Rain Spray Test Chamber is used to test anti-rain and waterproof performance for products, the products such as steam locomotive lamps, wiper performance, waterproof bands, motorcycle instruments, defense industry, navigation systems, missiles, radar cone top, aerospace industry.
Conform to JS9000, JSS55555, JIS D 0203, S 12063, I EC 60529 (IP) , DIN 40050 IP 1 TO 9k & I SO 120653 I P 1 TO 9k
Rain spray nozzles as per IS9000 I JSS 55555. Total 8 nozzles, four nozzles at the top four corners inclined at 45 degree and 4 nozzles in the center of each four sides . Pressure Gauges for each nozzle. Rotameter to monitor rate, Rotating Table.
Oscillating pipe formed in to a semi-circle with nozzles as per IP. Rotating Table with T slots.
Rotating nozzle a nd Rotating table as per JIS D 0203 Drip Test, Jet Test & Immersion Test as per IEC 60529(IP) IP 4K/6K/9K also available on request
Temperature Range | 20°C to 60°C |
Temperature Control Accuracy | ± 0.1°C |
Temperature Uniformity | ± 1°C |
Humidity Range | 40% RH to 95% RH |
Humidity control Accuracy | ± 2% RH |
Humidity Uniformity | ± 3% RH |
DESCRIPTION
Double walled with 80 mm PUF insulated modular panels with easy on-site assembly | System is made up of split type condenser unit in well-ventilated area to avoid throw of hot air in the room |
SS 304 Interior & Exterior either SS 304 or Powder Coated G.I. | Stand by humidity system |
Stainless Steel Trays | Complete Operations driven through PLC with data logging capacity of upto 1000 readings & email facility |
Full length Inner glass door | High speed Ethernet based communication |
Illuminated working area | All operations through a single 4″ Color Touch Screen |
U-shaped SS tubular heaters | High-quality German Make temperature humidity sensor with 4-20mA output |
Forced air circulation for uniform temperature | Safety devices: Low & High temperature cut-off settable thermostats & high humidity cut-off device |
Non Condensing steam injection type humidity system with standby heater & auto switch overs | Audio/Visual alarms for deviations |
CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser | Complete with DQ, IQ, OQ, PQ & Operations & Maintenance Manual |
Exterior &Interior is of stainless steel (SS 304) | Capacity | Internal Size | External Size | Tray Qty. | Tray Size | Approx. Weight kg | ||
---|---|---|---|---|---|---|---|---|
Cu. ft. | Liters | H x W x D (mm) | H x W x D (mm) | mm | Equip | Ship | ||
PG 430/20 to 60 /RH/A | 16 | 430 | 1200x600x600 | 1795x730x1095 | 3 | 530×560 | 250 | 325 |
PG 600/20 to 60 /RH/A | 21 | 600 | 1200x700x700 | 1795x830x1195 | 3 | 630×660 | 275 | 350 |
PG 1000/20 to 60 /RH/A | 34 | 1000 | 1500x800x800 | 2095x930x1295 | 4 | 730×760 | 325 | 425 |
PG 2000/20 to 60 /RH/A | 71 | 2000 | 1500x1600x800 | 2095x1760x1295 | 8 | 710×760 | 375 | 475 |
Rain Spray System (Meet IPX3 and IPX4, 4K test) | |||
 | (IPX3,4) | (IPX4K) | |
controller | LCD Touch Screen Display And Controller | ||
Nozzle diameter | 0.4 mm | 0.8 mm | |
Nozzle distance | 50 mm | ||
Flow rate | 0.07 L/min | 0.6 L/min  +/-0.5 % | |
Arm Radius in mm | Â 200 mm | ||
Rotating angle | +/- 270,Adjustable | ||
Rotating speed | Adjustable (60 deg per sec) | ||
Rotating table | Speed Is Adjustable (option for – Both deration rotate) | ||
Plate | Adjustable Spray For Flow and Spray Time | ||
Pressure regulator | 0- 400 KPA Adjustable | ||
Interior / exterior | SS 304 / MS with Powder Coated |
Swing pipe diameter | 0.2m, 0.4m, 0.6m, 0.8m, 1.0m
(according to the size of the measured object to select the swing pipe size) |
Pendulum tube angle | 60 degrees ,vertical ± 90 and 180 degrees |
Orifice | The removable design, pinhole 0.4 mm, specially designed nozzle, spray rain water pressure 50-150kpa |
Testing temperature | Room temperature |
Specimen rotate speed | 1-3r/min (Adjustable) |
Pressure gauge | 50-150Kpa |
Oscillating angle | IPX3: spray ±60° from vertical line to each side, total 120°
IPX4: spray ±180° from vertical line to each side, total 360° |
Oscillating speed | IPX3: 2*120° for 4s
IPX4: 2*360° for 12s |
Specification | DUST-450 | DUST-1000 |
---|---|---|
Chamber volume (Litres) | 50 | 80 |
Internal Dimensions (WXDXH) (mm) |
420mmX395mmX350mm | 450mmX400mmX450mm |
Internal Dimensions (WXDXH) (mm) |
720mmX590mmX520mm | 740mmX618mmX630mm |
Temperature Range (°C) | 5°C above ambient to +80 °C | |
Temperature accuracy | +1°C | |
Display resolution | +-1°C | |
Timing range | 1~9999min | |
Shelves (Nos) | 2 | |
Power consumption | 1100W | 1550W |
Electrical requirements | 220V, 50Hz, Single phase |
Specification | HAO-100 | HAO-150 | HAO-250 |
---|---|---|---|
Test space Dimentions (WXDXH) (mm) |
450mmx 450mm x 600mm | 500mmx 500mm x 650mm | 600mmx 600mm x 750mm |
Test space Volume (L) | 100 | 150 | 250 |
Temperature Range (°C) | above ambient +40°C to +200°C |
above ambient +40°C to +200°C |
above ambient +40°C to +200°C |
Temperature Fluctuation (°C) | +1°C | ||
Electrical Supply | 1ø/N/E 230VAC +10% 50Hz | ||
Type of controller | Option PC based software for Data Logging |
Catalouge No | CRB-20LTR |
---|---|
capacity | 16 bags |
volume | 20liters |
Temperature | 4.0°C |
Accuracy | +-0.5 °C |
Input Voltage | 230v AC |
suitable Fluids | D.M.Water |
Model | bath | control | Concentric Rings | Heating |
---|---|---|---|---|
CR6 | 30*20*10 cm | Digital | 6 holes of 75 mm with steps of 25 mm | 800w*1 |
CR12 | 40*30*10 cm | Digital | 12 holes of 75 mm with steps of 25 mm | 800w*2 |
CR24 | 60*40*10 cm | Digital | 24 holes of 75 mm with steps of 25 mm | 1500w*2 |
Chamber Operation | Both the chambers are independently operable and can be synchronized for one common operation. |
Performance | To carry out steady state as well as Cyclic Temperature tests :
A. Climatic tests B. Rain test C. IR test with black body test D. Dual test |
Temperature range | -40℃~+150℃ in both chambers with 1% accuracy |
Work Space | Work room 1- Inner size 2184 Litter – 1300 mm W x 1500 mm D x 1200 mm H
Work room 2- Inner size 2184 Litter – 1300 mm W x 1500 mm D x 1200 mm H |
External dimensions | 3175 x 2375 x 2450 (WxHxD) |
Humidity | 20 – 98 % RH / ± 3 % RH limited by minimum the Climatic range of + 25 OC to +80 OC. |
Infrared Light test setup | 9 IR lamps with Irradiation Power range : 1200 W/m² to 500 W/m² in the 1300 x 700mm target area automatically controlled with the Block sensor method |
Water Spray test setup | Nozzle – 4nos (over all flow rate 30L/M)
Water temp 5 deg to ambient Spray water pressure:Â 2.9 Bar (290 Kpa) |
Control system | Siemens PLC 2 Nos with one PC & software |
Construction Features | Interior SS304 sheet thickness – (1.5mm) Stainless Steel Argon arc welded |
Chiller | 2 chiller units for condenser cooling & spray water cooling are included |
Exterior | Outer MS sheet thickness 1.5 mm with powder coated |
Insulation | 125 mm thick Puf/Glass wool insulation |
Doors | 1. Front side two number door size 1100 mm W x 1000mm H with
Viewing window 300 x 400 mm 2. Left & right side each One number Door 800 mm W x 1000 mm H |
Power source inside chamber | Aplab made Power source 60V/30A : DC power source (Adjustable) |
Temperature uniformity | ≤2℃(empty load and constant state) |
Temperature deviation | ±2℃(empty load and constant state) |
Humidity Deviation | +2~-3%(>75%RH) |
±5%(≤75%RH) | |
Heating up time | Less than 90 min(20℃  → +130℃, average rate ≥2℃ /min during the whole test, empty chamber) |
Cooling down rate | Less than 90 min(20℃  → -40℃, average rate ≥ 1℃  /min during the whole test, empty chamber) |
Water cooling time | Time for spray water cooling down: +25~+5℃  , 80L water requires 60 minutes. |
Port holes | 2 Nos. 100mm both sides |
Partition door | Partition Door Dimension 1300 mm W x 800 mm H – made with FRP material |
Silicon Gasket | Double gasket, one on the chamber and one on the door. |
Hinges & Latches | Heavy duty hinges with toggle type locking arrangement. |
Mounting | Floor mounting type with wheel. |
Noise | Max 80 dB |
Model | W-ETC |
Size | 200 to 8,000 cu. ft. (5,600 to 226,500 liters) of work space Custom Sizes Available |
Temperature Range | Single Stage: -34°C to +190°C (-30°F to +375°F) Range: -45°C to +190°C (-50°F to +375°F) II Range: -50°C to +190°C (-58°F to +375°F) Cascade: -70°C to +190°C (-94°F to +375°F) |
Optional Humidity Range | 10% to 95% RH |
Product Model | IP-X9K-500C | IP-X9K-1000C | IP-X9K-1250C |
Volume | 500 Liters | 1000 Liters | 1250 Liters |
Test Room (WxHxD) mm | 800*800*800 | 1000*1000*1000 | 1000*1250*1000 |
External Dimension (WxHxD) mm | 1300*1150*1800 | 1500*1950*1300 | 1500*1550*1950 |
Sample Test Distance | 100mm~150mm | 100mm~150mm | 200mm~400mm |
Test Sample Load Weight | 10KG~ 15 KG | 15KG~ 20 KG | 20KG~ 40 KG |
Water Pressure | 8000Kpa~10000Kpa | 8000Kpa ~10000Kpa | 80 Bar~100 Bar |
Water Spray Angle | 0°, 30°, 60°, 90° | ||
Nozzle Design | Custom SS 304 four fan nozzles made of stainless steel, located at 0°, 30°, 60°, 90° of the test platform level | ||
The distance between the nozzle and the test object is 100~150mm, and the distance between the nozzle and the test plate can be adjusted. | |||
The maximum movement distance of the nozzle is 300mm, and the Angle error is every 50mm | |||
Injection Design | Each IPX9K nozzle is equipped with high pressure and high temperature actuating solenoid valve, and the actuating time of each Angle is 10 seconds (it can be set and changed for 0-5min) | ||
The IPX9K nozzle can set the injection time and stop time, and spray in turn (0-1000 cycles can be set) | |||
Spray Nozzle | Four Units, 30 seconds each position | ||
Spray Range | 30° ± 5°(Single hole)|Space 100-150mm | ||
Water Spray Temperature | Room temp +10°C ~ 88°C (Adjustable) | ||
Hot water storage tank temperature can reach 88 ℃ (hot water injection test, high pressure hot spray) | |||
Sight Window | Equipped with 10 mm reinforced glass and explosion-proof transparent protective film, the internal lighting adopts isolated lighting | ||
Water Flow Rate | 14 L-16 L/min | ||
Testing Sample Shelf | SS 304, Speed: 5 ±1 r.p.m | ||
Shelf Height | 200-400 mm, Rotate 360 degrees horizontally | ||
Test Platform Diameters | 550 mm, 600 mm (Options) | ||
Ambient Temperature | 5 ℃ ~ + 32 ℃|Ambient humidity:≤85% | ||
Power Requirements | AC 415/N/E( ±10%)V/50HZ Three-phase Five-wire system |
TECHNICAL SPECIFICATIONS
Temperature and Humidity Test Chamber Specification
Â
Technical Description of the Infrared System
Â
Irradiation Parameter
Irradiation Spectrum:
VIS: 6 % (380 – 780 nm)
IR-A: 46 % (780 – 1.400 nm)
IR-B: 44 % (1.400 – 3.000 nm)
IR-C: 4 % (3.000 – 10.000 nm)
Irradiation Distance: approx. 600 mm from bottom lamps to target area
Irradiation Power: 1200 W/m² to 100 W/m² in the target area
Integrate the dimmer pack into your chamber controlDual Climatic test Chamber Combined with Rain and IR lamp Test
Parameter | 3-Phase | 1-Phase / 2-Phase |
---|---|---|
Rating | 3kVA to 3500kVA | 1kVA to 20kVA |
Reference Standard | IS 11171 : 1985 (Reaffirmated 2006) | |
Type of Transformer | Floor mounted, natural air-cooled /oil-cooled (depending on rating) | Dry type, floor mounted, natural air-cooled |
Configuration | Delta / star 1:1 (or as per user specification) | 1:1 (or as per user specification) |
Default Vector Group | Dyn11 | |
Type of lamination | CRNO / CRGO | |
Load Regulation | Better than 3% | |
Class of insulation | Class H | |
Efficiency | 3 – 12 kVA (>95%)> 15 kVA (>97%)At rated input voltage and at 100% rated current of loads that are linear | |
Insulation strength | Withstands 2.5 kV for 1 minute (between windings & between windings and body) | |
DC galvanic isolation | >1000 Mega Ohms – for UIT >100 Mega Ohms – for GIT | |
Common Mode noise rejection (for UIT only) | Up to 10kHz > 100 dB 10 kHz to 50 kHz > 60 dB 50 kHz to 1 MHZ > 40dB | |
Short Circuit Protection Indications | HRC fuse at input provided as a standard upto 200kVA | |
Indications | LED Lamps for Output Presence | |
Housing | Sheet metal housing provided with Input / Output terminations | |
Standards | IS 2026 Standards |
SAVE ENERGY | Track Daily Energy Consumption | Â Set Energy Targets |
Monitor Deviations | Monitor PF and load variations | |
Monitor Night time Wastages | Get Alarms for low PF | |
SAVE TIME | Receive daily Energy reports on your Mobile APP | Save engineer’s time for data collection |
IMPROVEÂ PERFORMANCE | Monitor Stabiliser Performance | Monitor Unbalances |
Get Alarms for Stabiliser TRIP | Get Alarms for Low/high voltage and overload |
Feature | 3 Phase Unbalanced Air cooled(AU/AR Models) | 3 Phase Unbalanced Oil cooled(OU/OR Models) |
---|---|---|
Rating (kVA) | 3-500 | 3-4000 (OU)/ 15-500 (OR) |
Type of cooling | Air | Oil |
Input voltage range (V L-L)* | 310-480 / 340-480 / 360-460 | |
Output voltage (V L-L)* | 415 (380V/400V – optional) | |
Output Voltage Regulation | 1% of nominal output voltage | |
Input frequency range | 47Hz — 53Hz | |
Efficiency | >97% | |
Effect of Load Power Factor | Nil | |
Waveform Distortion | Nil | |
Type of Servo Control | Micro Controller based True RMS sensing and correction | |
Servo Motor Drive | Triac based drive for AC Step Synchronous motor | |
Under/ Over Voltage cutoff * | Electronic cutoff circuit with graded time delay, set @ +5% /-10% of nominal output voltage | |
Overload cutoff | CT based Electronic cutoff circuit with graded time delay set @ 110% of rated full load current | |
Short circuit protection | MCB / MCCB provided up to 100 kVA HRC fuse provided for 125-200 kVA |
|
Single phasing prevention | Provided in AU/OU models only; Not provided in the AR/OR models | |
Phase Reversal Trip | Provided in AU/OU models only; Not provided in the AR/OR models | |
Stabiliser bypass | Provided up to 50 kVA 3-phase; Optional > 50 kVA | |
Transient Suppression | Spike Suppression through MOV is provided (Surge Arrestor is optional) | |
Emergency Off Switch | Provided in AU/OU models only; Not provided in the AR/OR models | |
Frequency cut off protection | Optional | |
Input High Voltage Trip | Optional | |
Resetting mode | Manual / Auto option provided with programmable time delay | |
Display Type | 2 Line LCD Panel | |
Parameters displayed | Input & Output Voltages (Line & Phase), Output Currents & Frequency | |
Input / Output Terminations | Bolted Terminals up to 100kVA, Busbar 125kVA and above | |
Standards | IS 9815 (Part – 1) : 1994 |
MODEL | SX-030 | SX-040 | SX-060 | SX-080 | SX-100 | SX-120 | |
---|---|---|---|---|---|---|---|
Capacity | 30kVAÂ 27kW | 40kVAÂ 36kW | 60kVAÂ 54kW | 80kVAÂ 72kW | 100kVAÂ 90kW | 120kVAÂ 108kW | |
INPUT | |||||||
Rated Voltage | 400Vac | ||||||
Voltage Range |  ± 25% | ||||||
Rated Frequency | Â 50 / 60 Hz | ||||||
Frequency Range |  50 / 60 Hz ± 5 Hz | ||||||
Bypass Voltage Range | ± 20% (settable) | ||||||
Delayed Start of Rectifier | 1 ~ 300 s (settable via display panel) | ||||||
ECO Voltage Range | ± 10% (settable) | ||||||
OUTPUT | |||||||
Voltage | 380V / 400V / 415Vac | ||||||
Voltage Regulation | ± 1% | ||||||
Frequency | Synchronized with utility in mains mode; 50 / 60 H± 0.1% in battery mode | ||||||
Waveform | Sinusoidal | ||||||
Power Factor | 0.9 | ||||||
Crest Factor | 3:1 | ||||||
Total Harmonic Distortion (THDV) | ≤2% (linear load); ≤5% (non-linear load) | ||||||
Transfer Time | AC mode to battery mode: 0ms | ||||||
Inverter mode to bypass mode: 0ms | |||||||
Inverter mode to ECO mode: 5 ~ 10ms | |||||||
Overload | 105%: long time running, 105% ~ 110% for lh, | ||||||
110% ~ 125% for 10 min, 125% ~ 150% for 1 min, 150% ~ 200% for 200ms, >200% for 100ms | |||||||
BATTERIES | |||||||
DC Voltage | 12V x configured battery number (settable via display panel) | ||||||
Number of Battery | 28~32 pcs (settable) | ||||||
Charging Current | 10A default / settable | ||||||
Charging | Three-stage charging, auto switch floating / equalizing charge | ||||||
Battery State Display | Display battery backup time, battery remaining capacity | ||||||
Battery Self-test | Settable periodic self-test; manually configurable test time and voltage | ||||||
SYSTEM | |||||||
Efficiency | Online mode:upto 93%; ECO mode:98%≥ | ||||||
Parallel Numbers | max6 | ||||||
Protections | Short-Circuit, Overload, Over-voltage, Under-voltage, Low Battery, Over-temperature, Fan fault | ||||||
Communications | RS232 / RS485 / Dry Contacts (standard), SNMP (optional) | ||||||
IP Rating | IP20 | ||||||
EMI | EN62040-2 | ||||||
EMS | IEC61000-4-2(ESD), IEC61000-4-3(RS), IEC61000-4-4(EFT), IEC61000-4-5(surge) | ||||||
OTHERS | SX-030 | SX-040 | SX-060 | SX-080 | SX-100 | SX-120 | |
Humidity | 0 ~ 95% RH @ 0 ~ 40°C (non-condensing) | ||||||
Noise Level | 55dB | 60dB | 85dB | ||||
Dimensions (W x D x H) (mm) | 400 x 800 x 1100 | 600x700x1500 | 700 x 800 x 1700 | ||||
Packaged Dimensions (W x D x H) (mm) | 490 x 920 x 1250 | 700x800x1850 | 800 x 900 x 1850 | ||||
Net /Gross Weight (kg) | 210/252 | 260/302 | 460/480 | 590/620 | 630/660 | 690/720 |
MODEL | HX-80 | HX-100 | HX-120 | HX-160 | HX-200 | HX-250 | HX-300 | ||
---|---|---|---|---|---|---|---|---|---|
Capacity | 80kVA | 100kVA | 120kVA | 160kVA | 200kVA | 250kVA | 300kVA | ||
72kW | 90kW | 108kW | 144kW | 180kW | 225kW | 270kW | |||
INPUT | |||||||||
Rated Voltage | 400Vac | ||||||||
Voltage Range | 346V to 456V (full load)Â 304V to 346V (power derating 10%) | ||||||||
Rated Frequency | 50 / 60 Hz | ||||||||
Frequency Range | 50 / 60 Hz ± 5Hz | ||||||||
Power Factor | ≥0.99 | ||||||||
Total Harmonic Distortion (THDI) | ≤3% | ||||||||
Input Current-limiting | 1.1 times of rated current (0.1 ~ 1.1 settable) | ||||||||
Rectifier delay start | 10 s (1 ~ 300 settable) | ||||||||
Bypass Voltage Range | ± 20% (settable) | ||||||||
OUTPUT | |||||||||
Rated Voltage | 380V / 400V / 415 Vac | ||||||||
Voltage Regulation | ± 1% | ||||||||
Frequency | Synchronized with utility in mains mode; 50 / 60 Hz± 0.1% in battery | ||||||||
Waveform | Sinusoidal | ||||||||
Crest Factor | 3 : 1 | ||||||||
Total Harmonic Distortion (THDV) | ≤ 2% (linear load); ≥ 5% (non-linear load) | ||||||||
Transfer Time | 0 ms | ||||||||
Inverter Overload Capability | 105% ~ 110% for 60 min; | ||||||||
110% ~ 125% for 10 min | |||||||||
BATTERIES | |||||||||
DC Voltage | 600 Vdc (supports 576 Vdc / 588 Vdc / 612 Vdc / 624 Vdc) | ||||||||
Number of Battery | 50 pcs (supports 48 / 49 / 51 / 52 pcs) | ||||||||
Charging Current | Charging rate (settable) x battery capacity (settable) x number of battery group (settable) | ||||||||
Battery State Display | Battery remaining capacity and backup time | ||||||||
Battery Self-test | Settable periodic self-test; manually configurable test time and voltage | ||||||||
SYSTEM | |||||||||
Efficiency Max. Parallel Numbers | Lien mode≥ 93%; ECO mode≥ 98% | Lien mode≥ 94%; ECO mode≥ 98% | |||||||
6 | |||||||||
Protections | Short-circuit, Overload, Over Temperature, Over Voltage, Under Voltage, Battery Low Voltage and Fan Failure | ||||||||
Communications | RS232 / RS485 / dry contacts (standard); SNMP (optional) | ||||||||
IP Rating | IP20 | ||||||||
Display | 5.7 inches LCD touch screen | ||||||||
OTHERS | HX-80 | HX-100 | HX-120 | HX-160 | HX-200 | HX-250 | HX-300 | ||
Operating Temperature | 0°C to 40°C | ||||||||
Storage Temperature | – 25°C to 55°C (without battery) | ||||||||
Humidity | 5% to 95% (non-condensing) | ||||||||
Noise Level at 1 m | < 65 dB | ||||||||
Dimensions (W x D x H) (mm) | 800 x 800x 1800 | 800 x 860 x 1700 | 1210 x 860 x 1950 | ||||||
Packaged Dimensions (W x D x H) (mm) | 900 x 900 x 2050 | 900 x 1000 x 1950 | 1300 x 1000 x 2200 | ||||||
Net / Gross Weight (kg) | 580 / 630 | 630 / 680 | 680 / 730 | 790 / 810 | 1135 /1200 | 1275 /1340 | 1355 /1420 |
Particulars | UDF 90 | UDF 185 | UDF 360 |
---|---|---|---|
Internal Volume(Liters) | 90 | 185 | 360 |
No. of trays | 2 | 3 | 6 |
No. of Internal Door | 1 | 2 | 4 |
Internal Dimension W x D x H (mm) | 400 x 400 x 580 | 510 x 510 x 730 | 700 x 510 x 1000 |
External Dimension W x D x H (mm) |
711 x 877 x 1405 | 820 x 987 x 1560 | 1010 x 987 x 1830 |
Operating Temperature Range | -45°C to -86°C | ||
Insulation (CFC free polyurethane foam) | Body : 150 mm sides, 300 mm Back, Door : 110 mm | ||
Temperature Control | Microprocessor PID controller with PT-100Â Class AÂ sensor | ||
Optional HMI Display | 7″ touch Screen | ||
Power Failure Alarm | Audio Visual Alarm | ||
Door Open Alarm | Audio Visual Alarm in case door open for over one minute | ||
Inner Body Material | S.S. 304 (AISI Grade, Non Corrosive, Non Magnetic) | ||
Outer Body Material | Powder Coated CRCA Steel | ||
Noise Level | Less Than 65 db(A) | ||
Electrical | 220-240 volts, 50 Hz, SINGLE PHASE | ||
Specification | SESS/PI-0 | SESS/PI-2 | SESS/PI-2 |
---|---|---|---|
Temperature Range (°C) | 15-35°C | ||
Temperature accuracy | ±0.1 | ||
Timer (min) | 0-999 | ||
Variation (%) | ±0.5 | ||
Power (KW) | 0.5 | 0.8 | 1.35 |
Interior Dimensions(HxWxD) (mm) | 530X390X390 | 1050X670X600 | 390X480X300 |
Overall (HxWxD) (mm) | 820X590X390 | 1500X670X600 | 680X480X300 |
Tray size (HxWxD) | 950X1090X390 | 1750X1170X600 | 390X480X300 |
Net Weight (KG) | 110 | 180 | 320 |
Catalogue No. | PTB-20 | R-PTB-20 |
Capacity | 16 bags | 16 bags |
Volume | 20 liters | 20 liters |
Temperature | 37 ºC | 4.0 ºC |
Accuracy | ± 0.2 ºC | ± 0.2 ºC |
Input Voltage | 230 V AC | 230 V AC |
Suitable Fluids | D.M water | D.M water |
Specification | DUST-450 | DUST-1000 |
---|---|---|
Chamber volume (Litres) | 50 | 80 |
Internal Dimensions (WXDXH) (mm) |
420mmX395mmX350mm | 450mmX400mmX450mm |
Internal Dimensions (WXDXH) (mm) |
720mmX590mmX520mm | 740mmX618mmX630mm |
Temperature Range (°C) | 5°C above ambient to +80 °C | |
Temperature accuracy | +1°C | |
Display resolution | +-1°C | |
Timing range | 1~9999min | |
Shelves (Nos) | 2 | |
Power consumption | 1100W | 1550W |
Electrical requirements | 220V, 50Hz, Single phase |
Model | Internal | Dimensions in cms | Max No. of Trays | |||||
---|---|---|---|---|---|---|---|---|
(S)OR(G) | Cu.Ft/Ltrs. | Internal | External | |||||
W | D | H | W | D | H | |||
BOD 90 S/G | 3/90 | 45 | 40 | 50 | 60 | 82 | 104 | 3 |
BOD 200/G | 8/200 | 60 | 63 | 60 | 75 | 106.5 | 117 | 4 |
BOD 325/G | 12/325 | 60 | 60 | 90 | 75 | 106.5 | 147 | 6 |
BOD 400 S/G | 16/400 | 60 | 63 | 106 | 75 | 106.5 | 163 | 7 |
BOD 600 S/G | 22/600 | 80 | 80 | 95 | 95 | 126.5 | 154 | 6 |
BOD 800 S/G | 28/800 | 80 | 80 | 125 | 95 | 126.5 | 187 | 9 |
BOD 1000 S/G | 32/1000 | 80 | 8 | 157 | 95 | 126.5 | 219 | 11 |
Model No | BBR 60 ltr | BBR 150 ltr | BBR 300 ltr |
---|---|---|---|
capacity(no of bags) | 60 | 160 | 300 |
Trays | 2 | 4 | 4 |
Inner Dimensions(mm) | 400(w)*430(d)*810(h) | 555(w)*430(d)*1310(h) | 700(w)*520(d)*1310(h) |
voltage | 230VAC/50HZ | 230VAC/50HZ | 230VAC/50HZ |
Name Of The Requirement | Micro Controller Based Blood Bank Refigirator |
---|---|
Control System | Micro controller based temperature indicator cum controller with digitsl display and PT 100 sensor |
Alarm | Audio visual alarm if the temperature deviates from the present temperature |
Refrigeration System | Hermitically sealed Cfc free emerson/damfose compressor with R 134 a refrigerant |
Air Curculation | Motor and blower arrangement to have uniformity temoerature under loaded temperature |
Insulation | 100 MM thick CFC free PUF insulation |
Lighting | Interior illumination for Working area |
Observation Code | Inside see through unbreakable acrylic door |
Trays | specially degigned for stainless steel baskets |
others | castrol wheels MCB,Heavy duty latch with lock and key |
power | works on 230 v AC single phase 50HZ |
Temperature Recorder | 7 days circular chat G-tek |
safety features | 180 sec compressor ‘on’ delay timer to safe guard the compressor |
Technical Data | ||
Model No. | DFV – 245 | DFV – 340 |
---|---|---|
Capacity (Liters) | 245 | 340 |
Temperature Range °C | -16 ° C -24 ° C | |
Door | 1 | 1 |
Baskets / Shelves | 6 | 7 |
External Dimensions (mm) | ||
Width | 533 | 610 |
Depth | 610 | 635 |
Height | 1448 | 1854 |
Technical Data | ||
Model No. | UTC – 265 | UTC – 400 |
---|---|---|
No. of Doors | 2 | 3 |
Capacity (Litters) | 265 | 400 |
Temperature Range °C | -10 to -20 | -10 to -20 |
Fully Automatic Controller with Temp. Display | LED | LED |
Ext. Dimension (W x D x H) in mm | 1360 x 700 x 860 | 1795 x 700 x 860 |
Int. Dimension (W x D x H)in mm | 795 x 580 x 560 | 1230 x 580 x 560 |
Specification | ETC-275 | ETC-480 | ETC-800 | ETC-1200 |
---|---|---|---|---|
Effective capacity L | 275 | 480 | 800 | 1200 |
Temperature range@20°C | +5~+65 | +5~+65 | +5~+65 | +5~+65 |
Temperature stability±°C | 0.1~0.2 | 0.1~0.2 | 0.1~0.2 | 0.1~0.2 |
Temperature deviation °C | 1.0 | 1.0 | 1.0 | 1.0 |
Humidity range(std)opt) | 40~95%RH | 40~95%RH | 40~95%RH | 40~95%RH |
Humidity range(opt) %RH | 20~95 | 20~95 | 20~95 | 20~95 |
Humidity stability ±%RH | 1-2 | 1-2 | 1-2 | 1-2 |
Humidity deviation %RH | 3-5 | 3-5 | 3-5 | 3-5 |
Heater wattage W | 450 | 450 | 950 | 950 |
Cooling capacity@20°C W | 250 | 350 | 500 | 800 |
Interior size(WDH) mm | 535×480×950 | 635×560×1350 | 935×640×1350 | 1235×720×1350 |
Overall size(WDH)mm | 640×660×1600 | 740×740×1972 | 1040×820×1972 | 1340×900×1972 |
Air movement | Horizontal | Horizontal | Horizontal | Horizontal |
Shelves (standard/maximum) | 2/5 | 3/7 | 3/7 | 3/7 |
Specification | Vibro-ETC 400 Vibro-ETC 400C |
Vibro-ETC 600 Vibro-ETC 600C |
Vibro-ETC 1200 Vibro-ETC 1200C |
Vibro-ETC 2200 Vibro-ETC 2200C |
---|---|---|---|---|
Useful area capacity (I) | 400 | 600 | 1200 | 2200 |
Internal dimensions approx. (mm) WIDTH x DEPTH x HEIGHT |
700 x 700 x 800 | 850 x 750 x 950 | 1000 x 1150 x 1080 | 1350 x 1350 x 1200 |
Distance between the bottom of the test space and the floor (mm) |
650….1400 | 650….1400 | 700….1400 | 700….1400 |
Temperature Range (°C) TC _ _ _ _ ETC _ _ _ _ C fluctuation |
-40 to 180°C -70 to 180°C ±1…±1.5 |
-40 to 180°C -70 to 180°C ±1…±1.5 |
-40 to 180°C -70 to 180°C ±1…±1.5 |
-40 to 180°C -70 to 180°C ±1…±1.5 |
Temp. changing rate Heating | 5 | 5 | 5 | 5 |
Temp. changing rate Cooling | 5 | 5 | 5 | 5 |
Humidity range (%) (t= 25/+80°C) fluctuation |
10 to 98% ±3…±5 |
10 to 98% ±3…±5 |
10 to 98% ±3…±5 |
10 to 98% ±3…±5 |
Temp. range for climatic test corrector |
20 to 85°C | 20 to 85°C | 20 to 85°C | 20 to 85°C |
Supply voltage (Vac) | 410V ±10%/50Hz/3 + N + G |
Specification | TS 25L-B2 | TS 64L-B2 | TS 120L-B2 |
---|---|---|---|
Test Basket Zone (W x D x H) in mm | 250 x 250 x 400 | 400 x 400 x 450 | 500 x 500 x 400 |
Test Space Dimension (W XD X H) in mm | 400 x 400 x 450 | 550 x 550 x 450 | 700 x 700 x 450 |
External Dimension (W x D x H) in mm | 900 x 1860 x 2450 | 1200 x 2150 x 2450 | 1350 x 2300 x 2450 |
Hot Zone (°C) | 50 to 200 | 50 to 200 | 50 to 200 |
Cold Zone (°C) | -70 to 40 | -70 to 40 | -70 to 40 |
Basket Transition Time (Sec) | < 10 | < 10 | < 10 |
Recovery Time (Min) | < 5….15 | < 5….15 | < 5….15 |
Basket Movement | Vertical | Vertical | Vertical |
Type of Controller | Watlow / Siemens PLC/ HMI – SESS Climatic |
Watlow / Siemens PLC/ HMI – SESS Climatic |
Watlow / Siemens PLC/ HMI – SESS Climatic |
Model Number | Interior Dimensions (W x D x H) |
Interior Volume | Temperature Range | Humidity Control | Notes |
---|---|---|---|---|---|
TENSIL 9.7 /-35/RH | 12~15″ x  16~28″ x  15~40″ | 1.7 to 9.7 cu. ft. | -35 to 150°C | Yes | These chambers are customized to fit your testing equipment |
TENSIL 9.7 /-35/XX | 12~15″ x  16~28″ x  15~40″ | 1.7 to 9.7 cu. ft. | -35 to 150°C | No | These chambers are customized to fit your testing equipment |
TENSIL 9.7 /-60/RH | 12~15″ x  16~28″ x  15~40″ | 1.7 to 9.7 cu. ft. | -60 to 150°C | Yes | These chambers are customized to fit your testing equipment |
TENSIL 9.7 /-60/XX | 12~15″ x  16~28″ x  15~40″ | 1.7 to 9.7 cu. ft. | -60 to 150°C | No | These chambers are customized to fit your testing equipment |
Parameters:Â
Model | Temp. Range ( °C) | Temp. Accuracy (°C) | Tank Capacity (L) | Flow Rate (L/min) | Pressure (bar) | Cooling/heating power (W) | Tank Depth (mm) | Tank opening size (W*D mm) | Dimensions (W*D*H mm) | Weight (kg) |
RB201 | +5 ~ +95 | ±1 | 12 |
5~10 |
150 | 150×300 | 365×340×340 | 17 | ||
RB101 | -15 ~ +95 | ±1 | 6 | 5~10 | 0.25 | 200 | 150 | 145×130 | 420×405×400 | 25 |
RB105 | -10 ~ 95°C | ±1 | 5 | 5~10 | 0.25 | 200 | 150 | 145×150 | 215×405×550 | 26 |
RB205 | -20 ~ 95°C | ±0.5 | 5 | 5~10 | 0.25 | 200 | 150 | 140×145 | 210×405×560 | 30 |
RB305 | -30 ~ 95°C | ±0.5 | 5 | 5~10 | 0.25 | 200 | 150 | 140×145 | 215×405×560 | 33 |
RB405 | -40 ~ 95°C | ±0.2 | 5 | 5~10 | 0.25 | 200 | 150 | 140×145 | 215×405×560 | 33 |
RB2012 | -20 ~ 95°C | ±0.2 | 12 | 5~10 | 0.25 | 550 | 200 | 170×170 | 280×480×725 | 42 |
RB4012 | -40 ~ 95°C | ±0.1 | 12 | 5~10 | 0.25 | 550 | 200 | 170×170 | 280×480×725 | 45 |
RB012 | +5 ~ 99 °C | ±0.05 | 12 | 5~10 | 0.25 bar | 800 | 150 | 150×300 | 365×340×340 | 17 |
RB025 | +5 ~ 99 °C | ±0.05 | 25 | 5~10 | 0.25 bar | 1500 | 200 | 300×300 | 560×350×400 | 22 |
Specification | DUST-450 | DUST-1000 |
---|---|---|
Work Space Volume (L) (MM) | 450 | 1000 |
Test space Dimensions (WXDXH) (mm) |
750mmX750mmX750mm | 1000mmX1000mmX1000mm |
Temperature Range (°C) | 5°C above ambient to +80 °C | |
Temperature Fluctuation | ±1°C | |
Electrical Supply | 3ø/N/E 415VAC +10% 50Hz | |
Type of controller | PLC based control system |
Specification | ETC 1000 / -40 to 150 °c |
---|---|
Power of single channel | 50W/CH |
Quantity of load channels | 110CH |
Scope of load voltage | 2-100V |
Scope of load current | 0.2-5A/CH |
Load precision | ±(1%+0.1%FS) |
Qty of Layer | Six – Layer |
Height (mm) | 1300 |
Width (mm) | 1300 |
Load Model | Energy Saving |
Load mode | Constant voltage load mode + constant current load mode, CC+CV Mode |
Control system | Temperature / Humidity control type of PLC with PC software |
Temperature range | Temperature -40°C to 150°C |
Humidity Range | 10 to 98% |
Charger power socket | Universal type Power socket |
Structure material of trolley | Outer MS with Powder coated / Inner SS304 |
Mode of main control | Monitoring software for burn-in of computer-monitoring type power |
Input mode of UUT | Multi-purpose socket/speaker wire clip/custom design |
Interface mode of UUT | Connecting fixture boards (with various specifications) for first choice/custom design |
External dimension (L*W*H) | 1540 x 1668 x 1940 |
Chamber Body Material |
Model | Internal size (MM) | Pow | Voltage | Optional Refrigeration System |
---|---|---|---|---|---|
W D H H* KW | V/HZ** | ||||
FRP | SST 200 | 600 500 750 3.5 | 3.5 | 3.5 230/50/1+G | |
FRP | SST 600 | 900 640 810 1100 | 4.5 | 230/50/1+G | Yes |
FRP | SST 1200 | 1700 640 810 1100 | 5.5 | 230/50/1+G | Yes |
Inner FRP / Outer SS316 | SST 2300 | 2000 1000 1000 1300 | 7.5 | 415/50/3/N+G | Yes |
Chamber Model | Unit | TC/ETC 50 C | TC/ETC 100 C | TC/ETC 250 C | TC/ETC 550 C | TC/ETC 1000 C |
---|---|---|---|---|---|---|
Useful Internal capacity available |
Litres | 50 | 100 | 250 | 550 | 1000 |
Internal Dimension Approx in mm |
Width x Depth x Height |
400 x 300 x 500 | 500 x 400 x 600 | 600 x 600 x 750 | 850 x 7730 x 900 | 1000 x 1000 x 1000 |
Temperature range °C IEC 60068-3-5 and IEC 60068-3-6 |
TC ### | -35 to 180 °C | -35 to 180 °C | -35 to 180 °C | -35 to 180 °C | -35 to 180 °C |
ETC ### C | -70 to 180 °C | -70 to 180 °C | -70 to 180 °C | -70 to 180 °C | -70 to 180 °C | |
Control Accuracy (±°C) | (±°C) | 0.1°C | 0.1°C | 0.1°C | 0.1°C | 0.1°C |
Cooling Ramp Rate Average (Empty chamber) |
°C/min | 3°C | 3°C | 3°C | 3°C | 3°C |
Heating Ramp Rate Average (Empty chamber) |
°C/min | 3°C | 3°C | 3°C | 3°C | 3°C |
Humidty range % | % | 20/95 % | 20/95 % | 20/95 % | 20/95 % | 20/95 % |
R.H. Fluctuation | +/- % | +/- 3 % | +/- 3 % | +/- 3 % | +/- 3 % | +/- 3 % |
Supply | 230V +6/-10% / 50Hz / 1+G |
415V +6/-10% / 50Hz / 1+G |
415V +6/-10% / 50Hz / 1+G |
415V +6/-10% / 50Hz / 1+G |
415V +6/-10% / 50Hz / 1+G |
|
Refrigerating gas | R404A/R23 | R404A/R23 | R404A/R23 | R404A/R23 | R404A/R23 | |
Max. noise level with air condenser |
78d8 (A) | 78d8 (A) | 78d8 (A) | 78d8 (A) | 78d8 (A) | |
Compressor | Hermetic | Semi Hermetic | Semi Hermetic | Semi Hermetic | Semi Hermetic | |
Control system based on customer request | Non Profile / Profile controller / PLC with HMI |
Non Profile / Profile controller / PLC with HMI |
Non Profile / Profile controller / PLC with HMI |
Non Profile / Profile controller / PLC with HMI |
Non Profile / Profile controller / PLC with HMI |
|
Front Glass window | 200mm x 300mm | 200mm x 300mm | 300mm x 500mm | 300mm x 500mm | 300mm x 600mm | |
Condenser | Air cooled /Water cooled |
Air cooled /Water cooled |
Air cooled /Water cooled |
Air cooled /Water cooled |
Air cooled /Water cooled |
MODEL | SX-030 | SX-040 | SX-060 | SX-080 | SX-100 | SX-120 | |
---|---|---|---|---|---|---|---|
Capacity | 30kVA 27kW |
40kVA 36kW |
60kVA 54kW |
80kVA 72kW |
100kVA 90kW |
120kVA 108kW |
|
INPUT | |||||||
Rated Voltage | 400Vac | ||||||
Voltage Range | ± 25% | ||||||
Rated Frequency | 50 / 60 Hz | ||||||
Frequency Range | 50 / 60 Hz± 5 Hz | ||||||
Bypass Voltage Range | ± 20% (settable) | ||||||
Delayed Start of Rectifier | 1 — 300 s (settable via display panel) | ||||||
ECO Voltage Range | ± 10% (settable) | ||||||
OUTPUT | |||||||
Voltage | 380V / 400V / 415Vac | ||||||
Voltage Regulation | ± 1% | ||||||
Frequency | Synchronized with utility in mains mode; 50 / 60 H± 0.1% in battery mode | ||||||
Waveform | Sinusoidal | ||||||
Power Factor | 0.9 | ||||||
Crest Factor | 3:1 | ||||||
Total Harmonic Distortion (THDV) | <_2% (linear load); <_5% (non-linear load) | ||||||
Transfer Time | AC mode to battery mode: Oms | ||||||
Inverter mode to bypass mode: Oms | |||||||
Inverter mode to ECO mode: 5 — 10ms | |||||||
Overload | 105%: long time running, 105%— 110% for lh, | ||||||
110% — 125% for 10 min, 125% — 150% for 1 min, 150% — 200% for 200ms, >200% for 100ms | |||||||
BATTERIES | |||||||
DC Voltage | 12V x configured battery number (settable via display panel) | ||||||
Number of Battery | 28 ~ 32 pcs (settable) | ||||||
Charging Current | 10A default / settable | ||||||
Charging | Three-stage charging, auto switch floating / equalizing charge | ||||||
Battery State Display | Display battery backup time, battery remaining capacity | ||||||
Battery Self-test | Settable periodic self-test; manually configurable test time and voltage | ||||||
SYSTEM | |||||||
Efficiency | Online mode:upto 93%; ECO mode:98% | ||||||
Parallel Numbers | Max 6 | ||||||
Protections | Short-Circuit, Overload, Over-voltage, Under-voltage, Low Battery, Over-temperature, Fan fault | ||||||
Communications | RS232 / RS485 / Dry Contacts (standard), SNMP (optional) | ||||||
IP Rating | IP20 | ||||||
EMI | EN62040-2 | ||||||
EMS | IEC61000-4-2(ESD), IEC61000-4-3(RS), IEC61000-4-4(EFT), IEC61000-4-5(surge) | ||||||
OTHERS | SX-030 | SX-040 | SX-060 | SX-080 | SX-100 | SX-120 | |
Humidity | 0 ~ 95% RH @ 0 ~ 40°C (non-condensing) | ||||||
Noise Level | 55dB | 60dB | 85dB | ||||
Dimensions (W x D x H) (mm) | 400 x 800 x 1100 | 600x700x1500 | 700 x 800 x 1700 | ||||
Packaged Dimensions (W x D x H) (mm) | 490 x 920 x 1250 | 700x800x1850 | 800 x 900 x 1850 | ||||
Net / Gross Weight (kg) | 210/252 | 260/302 | 460/480 | 590/620 | 630/660 | 690/720 |