance | 1 MΩ ± 0.5% , approx. 12 pF | |||||
Maximum sampling rate | 2.5 GS/s in one-shot mode on each channel | |||||
Memory depth | 100 kpts per channel and file viewer in the manager | |||||
AC, DC& AC + DC Voltage | 600 mV to 600 VRMS, 800 mV to 800 VDC – VDC accuracy +/- (0.5 % + 25 D) – 200 kHz bandwidth | |||||
Harmonic analysis | 2 or 4 (depending on model), 63rd orders, fundamental frequency 40 to 450 Hz in auto or manual mode | |||||
Resistance/Capacitance | 80 Ω to 32 MΩ / 5nF to 5mF | |||||
Frequency | 200 kHz | |||||
Single and three-phase power | Active, Reactive and Apparent power values plus Power Factor simultaneously with the U & I measurements | |||||
Logger | Duration: 20,000 s – Interval: 0.2 s – Files: 1,00,000 measurements | |||||
PC communication – software link |
Ethernet (100 baseT), WiFi-USB (device, 12 Mbs) – “ScopeNet” application software for PC |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
DC Voltage | 600V | 1 | ||
AC Voltage | 600V | 1.5 | ||
Earth Bond Resistance |
40Ω ~ 40kΩ | 1.5 | ||
Test Voltage | 50V, 100V, 250V, 500V, 1000V | |||
Insulation Resistance | 0.001M Ω ~ 20.0GΩ | 1.5 | ||
Continuity | under 200mA |
Parameter | Range | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Models | C.A 6522 | C.A 6524 | C.A 6526 | C.A 6532 | C.A 6534 | C.A 6536 | |||||
Voltage / Accuracy | 0.3 V – 700 V / 3% | ||||||||||
Frequency | 15.3 Hz – 800 Hz | ||||||||||
Insulation Test Voltage | 250-500 -1000 V | 50 – 100 – 250 – 500 – 1000 V | 50 – 100 V | 10- 25 – 100 – 250 – 500 V | 10 V to 100 V in 1 V steps | ||||||
Range at maximum test Voltage | 40 GΩ | 200 GΩ | 20 GΩ | 50 GΩ | 20 GΩ | ||||||
Display of test Current | – | 0.01 µA – 39.99 µA / 10 nA; 40.0 -399.9 µA / 100 nA; 0.400 -2.000 mA/ 1 µA | |||||||||
Accuracy of test Current | ± (10 % + 3 cts) | ||||||||||
PI/DAR ratios | NA | 10 min / 1 min – 1 min / 30 s | NA | NA | |||||||
Continuity | 0.00 Ω-10.00 Ω (200 mA) | 0.00 Ω-10.00 Ω (200 mA); 0.0 -100.0 Ω (20 mA) | |||||||||
measurement Current | 200 mA range: 200 mA (-0 mA +20 mA); 20 mA range: 20 mA ± 5 mA | ||||||||||
Resistance range / Resolution / Accuracy |
NA | 0 -3999 Ω / 1 Ω; 4.00 kΩ – 39.99 kΩ / 10 Ω / ± (3 % + 2 cts) 40.0 kΩ – 399.9 kΩ / 100 Ω; 400 kΩ-1000 kΩ / 1 kΩ / ± (3 % + 2 cts) |
|||||||||
Capacitance range / Resolution |
NA | NA | 0.1 nF -399.9 nF / 0.1 nF 400 nF -3999 nF / 1 nF 4.00 µF -10.0 µF / 10 nF | NA | NA | ||||||
Storage | NA | 300 measuremen | 1300 measurements | NA | |||||||
Communication | NA | NA | Bluetooth® Class II | NA |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Temperature°C | -30°C ~ 500°C | 1 | ||
Temperature°F | -22°F ~ 932°F | 1.5 | ||
Response Time | 0.5 sec | |||
Distance to Spot | 8:1 | |||
Spectral Response | 6.5um ~ 18um | |||
Emissivity | 0.95 | |||
Non-Contact Voltage Detection |
60VAC ~ 600VAC |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Temperature°C | -20~500°C | 2 | ||
Temperature°F | – 4~932°F | 2 | ||
Response Time | 500m Sec | |||
Distance to Spot | 8:1 | |||
Emissivity | Pre-Set at 0.98 |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Temperature°C | -20~500°C | 2 | ||
Temperature°F | – 4~932°F | 2 | ||
Response Time | 500m Sec | |||
Distance to Spot | 12 : 1 | |||
Emissivity | Pre-Set at 0.98 |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Temperature°C | -35 °C to + 450 °C | 2 | ||
Temperature°F | -31°F to + 842°F | 2 | ||
Response Time | 250 ms | |||
Distance to Spot | 10 : 1 | |||
Emissivity | 0.95 |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Temperature°C | – 35 °C to + 650 °C | 2 | ||
Temperature°F | -31 °F to + 1202°F | 2 | ||
Response Time | 250 ms | |||
Distance to Spot | 12 : 1 | |||
Emissivity | adjustable from 0.1 to 1.0 |
Parameter | Range | |||
---|---|---|---|---|
Models | TCA 1950 | TCA 1954 | ||
Detector | 80 × 80 | 160 × 120 | ||
Frequency | 9 Hz | |||
Temperature | -20°C to +250°C | |||
Thermal Image performance | ||||
Field of View | 20° x 20° | 38° x 28° | ||
IFOV | 4.4 mrad | 4.1 mrad | ||
Min Focal Distance | 40cm | 30cm | ||
functions for Analysis | ||||
Vocal comments | Yes via Bluetooth (earphones provided) | |||
Display Image | Thermal Image / Real Image | |||
Image format | .bmp | .png | ||
Battery | NiMH recharegeable Batteries |
The RayCAm Report standard software is equipped with a very simple user interface allowing:
RayCAm Report standard allows you to define the emissivity of each point in the thermogram, an essential feature when the thermogram contains different materials.
Parameter | Range | |||
---|---|---|---|---|
Models | C.A 6131 | C.A 6133 | ||
Continuity | 0.00 to 9.99 Ω | |||
Resistance | 1 to 9999 Ω | |||
Insulation | 250 V / 500 V | 250 V/500 V/ 1000 V | ||
Earth res- 3P | NA | 0.50 to 2000 Ω | ||
Frequency | NA | 30.0 to 999.9 Hz | ||
Current | Via clamp with Voltage output |
Via MN73A clamp | ||
Voltage | 0 – 800V | |||
RCD test (V) | 90 to 450 V | |||
Trip time | 0.5 x I ΔN ; 1 x I ΔN ; 5 x I ΔN / 5.0 to 300 ms |
Parameter | Range | |||
---|---|---|---|---|
Models | C.A 6541 | C.A 6543 | ||
Voltage | 1 to 1000 VAC/DC | |||
Insulation | 50 / 100 / 250 / 500 / 1000 VDC | |||
Range | 2 kΩ to 4 TΩ | |||
Continuity | 0.01 to 40 Ω | |||
Resistance | 0.01 to 400 kΩ | |||
Capacitance | 0.005 to 4.999 μF | |||
Storage | NA | 128 kB | ||
PC software | NA | Dataview® (option) |
Parameter | Range | |||
---|---|---|---|---|
Models | C.A 6505 | C.A 6545 | C.A 6547 | C.A 6549 |
Voltage | 1 to 5100 V AC/DC | |||
Insulation | 500/1000/ 2500 / 5000 VDC + variable from 50 V to 5100 VDC (10 or 100 V increments) |
|||
Range | 10 kΩ to 10 TΩ | |||
Capacitance | 0.001 to 49.99 μF | |||
Current | 0.001 nA to 3000 μA | |||
Voltage ramp | NA | 5 steps | ||
Quality ratios | DAR / PI | DAR / PI / DD | ||
Storage | 4 kB | 128 kB | ||
PC software | NA | Dataview® (option) |
Parameter | Range | |||
---|---|---|---|---|
Models | C.A 6550 | C.A 6555 | ||
Test Voltages | 10kV | 10kV | ||
Ranges | 10,000 V10 kΩ to 25 TΩ | 10kV | ||
Variable Test Voltages | 40 V – 10,000 V | 10kV | ||
Ramp mode | start Voltage/ endVoltage/duration | |||
Step mode | Up to 10 steps | |||
Capacitance | 0.001-9.999 µF / 10.00-49.99 µF | |||
Leakage Current | 0 – 8 mA | |||
Weight | 340 x 300 x 200 mm, 6.2 kg |
Parameter | Range | |||
---|---|---|---|---|
Models | C.A 6460 | C.A 6462 | ||
3PMethod Range | 0.01 to 2000Ω | |||
Frequency | 128Hz | |||
4PMethod Range | 0.01 to 2000Ω | |||
Resolution 3P/4P | 10 mΩ/ 100mΩ/1Ω | |||
Resistivity | 0.01 to 99.9kΩ | |||
Measurement | 4500 measurement of 15 s | 4500 measurement of 15 s |
Parameter | Range | |||
---|---|---|---|---|
Models | C.A 6470N | C.A 6471 | ||
3PMethod | 0.01 Ω to 99.9 kΩ | |||
4PMethod | 0.001 to 99.99 kΩ | |||
Earth measurement with 2 clamps | NA | 0.01 to 500 Ω | ||
Resistivity | 0.01 to 99.9 kΩ | |||
DC resistance | 0.12 Ω to 99.9 kΩ | 0.001 Ω to 99.9 kΩ |
Parameter | Range | |||
---|---|---|---|---|
Specifications | C.A 6472 & C.A 6474 | |||
measurements | Earth,Selective earth, Resistivity, Coupling, Continuity, Pylon earth (with C.A 6474) | |||
Type | 3P/4P/4P with clamp/ 2 calmps | |||
Meas range | 0.001 to 100KΩ ( automatic ranging) | |||
No load Voltage | 16V or 32 V ( as required) | |||
Frequency | 41 Hz to 5078 Hz | |||
Rod Resistance | 0.12 Ω to 99.9 kΩ | |||
U disturbance | 0.12 Ω to 99.9 kΩ | |||
Noise Rejection | 0.12 Ω to 99.9 kΩ | |||
Weight | 272x250x128 mm 3.2 kg / C.A 6474: 2.3 kg |
Parameter | Range | |||
---|---|---|---|---|
Models | C.A 6240/ C.A 6255 | C.A 6292 | ||
Resistance | 0.1 μΩ to 1μΩ | 0.1μΩ to 1Ω | ||
Resolution | 3P/4P/4P with clamp/ 2 calmps | 0.1μΩ to 10μΩ | ||
Accuracy | 0.25% | ± 1% | ||
Measurement Current |
1mA to 10A | Clamp | ||
BSG | NA | Yes | ||
Output Voltage | NA | 110 Vac: 4.2 V 220 Vac: 8.6 V |
||
Weight | 270x250x180mm/4.5Kg |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Ratio Range (VT/PT) | Auto ranging- 0.8000 to 8000 :1 | ±0.1 | ||
Ratio Range (CT) | Auto ranging- 0.8000 to 1000.0 | ±0.5 | ||
Excitation Frequency |
70 Hz | |||
Excitation Current | 0 to 1000 mA | ±2 | ||
Excitation Signal | VT/PT Mode: 32Vrms max CT Mode: Auto Level 0 to 1 A, 0.1 to 4.5V | |||
Measurement Method |
In accordance with IEEE Std C57.12.90™- 2006 |
Parameter | Range | Accuracy % |
---|---|---|
Temperature °C | -30~70°C | 0.7 |
Temperature °F | -22~158 °F | 0.7 |
Humidity | 5%~98%RH | 3 |
Parameter | Range | Accuracy % |
---|---|---|
Temperature °C | -20~60°C | 0.8 |
Temperature °F | -4~140 °F | 1.6 |
Humidity | 0~99%RH | 3 |
Parameter | Range | Accuracy % |
---|---|---|
Temperature °C | -20~60°C | 0.8 |
Temperature °F | -4~140 °F | 1.6 |
Humidity | 0~99%RH | 2.5 |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Temperature °C | – 10.0 to + 60.0°C | 0.5 | ||
Temperature °F | 14.0 to + 140.0°F | 1.6 | ||
Humidity | 3.0 to 98.0 %RH | 2 | ||
Dew Point °C | – 20.0 to + 60.0°Ctd | |||
Dew Point °F | -4.0 to + 140.0 °Ftd |
Parameter | Range | Accuracy % |
---|---|---|
Temperature°C | -200~1370°C | 0.1 |
Temperature °F | -328~2498°F | 0.1 |
Parameter | Range | ||||
---|---|---|---|---|---|
Models | C.A 1821 | C.A 1822 | C.A 1823 | ||
Channel°F | 1 channel J,K,T,N,E,R,S |
2 channels J,K,T,N,E,R,S |
1 channel Pt100, Pt1000 |
||
Range / Resolution |
– 210°C to +1,200°C -346°F to + 3,212°F |
-100 to +400° C -148 to +752 °F |
|||
Resolution | 1°C/1°F | 0.1°C/0.1°F |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Temperature°C | -100~400°C | 0.1 | ||
Temperature°F | -148~752°F | 0.1 | ||
Sampling Rate | 2 time/sec. | |||
Sensor Type | Platinum temperature -measurement resistor (Pt100/4 line type) |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Temperature°C | -100~300°C | 0.1 | ||
Temperature°F | -148~572°F | 0.1 | ||
Sampling Rate | 2 time/sec. | |||
Sensor Type | Platinum temperature-measurement resistor (Pt100/4 line type | |||
Water Resistance | IP67 |
Measurement Range: -50°C to 200°C-58°F to 392°F
tolerances : ±2.2°C (±3.9°F)
Measurement Range: -50°C to 700°C-58°F to 1292°F
tolerances : ±2.2°C (±3.9°F)
Measurement Range: -50°C to 400°C-58°F to 752°F
tolerances : ±2.2°C (±3.9°F)
Measurement Range: -50°C to 600°C-58°F to 1122°F
tolerances : ±2.2°C (±3.9°F)
Measurement Range: -50°C to 400°C -58°F to 752°F
tolerances : ±2.2°C (±3.9°F)
Measurement Range: -50°C to 800°C -58°F to 1472°F
tolerances : ±2.2°C (±3.9°F)
Measurement Range: -100°C to 400°C ; -148°F to 752°F
Accuracy: Class A, ±0.15°C ±0.002t
Temperature sensor Dimension Approx 0.125” Temperature sensor Length: Approx 4.72”
Measurement Range: -100°C to 400°C ; -148°F to 752°F
Accuracy: Class A
Temperature sensor Dimension Approx 0.2” Temperature sensor Length: Approx 9.05”
Parameter | Range | Accuracy % |
---|---|---|
Temperature°C | -20~60°C | 0.8 |
Temperature°F | -4~140°F | 1.5 |
Dew Point °C | -20°C~60°C | 0.8 |
Dew Point °F | -4~140°F | 1.5 |
Humidity | 0~100%RH | 3 |
Parameter | Range | Accuracy % |
---|---|---|
Temperature°C | -20~60°C | 0.8 |
Temperature°F | -4~140°F | 1.5 |
Humidity | 0~100%RH | 2 |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Air Velocity | 0~25 m/s | 3 | ||
Air flow | 0~999900 m3/min | |||
Temperature°C | -20°C~60°C | 0.8 | ||
Temperature°F | -4°F~140°F | 1.5 | ||
Humidity | 0~100%RH | 3.5 | ||
Sampling Rate | 2 time/sec |
Parameter | Range | Accuracy % |
---|---|---|
Air Velocity | 0.50 m/s to 27.0 m/s | 3 |
Air flow | 0.00 to 2999 m³/h | 8 |
Temperature°C | -20.0 °C to +50.0 °C | 0.8 |
Temperature°F | -4 °F to +122 °F | 1.6 |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Light Range (lx) | 0.00~40,000 lx | 3 | ||
Light Range (fc) | 0.000~4000 fc | 3 | ||
Sample Rate | 2 times/sec |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Light Range (lx) | 0.0~199900 lx | 3 | ||
Light Range (fc) | 0.0~19990 fc | 3 | ||
Sample Rate | 2 times/sec | |||
ATEST EL 724 | ||||
Light Range (lx) | 0.0 to 99.9/1999/ 19990/199900 lx |
3 | ||
Response Time | 0.5 sec |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
Light Range (lx) | 0.1 lx to 2,00,000 lx | 3 | ||
Light Range (fc) | 0.01 fc to 18,580 fc | 4 | ||
Response Time | 0.5 sec |
Parameter | Range |
---|---|
RPM functions | 60 to 1,00,000 RPM |
m/min function | 60 to 10,000 m/min |
Hz function | 1 to 10,000Hz |
ms function | 0.1 to 1000ms |
Repot function | 0.1 to 10% |
Counting function | 0 to 1,00,000events |
Parameter | Range | Accuracy % |
---|---|---|
Sound level | 30~130dB | 1.4 |
Frequency | 20Hz to 8KHz |
Parameter | Range | Accuracy % |
---|---|---|
CO2 Measurement | 30~0 to 5000 ppm | 3 |
Temperature | -10 °C to +60 °C | 0.5 |
Humidity | 5 to 95 % RH | 2 |
Parameter | Range | Accuracy % | ||
---|---|---|---|---|
CO | 0 to 1000 ppm | 5 | ||
Temperature °C | -20 to 70°C | 0.8 | ||
Temperature °F | -4 to 158°F | 1.5 | ||
Sensor | Stabilized electrochemical CO specific sensor |
Specification | Ampflex A193 450 mm |
Ampflex A193 800 mm% |
MN 93 | MN 93A |
---|---|---|---|---|
Dia(mm) | 140 | 250 | 20 | 20 |
Maximum Current |
10,000Aac | 10,000Aac | 240Aac | Dual range 5Aac & 100Aac |
Range | 100mA to 10,000Aac (measures from 10A when used onALM10) |
1A to 200Aac | 5mA to 5Aac / 100mA to 100Aac |
|
Accuracy | ±2% | ±2% | ±2% | ±0.7% |
Safety | CAT IV 600V/ CAT III1000V |
CAT IV 600V/ CAT III1000V |
CAT IV 600V/ CAT III 1000V |
CAT IV300V/ CAT III600V |
Specification | PAC 93 | C193 | J93 | E3N |
---|---|---|---|---|
Dia(mm) | 39 | 52 | 72 | 11.8 |
Maximum Current |
1000Aac/ 1300Adc |
10,00Aac | 3,500Aac/ 5000Adc |
100Aac/dc |
Range | 1A to 1,000Aac/ 1A to 1300Adc |
1A to 1,000Aac | 50A to 3,500Aac/ 50A to 5,000Adc |
10mA to 100mAac/dc |
Accuracy | ±3% | ±0.2% | ±1% | ±1% |
Safety | CAT IV 300V/ CAT III 600V |
CAT IV 600V | CAT IV300V/ CAT III600V |
CAT IV300V/ CAT III600V |
Specification | I-Flex 450 | CLD 600 |
---|---|---|
Dia(mm) | 140 | 36 |
Maximum Current |
3000 A | 600A (AC,DC) |
Range | 30 A, 300A, 3000 A | 0.1 A … 100A / … 600A |
Accuracy | ±3% | ±2% |
Safety | 1000 V CAT III, 600 V CAT IV | Cat. III 600V, Cat. II 1000V |
Introduction:
The Dranetz HDPQ® family of Power Quality, Demand and Energy instruments is the latest in a long line of industry leading products from Dranetz. The Dranetz HDPQ instruments are: Visa, Guide, Xplorer
Parameter | Range | Accuracy % |
---|---|---|
Voltage AC/DC | 0-1000Vrms, <40V 0.5%FS | ±0.1 |
Current AC/DC | Range probe dependent | ±0.5 |
Power | W,VA,VAr,Demand in W, Wh | ±0.2 |
Power Factor | (W/VA) -”true” -1 to 0 to +1 | 1 |
-1 to 0 to +1 | 1 | |
Vthd | 0-100%, for V>=10% Vnom | ±5 |
V Individual | 2-127, for V>=10% Vnom | ±5 |
I thd | 0-100%, for I>=10% Inom | ±5 |
I Individual Harm | DC, 2-63, for I>=10% Inom | ±5 |
Short Time Flicker | 10 minutes: 0.2-10,@ Pst=1 | ±5 |
Long Time Flicker | 2 hours: 0.2-10, @ Pst=1 | ±5 |
Dran-view 7 software is a Windows based software package that enables power professionals to simply and quickly
visualize and analyze power quality/energy monitoring data. Now in its 7th major revision, Dran-View 7 offers the powerful
feature set that you expect from Dran-View, but now it has a more modern appearance and a simpler user interface. Also, Dran-View 7 is a true 64 bit program that can take full adavantage of the speed and file size capabilities the latest computer/Windows Operating Systems, but remains compatible with older 32 bit computers.
Setup installation errors can be corrected even after the data has been recorded, to include the following:
Temperature Range | 20°C to 60°C |
Temperature Control Accuracy | ± 0.1°C |
Temperature Uniformity | ± 1°C |
Humidity Range | 40% RH to 95% RH |
Humidity control Accuracy | ± 2% RH |
Humidity Uniformity | ± 3% RH |
DESCRIPTION
Double walled with 80 mm PUF insulated modular panels with easy on-site assembly | System is made up of split type condenser unit in well-ventilated area to avoid throw of hot air in the room |
SS 304 Interior & Exterior either SS 304 or Powder Coated G.I. | Stand by humidity system |
Stainless Steel Trays | Complete Operations driven through PLC with data logging capacity of upto 1000 readings & email facility |
Full length Inner glass door | High speed Ethernet based communication |
Illuminated working area | All operations through a single 4″ Color Touch Screen |
U-shaped SS tubular heaters | High-quality German Make temperature humidity sensor with 4-20mA output |
Forced air circulation for uniform temperature | Safety devices: Low & High temperature cut-off settable thermostats & high humidity cut-off device |
Non Condensing steam injection type humidity system with standby heater & auto switch overs | Audio/Visual alarms for deviations |
CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser | Complete with DQ, IQ, OQ, PQ & Operations & Maintenance Manual |
Exterior &Interior is of stainless steel (SS 304) | Capacity | Internal Size | External Size | Tray Qty. | Tray Size | Approx. Weight kg | ||
---|---|---|---|---|---|---|---|---|
Cu. ft. | Liters | H x W x D (mm) | H x W x D (mm) | mm | Equip | Ship | ||
PG 430/20 to 60 /RH/A | 16 | 430 | 1200x600x600 | 1795x730x1095 | 3 | 530×560 | 250 | 325 |
PG 600/20 to 60 /RH/A | 21 | 600 | 1200x700x700 | 1795x830x1195 | 3 | 630×660 | 275 | 350 |
PG 1000/20 to 60 /RH/A | 34 | 1000 | 1500x800x800 | 2095x930x1295 | 4 | 730×760 | 325 | 425 |
PG 2000/20 to 60 /RH/A | 71 | 2000 | 1500x1600x800 | 2095x1760x1295 | 8 | 710×760 | 375 | 475 |
Rain Spray System (Meet IPX3 and IPX4, 4K test) | |||
(IPX3,4) | (IPX4K) | ||
controller | LCD Touch Screen Display And Controller | ||
Nozzle diameter | 0.4 mm | 0.8 mm | |
Nozzle distance | 50 mm | ||
Flow rate | 0.07 L/min | 0.6 L/min +/-0.5 % | |
Arm Radius in mm | 200 mm | ||
Rotating angle | +/- 270,Adjustable | ||
Rotating speed | Adjustable (60 deg per sec) | ||
Rotating table | Speed Is Adjustable (option for – Both deration rotate) | ||
Plate | Adjustable Spray For Flow and Spray Time | ||
Pressure regulator | 0- 400 KPA Adjustable | ||
Interior / exterior | SS 304 / MS with Powder Coated |
Swing pipe diameter | 0.2m, 0.4m, 0.6m, 0.8m, 1.0m
(according to the size of the measured object to select the swing pipe size) |
Pendulum tube angle | 60 degrees ,vertical ± 90 and 180 degrees |
Orifice | The removable design, pinhole 0.4 mm, specially designed nozzle, spray rain water pressure 50-150kpa |
Testing temperature | Room temperature |
Specimen rotate speed | 1-3r/min (Adjustable) |
Pressure gauge | 50-150Kpa |
Oscillating angle | IPX3: spray ±60° from vertical line to each side, total 120°
IPX4: spray ±180° from vertical line to each side, total 360° |
Oscillating speed | IPX3: 2*120° for 4s
IPX4: 2*360° for 12s |
Specification | DUST-450 | DUST-1000 |
---|---|---|
Chamber volume (Litres) | 50 | 80 |
Internal Dimensions (WXDXH) (mm) |
420mmX395mmX350mm | 450mmX400mmX450mm |
Internal Dimensions (WXDXH) (mm) |
720mmX590mmX520mm | 740mmX618mmX630mm |
Temperature Range (°C) | 5°C above ambient to +80 °C | |
Temperature accuracy | +1°C | |
Display resolution | +-1°C | |
Timing range | 1~9999min | |
Shelves (Nos) | 2 | |
Power consumption | 1100W | 1550W |
Electrical requirements | 220V, 50Hz, Single phase |
Specification | HAO-100 | HAO-150 | HAO-250 |
---|---|---|---|
Test space Dimentions (WXDXH) (mm) |
450mmx 450mm x 600mm | 500mmx 500mm x 650mm | 600mmx 600mm x 750mm |
Test space Volume (L) | 100 | 150 | 250 |
Temperature Range (°C) | above ambient +40°C to +200°C |
above ambient +40°C to +200°C |
above ambient +40°C to +200°C |
Temperature Fluctuation (°C) | +1°C | ||
Electrical Supply | 1ø/N/E 230VAC +10% 50Hz | ||
Type of controller | Option PC based software for Data Logging |
Catalouge No | CRB-20LTR |
---|---|
capacity | 16 bags |
volume | 20liters |
Temperature | 4.0°C |
Accuracy | +-0.5 °C |
Input Voltage | 230v AC |
suitable Fluids | D.M.Water |
Model | bath | control | Concentric Rings | Heating |
---|---|---|---|---|
CR6 | 30*20*10 cm | Digital | 6 holes of 75 mm with steps of 25 mm | 800w*1 |
CR12 | 40*30*10 cm | Digital | 12 holes of 75 mm with steps of 25 mm | 800w*2 |
CR24 | 60*40*10 cm | Digital | 24 holes of 75 mm with steps of 25 mm | 1500w*2 |
Chamber Operation | Both the chambers are independently operable and can be synchronized for one common operation. |
Performance | To carry out steady state as well as Cyclic Temperature tests :
A. Climatic tests B. Rain test C. IR test with black body test D. Dual test |
Temperature range | -40℃~+150℃ in both chambers with 1% accuracy |
Work Space | Work room 1- Inner size 2184 Litter – 1300 mm W x 1500 mm D x 1200 mm H
Work room 2- Inner size 2184 Litter – 1300 mm W x 1500 mm D x 1200 mm H |
External dimensions | 3175 x 2375 x 2450 (WxHxD) |
Humidity | 20 – 98 % RH / ± 3 % RH limited by minimum the Climatic range of + 25 OC to +80 OC. |
Infrared Light test setup | 9 IR lamps with Irradiation Power range : 1200 W/m² to 500 W/m² in the 1300 x 700mm target area automatically controlled with the Block sensor method |
Water Spray test setup | Nozzle – 4nos (over all flow rate 30L/M)
Water temp 5 deg to ambient Spray water pressure: 2.9 Bar (290 Kpa) |
Control system | Siemens PLC 2 Nos with one PC & software |
Construction Features | Interior SS304 sheet thickness – (1.5mm) Stainless Steel Argon arc welded |
Chiller | 2 chiller units for condenser cooling & spray water cooling are included |
Exterior | Outer MS sheet thickness 1.5 mm with powder coated |
Insulation | 125 mm thick Puf/Glass wool insulation |
Doors | 1. Front side two number door size 1100 mm W x 1000mm H with
Viewing window 300 x 400 mm 2. Left & right side each One number Door 800 mm W x 1000 mm H |
Power source inside chamber | Aplab made Power source 60V/30A : DC power source (Adjustable) |
Temperature uniformity | ≤2℃(empty load and constant state) |
Temperature deviation | ±2℃(empty load and constant state) |
Humidity Deviation | +2~-3%(>75%RH) |
±5%(≤75%RH) | |
Heating up time | Less than 90 min(20℃ → +130℃, average rate ≥2℃ /min during the whole test, empty chamber) |
Cooling down rate | Less than 90 min(20℃ → -40℃, average rate ≥ 1℃ /min during the whole test, empty chamber) |
Water cooling time | Time for spray water cooling down: +25~+5℃ , 80L water requires 60 minutes. |
Port holes | 2 Nos. 100mm both sides |
Partition door | Partition Door Dimension 1300 mm W x 800 mm H – made with FRP material |
Silicon Gasket | Double gasket, one on the chamber and one on the door. |
Hinges & Latches | Heavy duty hinges with toggle type locking arrangement. |
Mounting | Floor mounting type with wheel. |
Noise | Max 80 dB |
Model | W-ETC |
Size | 200 to 8,000 cu. ft. (5,600 to 226,500 liters) of work space Custom Sizes Available |
Temperature Range | Single Stage: -34°C to +190°C (-30°F to +375°F) Range: -45°C to +190°C (-50°F to +375°F) II Range: -50°C to +190°C (-58°F to +375°F) Cascade: -70°C to +190°C (-94°F to +375°F) |
Optional Humidity Range | 10% to 95% RH |
Product Model | IP-X9K-500C | IP-X9K-1000C | IP-X9K-1250C |
Volume | 500 Liters | 1000 Liters | 1250 Liters |
Test Room (WxHxD) mm | 800*800*800 | 1000*1000*1000 | 1000*1250*1000 |
External Dimension (WxHxD) mm | 1300*1150*1800 | 1500*1950*1300 | 1500*1550*1950 |
Sample Test Distance | 100mm~150mm | 100mm~150mm | 200mm~400mm |
Test Sample Load Weight | 10KG~ 15 KG | 15KG~ 20 KG | 20KG~ 40 KG |
Water Pressure | 8000Kpa~10000Kpa | 8000Kpa ~10000Kpa | 80 Bar~100 Bar |
Water Spray Angle | 0°, 30°, 60°, 90° | ||
Nozzle Design | Custom SS 304 four fan nozzles made of stainless steel, located at 0°, 30°, 60°, 90° of the test platform level | ||
The distance between the nozzle and the test object is 100~150mm, and the distance between the nozzle and the test plate can be adjusted. | |||
The maximum movement distance of the nozzle is 300mm, and the Angle error is every 50mm | |||
Injection Design | Each IPX9K nozzle is equipped with high pressure and high temperature actuating solenoid valve, and the actuating time of each Angle is 10 seconds (it can be set and changed for 0-5min) | ||
The IPX9K nozzle can set the injection time and stop time, and spray in turn (0-1000 cycles can be set) | |||
Spray Nozzle | Four Units, 30 seconds each position | ||
Spray Range | 30° ± 5°(Single hole)|Space 100-150mm | ||
Water Spray Temperature | Room temp +10°C ~ 88°C (Adjustable) | ||
Hot water storage tank temperature can reach 88 ℃ (hot water injection test, high pressure hot spray) | |||
Sight Window | Equipped with 10 mm reinforced glass and explosion-proof transparent protective film, the internal lighting adopts isolated lighting | ||
Water Flow Rate | 14 L-16 L/min | ||
Testing Sample Shelf | SS 304, Speed: 5 ±1 r.p.m | ||
Shelf Height | 200-400 mm, Rotate 360 degrees horizontally | ||
Test Platform Diameters | 550 mm, 600 mm (Options) | ||
Ambient Temperature | 5 ℃ ~ + 32 ℃|Ambient humidity:≤85% | ||
Power Requirements | AC 415/N/E( ±10%)V/50HZ Three-phase Five-wire system |
TECHNICAL SPECIFICATIONS
Temperature and Humidity Test Chamber Specification
Technical Description of the Infrared System
Irradiation Parameter
Irradiation Spectrum:
VIS: 6 % (380 – 780 nm)
IR-A: 46 % (780 – 1.400 nm)
IR-B: 44 % (1.400 – 3.000 nm)
IR-C: 4 % (3.000 – 10.000 nm)
Irradiation Distance: approx. 600 mm from bottom lamps to target area
Irradiation Power: 1200 W/m² to 100 W/m² in the target area
Integrate the dimmer pack into your chamber controlDual Climatic test Chamber Combined with Rain and IR lamp Test
Parameter | 3-Phase | 1-Phase / 2-Phase |
---|---|---|
Rating | 3kVA to 3500kVA | 1kVA to 20kVA |
Reference Standard | IS 11171 : 1985 (Reaffirmated 2006) | |
Type of Transformer | Floor mounted, natural air-cooled /oil-cooled (depending on rating) | Dry type, floor mounted, natural air-cooled |
Configuration | Delta / star 1:1 (or as per user specification) | 1:1 (or as per user specification) |
Default Vector Group | Dyn11 | |
Type of lamination | CRNO / CRGO | |
Load Regulation | Better than 3% | |
Class of insulation | Class H | |
Efficiency | 3 – 12 kVA (>95%)> 15 kVA (>97%)At rated input voltage and at 100% rated current of loads that are linear | |
Insulation strength | Withstands 2.5 kV for 1 minute (between windings & between windings and body) | |
DC galvanic isolation | >1000 Mega Ohms – for UIT >100 Mega Ohms – for GIT | |
Common Mode noise rejection (for UIT only) | Up to 10kHz > 100 dB 10 kHz to 50 kHz > 60 dB 50 kHz to 1 MHZ > 40dB | |
Short Circuit Protection Indications | HRC fuse at input provided as a standard upto 200kVA | |
Indications | LED Lamps for Output Presence | |
Housing | Sheet metal housing provided with Input / Output terminations | |
Standards | IS 2026 Standards |
SAVE ENERGY | Track Daily Energy Consumption | Set Energy Targets |
Monitor Deviations | Monitor PF and load variations | |
Monitor Night time Wastages | Get Alarms for low PF | |
SAVE TIME | Receive daily Energy reports on your Mobile APP | Save engineer’s time for data collection |
IMPROVE PERFORMANCE | Monitor Stabiliser Performance | Monitor Unbalances |
Get Alarms for Stabiliser TRIP | Get Alarms for Low/high voltage and overload |
Feature | 3 Phase Unbalanced Air cooled(AU/AR Models) | 3 Phase Unbalanced Oil cooled(OU/OR Models) |
---|---|---|
Rating (kVA) | 3-500 | 3-4000 (OU)/ 15-500 (OR) |
Type of cooling | Air | Oil |
Input voltage range (V L-L)* | 310-480 / 340-480 / 360-460 | |
Output voltage (V L-L)* | 415 (380V/400V – optional) | |
Output Voltage Regulation | 1% of nominal output voltage | |
Input frequency range | 47Hz — 53Hz | |
Efficiency | >97% | |
Effect of Load Power Factor | Nil | |
Waveform Distortion | Nil | |
Type of Servo Control | Micro Controller based True RMS sensing and correction | |
Servo Motor Drive | Triac based drive for AC Step Synchronous motor | |
Under/ Over Voltage cutoff * | Electronic cutoff circuit with graded time delay, set @ +5% /-10% of nominal output voltage | |
Overload cutoff | CT based Electronic cutoff circuit with graded time delay set @ 110% of rated full load current | |
Short circuit protection | MCB / MCCB provided up to 100 kVA HRC fuse provided for 125-200 kVA |
|
Single phasing prevention | Provided in AU/OU models only; Not provided in the AR/OR models | |
Phase Reversal Trip | Provided in AU/OU models only; Not provided in the AR/OR models | |
Stabiliser bypass | Provided up to 50 kVA 3-phase; Optional > 50 kVA | |
Transient Suppression | Spike Suppression through MOV is provided (Surge Arrestor is optional) | |
Emergency Off Switch | Provided in AU/OU models only; Not provided in the AR/OR models | |
Frequency cut off protection | Optional | |
Input High Voltage Trip | Optional | |
Resetting mode | Manual / Auto option provided with programmable time delay | |
Display Type | 2 Line LCD Panel | |
Parameters displayed | Input & Output Voltages (Line & Phase), Output Currents & Frequency | |
Input / Output Terminations | Bolted Terminals up to 100kVA, Busbar 125kVA and above | |
Standards | IS 9815 (Part – 1) : 1994 |
MODEL | SX-030 | SX-040 | SX-060 | SX-080 | SX-100 | SX-120 | |
---|---|---|---|---|---|---|---|
Capacity | 30kVA 27kW | 40kVA 36kW | 60kVA 54kW | 80kVA 72kW | 100kVA 90kW | 120kVA 108kW | |
INPUT | |||||||
Rated Voltage | 400Vac | ||||||
Voltage Range | ± 25% | ||||||
Rated Frequency | 50 / 60 Hz | ||||||
Frequency Range | 50 / 60 Hz ± 5 Hz | ||||||
Bypass Voltage Range | ± 20% (settable) | ||||||
Delayed Start of Rectifier | 1 ~ 300 s (settable via display panel) | ||||||
ECO Voltage Range | ± 10% (settable) | ||||||
OUTPUT | |||||||
Voltage | 380V / 400V / 415Vac | ||||||
Voltage Regulation | ± 1% | ||||||
Frequency | Synchronized with utility in mains mode; 50 / 60 H± 0.1% in battery mode | ||||||
Waveform | Sinusoidal | ||||||
Power Factor | 0.9 | ||||||
Crest Factor | 3:1 | ||||||
Total Harmonic Distortion (THDV) | ≤2% (linear load); ≤5% (non-linear load) | ||||||
Transfer Time | AC mode to battery mode: 0ms | ||||||
Inverter mode to bypass mode: 0ms | |||||||
Inverter mode to ECO mode: 5 ~ 10ms | |||||||
Overload | 105%: long time running, 105% ~ 110% for lh, | ||||||
110% ~ 125% for 10 min, 125% ~ 150% for 1 min, 150% ~ 200% for 200ms, >200% for 100ms | |||||||
BATTERIES | |||||||
DC Voltage | 12V x configured battery number (settable via display panel) | ||||||
Number of Battery | 28~32 pcs (settable) | ||||||
Charging Current | 10A default / settable | ||||||
Charging | Three-stage charging, auto switch floating / equalizing charge | ||||||
Battery State Display | Display battery backup time, battery remaining capacity | ||||||
Battery Self-test | Settable periodic self-test; manually configurable test time and voltage | ||||||
SYSTEM | |||||||
Efficiency | Online mode:upto 93%; ECO mode:98%≥ | ||||||
Parallel Numbers | max6 | ||||||
Protections | Short-Circuit, Overload, Over-voltage, Under-voltage, Low Battery, Over-temperature, Fan fault | ||||||
Communications | RS232 / RS485 / Dry Contacts (standard), SNMP (optional) | ||||||
IP Rating | IP20 | ||||||
EMI | EN62040-2 | ||||||
EMS | IEC61000-4-2(ESD), IEC61000-4-3(RS), IEC61000-4-4(EFT), IEC61000-4-5(surge) | ||||||
OTHERS | SX-030 | SX-040 | SX-060 | SX-080 | SX-100 | SX-120 | |
Humidity | 0 ~ 95% RH @ 0 ~ 40°C (non-condensing) | ||||||
Noise Level | 55dB | 60dB | 85dB | ||||
Dimensions (W x D x H) (mm) | 400 x 800 x 1100 | 600x700x1500 | 700 x 800 x 1700 | ||||
Packaged Dimensions (W x D x H) (mm) | 490 x 920 x 1250 | 700x800x1850 | 800 x 900 x 1850 | ||||
Net /Gross Weight (kg) | 210/252 | 260/302 | 460/480 | 590/620 | 630/660 | 690/720 |
MODEL | HX-80 | HX-100 | HX-120 | HX-160 | HX-200 | HX-250 | HX-300 | ||
---|---|---|---|---|---|---|---|---|---|
Capacity | 80kVA | 100kVA | 120kVA | 160kVA | 200kVA | 250kVA | 300kVA | ||
72kW | 90kW | 108kW | 144kW | 180kW | 225kW | 270kW | |||
INPUT | |||||||||
Rated Voltage | 400Vac | ||||||||
Voltage Range | 346V to 456V (full load) 304V to 346V (power derating 10%) | ||||||||
Rated Frequency | 50 / 60 Hz | ||||||||
Frequency Range | 50 / 60 Hz ± 5Hz | ||||||||
Power Factor | ≥0.99 | ||||||||
Total Harmonic Distortion (THDI) | ≤3% | ||||||||
Input Current-limiting | 1.1 times of rated current (0.1 ~ 1.1 settable) | ||||||||
Rectifier delay start | 10 s (1 ~ 300 settable) | ||||||||
Bypass Voltage Range | ± 20% (settable) | ||||||||
OUTPUT | |||||||||
Rated Voltage | 380V / 400V / 415 Vac | ||||||||
Voltage Regulation | ± 1% | ||||||||
Frequency | Synchronized with utility in mains mode; 50 / 60 Hz± 0.1% in battery | ||||||||
Waveform | Sinusoidal | ||||||||
Crest Factor | 3 : 1 | ||||||||
Total Harmonic Distortion (THDV) | ≤ 2% (linear load); ≥ 5% (non-linear load) | ||||||||
Transfer Time | 0 ms | ||||||||
Inverter Overload Capability | 105% ~ 110% for 60 min; | ||||||||
110% ~ 125% for 10 min | |||||||||
BATTERIES | |||||||||
DC Voltage | 600 Vdc (supports 576 Vdc / 588 Vdc / 612 Vdc / 624 Vdc) | ||||||||
Number of Battery | 50 pcs (supports 48 / 49 / 51 / 52 pcs) | ||||||||
Charging Current | Charging rate (settable) x battery capacity (settable) x number of battery group (settable) | ||||||||
Battery State Display | Battery remaining capacity and backup time | ||||||||
Battery Self-test | Settable periodic self-test; manually configurable test time and voltage | ||||||||
SYSTEM | |||||||||
Efficiency Max. Parallel Numbers | Lien mode≥ 93%; ECO mode≥ 98% | Lien mode≥ 94%; ECO mode≥ 98% | |||||||
6 | |||||||||
Protections | Short-circuit, Overload, Over Temperature, Over Voltage, Under Voltage, Battery Low Voltage and Fan Failure | ||||||||
Communications | RS232 / RS485 / dry contacts (standard); SNMP (optional) | ||||||||
IP Rating | IP20 | ||||||||
Display | 5.7 inches LCD touch screen | ||||||||
OTHERS | HX-80 | HX-100 | HX-120 | HX-160 | HX-200 | HX-250 | HX-300 | ||
Operating Temperature | 0°C to 40°C | ||||||||
Storage Temperature | – 25°C to 55°C (without battery) | ||||||||
Humidity | 5% to 95% (non-condensing) | ||||||||
Noise Level at 1 m | < 65 dB | ||||||||
Dimensions (W x D x H) (mm) | 800 x 800x 1800 | 800 x 860 x 1700 | 1210 x 860 x 1950 | ||||||
Packaged Dimensions (W x D x H) (mm) | 900 x 900 x 2050 | 900 x 1000 x 1950 | 1300 x 1000 x 2200 | ||||||
Net / Gross Weight (kg) | 580 / 630 | 630 / 680 | 680 / 730 | 790 / 810 | 1135 /1200 | 1275 /1340 | 1355 /1420 |
Particulars | UDF 90 | UDF 185 | UDF 360 |
---|---|---|---|
Internal Volume(Liters) | 90 | 185 | 360 |
No. of trays | 2 | 3 | 6 |
No. of Internal Door | 1 | 2 | 4 |
Internal Dimension W x D x H (mm) | 400 x 400 x 580 | 510 x 510 x 730 | 700 x 510 x 1000 |
External Dimension W x D x H (mm) |
711 x 877 x 1405 | 820 x 987 x 1560 | 1010 x 987 x 1830 |
Operating Temperature Range | -45°C to -86°C | ||
Insulation (CFC free polyurethane foam) | Body : 150 mm sides, 300 mm Back, Door : 110 mm | ||
Temperature Control | Microprocessor PID controller with PT-100 Class A sensor | ||
Optional HMI Display | 7″ touch Screen | ||
Power Failure Alarm | Audio Visual Alarm | ||
Door Open Alarm | Audio Visual Alarm in case door open for over one minute | ||
Inner Body Material | S.S. 304 (AISI Grade, Non Corrosive, Non Magnetic) | ||
Outer Body Material | Powder Coated CRCA Steel | ||
Noise Level | Less Than 65 db(A) | ||
Electrical | 220-240 volts, 50 Hz, SINGLE PHASE | ||
Specification | SESS/PI-0 | SESS/PI-2 | SESS/PI-2 |
---|---|---|---|
Temperature Range (°C) | 15-35°C | ||
Temperature accuracy | ±0.1 | ||
Timer (min) | 0-999 | ||
Variation (%) | ±0.5 | ||
Power (KW) | 0.5 | 0.8 | 1.35 |
Interior Dimensions(HxWxD) (mm) | 530X390X390 | 1050X670X600 | 390X480X300 |
Overall (HxWxD) (mm) | 820X590X390 | 1500X670X600 | 680X480X300 |
Tray size (HxWxD) | 950X1090X390 | 1750X1170X600 | 390X480X300 |
Net Weight (KG) | 110 | 180 | 320 |
Catalogue No. | PTB-20 | R-PTB-20 |
Capacity | 16 bags | 16 bags |
Volume | 20 liters | 20 liters |
Temperature | 37 ºC | 4.0 ºC |
Accuracy | ± 0.2 ºC | ± 0.2 ºC |
Input Voltage | 230 V AC | 230 V AC |
Suitable Fluids | D.M water | D.M water |
Specification | DUST-450 | DUST-1000 |
---|---|---|
Chamber volume (Litres) | 50 | 80 |
Internal Dimensions (WXDXH) (mm) |
420mmX395mmX350mm | 450mmX400mmX450mm |
Internal Dimensions (WXDXH) (mm) |
720mmX590mmX520mm | 740mmX618mmX630mm |
Temperature Range (°C) | 5°C above ambient to +80 °C | |
Temperature accuracy | +1°C | |
Display resolution | +-1°C | |
Timing range | 1~9999min | |
Shelves (Nos) | 2 | |
Power consumption | 1100W | 1550W |
Electrical requirements | 220V, 50Hz, Single phase |
Model | Internal | Dimensions in cms | Max No. of Trays | |||||
---|---|---|---|---|---|---|---|---|
(S)OR(G) | Cu.Ft/Ltrs. | Internal | External | |||||
W | D | H | W | D | H | |||
BOD 90 S/G | 3/90 | 45 | 40 | 50 | 60 | 82 | 104 | 3 |
BOD 200/G | 8/200 | 60 | 63 | 60 | 75 | 106.5 | 117 | 4 |
BOD 325/G | 12/325 | 60 | 60 | 90 | 75 | 106.5 | 147 | 6 |
BOD 400 S/G | 16/400 | 60 | 63 | 106 | 75 | 106.5 | 163 | 7 |
BOD 600 S/G | 22/600 | 80 | 80 | 95 | 95 | 126.5 | 154 | 6 |
BOD 800 S/G | 28/800 | 80 | 80 | 125 | 95 | 126.5 | 187 | 9 |
BOD 1000 S/G | 32/1000 | 80 | 8 | 157 | 95 | 126.5 | 219 | 11 |
Model No | BBR 60 ltr | BBR 150 ltr | BBR 300 ltr |
---|---|---|---|
capacity(no of bags) | 60 | 160 | 300 |
Trays | 2 | 4 | 4 |
Inner Dimensions(mm) | 400(w)*430(d)*810(h) | 555(w)*430(d)*1310(h) | 700(w)*520(d)*1310(h) |
voltage | 230VAC/50HZ | 230VAC/50HZ | 230VAC/50HZ |
Name Of The Requirement | Micro Controller Based Blood Bank Refigirator |
---|---|
Control System | Micro controller based temperature indicator cum controller with digitsl display and PT 100 sensor |
Alarm | Audio visual alarm if the temperature deviates from the present temperature |
Refrigeration System | Hermitically sealed Cfc free emerson/damfose compressor with R 134 a refrigerant |
Air Curculation | Motor and blower arrangement to have uniformity temoerature under loaded temperature |
Insulation | 100 MM thick CFC free PUF insulation |
Lighting | Interior illumination for Working area |
Observation Code | Inside see through unbreakable acrylic door |
Trays | specially degigned for stainless steel baskets |
others | castrol wheels MCB,Heavy duty latch with lock and key |
power | works on 230 v AC single phase 50HZ |
Temperature Recorder | 7 days circular chat G-tek |
safety features | 180 sec compressor ‘on’ delay timer to safe guard the compressor |
Technical Data | ||
Model No. | DFV – 245 | DFV – 340 |
---|---|---|
Capacity (Liters) | 245 | 340 |
Temperature Range °C | -16 ° C -24 ° C | |
Door | 1 | 1 |
Baskets / Shelves | 6 | 7 |
External Dimensions (mm) | ||
Width | 533 | 610 |
Depth | 610 | 635 |
Height | 1448 | 1854 |
Technical Data | ||
Model No. | UTC – 265 | UTC – 400 |
---|---|---|
No. of Doors | 2 | 3 |
Capacity (Litters) | 265 | 400 |
Temperature Range °C | -10 to -20 | -10 to -20 |
Fully Automatic Controller with Temp. Display | LED | LED |
Ext. Dimension (W x D x H) in mm | 1360 x 700 x 860 | 1795 x 700 x 860 |
Int. Dimension (W x D x H)in mm | 795 x 580 x 560 | 1230 x 580 x 560 |
Specification | ETC-275 | ETC-480 | ETC-800 | ETC-1200 |
---|---|---|---|---|
Effective capacity L | 275 | 480 | 800 | 1200 |
Temperature range@20°C | +5~+65 | +5~+65 | +5~+65 | +5~+65 |
Temperature stability±°C | 0.1~0.2 | 0.1~0.2 | 0.1~0.2 | 0.1~0.2 |
Temperature deviation °C | 1.0 | 1.0 | 1.0 | 1.0 |
Humidity range(std)opt) | 40~95%RH | 40~95%RH | 40~95%RH | 40~95%RH |
Humidity range(opt) %RH | 20~95 | 20~95 | 20~95 | 20~95 |
Humidity stability ±%RH | 1-2 | 1-2 | 1-2 | 1-2 |
Humidity deviation %RH | 3-5 | 3-5 | 3-5 | 3-5 |
Heater wattage W | 450 | 450 | 950 | 950 |
Cooling capacity@20°C W | 250 | 350 | 500 | 800 |
Interior size(WDH) mm | 535×480×950 | 635×560×1350 | 935×640×1350 | 1235×720×1350 |
Overall size(WDH)mm | 640×660×1600 | 740×740×1972 | 1040×820×1972 | 1340×900×1972 |
Air movement | Horizontal | Horizontal | Horizontal | Horizontal |
Shelves (standard/maximum) | 2/5 | 3/7 | 3/7 | 3/7 |
Specification | Vibro-ETC 400 Vibro-ETC 400C |
Vibro-ETC 600 Vibro-ETC 600C |
Vibro-ETC 1200 Vibro-ETC 1200C |
Vibro-ETC 2200 Vibro-ETC 2200C |
---|---|---|---|---|
Useful area capacity (I) | 400 | 600 | 1200 | 2200 |
Internal dimensions approx. (mm) WIDTH x DEPTH x HEIGHT |
700 x 700 x 800 | 850 x 750 x 950 | 1000 x 1150 x 1080 | 1350 x 1350 x 1200 |
Distance between the bottom of the test space and the floor (mm) |
650….1400 | 650….1400 | 700….1400 | 700….1400 |
Temperature Range (°C) TC _ _ _ _ ETC _ _ _ _ C fluctuation |
-40 to 180°C -70 to 180°C ±1…±1.5 |
-40 to 180°C -70 to 180°C ±1…±1.5 |
-40 to 180°C -70 to 180°C ±1…±1.5 |
-40 to 180°C -70 to 180°C ±1…±1.5 |
Temp. changing rate Heating | 5 | 5 | 5 | 5 |
Temp. changing rate Cooling | 5 | 5 | 5 | 5 |
Humidity range (%) (t= 25/+80°C) fluctuation |
10 to 98% ±3…±5 |
10 to 98% ±3…±5 |
10 to 98% ±3…±5 |
10 to 98% ±3…±5 |
Temp. range for climatic test corrector |
20 to 85°C | 20 to 85°C | 20 to 85°C | 20 to 85°C |
Supply voltage (Vac) | 410V ±10%/50Hz/3 + N + G |
Specification | TS 25L-B2 | TS 64L-B2 | TS 120L-B2 |
---|---|---|---|
Test Basket Zone (W x D x H) in mm | 250 x 250 x 400 | 400 x 400 x 450 | 500 x 500 x 400 |
Test Space Dimension (W XD X H) in mm | 400 x 400 x 450 | 550 x 550 x 450 | 700 x 700 x 450 |
External Dimension (W x D x H) in mm | 900 x 1860 x 2450 | 1200 x 2150 x 2450 | 1350 x 2300 x 2450 |
Hot Zone (°C) | 50 to 200 | 50 to 200 | 50 to 200 |
Cold Zone (°C) | -70 to 40 | -70 to 40 | -70 to 40 |
Basket Transition Time (Sec) | < 10 | < 10 | < 10 |
Recovery Time (Min) | < 5….15 | < 5….15 | < 5….15 |
Basket Movement | Vertical | Vertical | Vertical |
Type of Controller | Watlow / Siemens PLC/ HMI – SESS Climatic |
Watlow / Siemens PLC/ HMI – SESS Climatic |
Watlow / Siemens PLC/ HMI – SESS Climatic |
Model Number | Interior Dimensions (W x D x H) |
Interior Volume | Temperature Range | Humidity Control | Notes |
---|---|---|---|---|---|
TENSIL 9.7 /-35/RH | 12~15″ x 16~28″ x 15~40″ | 1.7 to 9.7 cu. ft. | -35 to 150°C | Yes | These chambers are customized to fit your testing equipment |
TENSIL 9.7 /-35/XX | 12~15″ x 16~28″ x 15~40″ | 1.7 to 9.7 cu. ft. | -35 to 150°C | No | These chambers are customized to fit your testing equipment |
TENSIL 9.7 /-60/RH | 12~15″ x 16~28″ x 15~40″ | 1.7 to 9.7 cu. ft. | -60 to 150°C | Yes | These chambers are customized to fit your testing equipment |
TENSIL 9.7 /-60/XX | 12~15″ x 16~28″ x 15~40″ | 1.7 to 9.7 cu. ft. | -60 to 150°C | No | These chambers are customized to fit your testing equipment |
Parameters:
Model | Temp. Range ( °C) | Temp. Accuracy (°C) | Tank Capacity (L) | Flow Rate (L/min) | Pressure (bar) | Cooling/heating power (W) | Tank Depth (mm) | Tank opening size (W*D mm) | Dimensions (W*D*H mm) | Weight (kg) |
RB201 | +5 ~ +95 | ±1 | 12 |
5~10 |
150 | 150×300 | 365×340×340 | 17 | ||
RB101 | -15 ~ +95 | ±1 | 6 | 5~10 | 0.25 | 200 | 150 | 145×130 | 420×405×400 | 25 |
RB105 | -10 ~ 95°C | ±1 | 5 | 5~10 | 0.25 | 200 | 150 | 145×150 | 215×405×550 | 26 |
RB205 | -20 ~ 95°C | ±0.5 | 5 | 5~10 | 0.25 | 200 | 150 | 140×145 | 210×405×560 | 30 |
RB305 | -30 ~ 95°C | ±0.5 | 5 | 5~10 | 0.25 | 200 | 150 | 140×145 | 215×405×560 | 33 |
RB405 | -40 ~ 95°C | ±0.2 | 5 | 5~10 | 0.25 | 200 | 150 | 140×145 | 215×405×560 | 33 |
RB2012 | -20 ~ 95°C | ±0.2 | 12 | 5~10 | 0.25 | 550 | 200 | 170×170 | 280×480×725 | 42 |
RB4012 | -40 ~ 95°C | ±0.1 | 12 | 5~10 | 0.25 | 550 | 200 | 170×170 | 280×480×725 | 45 |
RB012 | +5 ~ 99 °C | ±0.05 | 12 | 5~10 | 0.25 bar | 800 | 150 | 150×300 | 365×340×340 | 17 |
RB025 | +5 ~ 99 °C | ±0.05 | 25 | 5~10 | 0.25 bar | 1500 | 200 | 300×300 | 560×350×400 | 22 |
Specification | DUST-450 | DUST-1000 |
---|---|---|
Work Space Volume (L) (MM) | 450 | 1000 |
Test space Dimensions (WXDXH) (mm) |
750mmX750mmX750mm | 1000mmX1000mmX1000mm |
Temperature Range (°C) | 5°C above ambient to +80 °C | |
Temperature Fluctuation | ±1°C | |
Electrical Supply | 3ø/N/E 415VAC +10% 50Hz | |
Type of controller | PLC based control system |
Specification | ETC 1000 / -40 to 150 °c |
---|---|
Power of single channel | 50W/CH |
Quantity of load channels | 110CH |
Scope of load voltage | 2-100V |
Scope of load current | 0.2-5A/CH |
Load precision | ±(1%+0.1%FS) |
Qty of Layer | Six – Layer |
Height (mm) | 1300 |
Width (mm) | 1300 |
Load Model | Energy Saving |
Load mode | Constant voltage load mode + constant current load mode, CC+CV Mode |
Control system | Temperature / Humidity control type of PLC with PC software |
Temperature range | Temperature -40°C to 150°C |
Humidity Range | 10 to 98% |
Charger power socket | Universal type Power socket |
Structure material of trolley | Outer MS with Powder coated / Inner SS304 |
Mode of main control | Monitoring software for burn-in of computer-monitoring type power |
Input mode of UUT | Multi-purpose socket/speaker wire clip/custom design |
Interface mode of UUT | Connecting fixture boards (with various specifications) for first choice/custom design |
External dimension (L*W*H) | 1540 x 1668 x 1940 |
Chamber Body Material |
Model | Internal size (MM) | Pow | Voltage | Optional Refrigeration System |
---|---|---|---|---|---|
W D H H* KW | V/HZ** | ||||
FRP | SST 200 | 600 500 750 3.5 | 3.5 | 3.5 230/50/1+G | |
FRP | SST 600 | 900 640 810 1100 | 4.5 | 230/50/1+G | Yes |
FRP | SST 1200 | 1700 640 810 1100 | 5.5 | 230/50/1+G | Yes |
Inner FRP / Outer SS316 | SST 2300 | 2000 1000 1000 1300 | 7.5 | 415/50/3/N+G | Yes |
Chamber Model | Unit | TC/ETC 50 C | TC/ETC 100 C | TC/ETC 250 C | TC/ETC 550 C | TC/ETC 1000 C |
---|---|---|---|---|---|---|
Useful Internal capacity available |
Litres | 50 | 100 | 250 | 550 | 1000 |
Internal Dimension Approx in mm |
Width x Depth x Height |
400 x 300 x 500 | 500 x 400 x 600 | 600 x 600 x 750 | 850 x 7730 x 900 | 1000 x 1000 x 1000 |
Temperature range °C IEC 60068-3-5 and IEC 60068-3-6 |
TC ### | -35 to 180 °C | -35 to 180 °C | -35 to 180 °C | -35 to 180 °C | -35 to 180 °C |
ETC ### C | -70 to 180 °C | -70 to 180 °C | -70 to 180 °C | -70 to 180 °C | -70 to 180 °C | |
Control Accuracy (±°C) | (±°C) | 0.1°C | 0.1°C | 0.1°C | 0.1°C | 0.1°C |
Cooling Ramp Rate Average (Empty chamber) |
°C/min | 3°C | 3°C | 3°C | 3°C | 3°C |
Heating Ramp Rate Average (Empty chamber) |
°C/min | 3°C | 3°C | 3°C | 3°C | 3°C |
Humidty range % | % | 20/95 % | 20/95 % | 20/95 % | 20/95 % | 20/95 % |
R.H. Fluctuation | +/- % | +/- 3 % | +/- 3 % | +/- 3 % | +/- 3 % | +/- 3 % |
Supply | 230V +6/-10% / 50Hz / 1+G |
415V +6/-10% / 50Hz / 1+G |
415V +6/-10% / 50Hz / 1+G |
415V +6/-10% / 50Hz / 1+G |
415V +6/-10% / 50Hz / 1+G |
|
Refrigerating gas | R404A/R23 | R404A/R23 | R404A/R23 | R404A/R23 | R404A/R23 | |
Max. noise level with air condenser |
78d8 (A) | 78d8 (A) | 78d8 (A) | 78d8 (A) | 78d8 (A) | |
Compressor | Hermetic | Semi Hermetic | Semi Hermetic | Semi Hermetic | Semi Hermetic | |
Control system based on customer request | Non Profile / Profile controller / PLC with HMI |
Non Profile / Profile controller / PLC with HMI |
Non Profile / Profile controller / PLC with HMI |
Non Profile / Profile controller / PLC with HMI |
Non Profile / Profile controller / PLC with HMI |
|
Front Glass window | 200mm x 300mm | 200mm x 300mm | 300mm x 500mm | 300mm x 500mm | 300mm x 600mm | |
Condenser | Air cooled /Water cooled |
Air cooled /Water cooled |
Air cooled /Water cooled |
Air cooled /Water cooled |
Air cooled /Water cooled |
MODEL | SX-030 | SX-040 | SX-060 | SX-080 | SX-100 | SX-120 | |
---|---|---|---|---|---|---|---|
Capacity | 30kVA 27kW |
40kVA 36kW |
60kVA 54kW |
80kVA 72kW |
100kVA 90kW |
120kVA 108kW |
|
INPUT | |||||||
Rated Voltage | 400Vac | ||||||
Voltage Range | ± 25% | ||||||
Rated Frequency | 50 / 60 Hz | ||||||
Frequency Range | 50 / 60 Hz± 5 Hz | ||||||
Bypass Voltage Range | ± 20% (settable) | ||||||
Delayed Start of Rectifier | 1 — 300 s (settable via display panel) | ||||||
ECO Voltage Range | ± 10% (settable) | ||||||
OUTPUT | |||||||
Voltage | 380V / 400V / 415Vac | ||||||
Voltage Regulation | ± 1% | ||||||
Frequency | Synchronized with utility in mains mode; 50 / 60 H± 0.1% in battery mode | ||||||
Waveform | Sinusoidal | ||||||
Power Factor | 0.9 | ||||||
Crest Factor | 3:1 | ||||||
Total Harmonic Distortion (THDV) | <_2% (linear load); <_5% (non-linear load) | ||||||
Transfer Time | AC mode to battery mode: Oms | ||||||
Inverter mode to bypass mode: Oms | |||||||
Inverter mode to ECO mode: 5 — 10ms | |||||||
Overload | 105%: long time running, 105%— 110% for lh, | ||||||
110% — 125% for 10 min, 125% — 150% for 1 min, 150% — 200% for 200ms, >200% for 100ms | |||||||
BATTERIES | |||||||
DC Voltage | 12V x configured battery number (settable via display panel) | ||||||
Number of Battery | 28 ~ 32 pcs (settable) | ||||||
Charging Current | 10A default / settable | ||||||
Charging | Three-stage charging, auto switch floating / equalizing charge | ||||||
Battery State Display | Display battery backup time, battery remaining capacity | ||||||
Battery Self-test | Settable periodic self-test; manually configurable test time and voltage | ||||||
SYSTEM | |||||||
Efficiency | Online mode:upto 93%; ECO mode:98% | ||||||
Parallel Numbers | Max 6 | ||||||
Protections | Short-Circuit, Overload, Over-voltage, Under-voltage, Low Battery, Over-temperature, Fan fault | ||||||
Communications | RS232 / RS485 / Dry Contacts (standard), SNMP (optional) | ||||||
IP Rating | IP20 | ||||||
EMI | EN62040-2 | ||||||
EMS | IEC61000-4-2(ESD), IEC61000-4-3(RS), IEC61000-4-4(EFT), IEC61000-4-5(surge) | ||||||
OTHERS | SX-030 | SX-040 | SX-060 | SX-080 | SX-100 | SX-120 | |
Humidity | 0 ~ 95% RH @ 0 ~ 40°C (non-condensing) | ||||||
Noise Level | 55dB | 60dB | 85dB | ||||
Dimensions (W x D x H) (mm) | 400 x 800 x 1100 | 600x700x1500 | 700 x 800 x 1700 | ||||
Packaged Dimensions (W x D x H) (mm) | 490 x 920 x 1250 | 700x800x1850 | 800 x 900 x 1850 | ||||
Net / Gross Weight (kg) | 210/252 | 260/302 | 460/480 | 590/620 | 630/660 | 690/720 |
Reviews
There are no reviews yet.