New Project Done At DRDL Hyderabad – Thermal Cyclic test chamber

Thermal Cyclic test chamber 

Environmental stress screening test  60 deg c per mint heating and cooling for missile

 

v Performance :  To carry out steady state as well as Thermal Cyclic Temperature tests.
v Work Space : Inner size 2700 Litter –  1000 mm W x  1000 mm D x 2700 mm H
v Outer Space : outer Size approximately : 1650 mm W x  1500 mm D x 3450mm H
v Temperature Range : – 70°C to 150 °C / ± 2 °C
v Controller System : Watlow (Or) Eurotherm  Controller Single Loop Profile Controller + All One PC  Make HP/Dell
v PC software : Test Profile Software – Lab View based

: Data logging software Make Eurotherm

v Cooling ramp rate :  60 deg C/min (Empty chamber) as per IEC 60068-3-5. Averaged between 180 deg C to -70 deg C with sensor in discharge of air of blower.
v Heating ramp rate :  60 deg C/min (Empty chamber) as per IEC 60068-3-5. Averaged between -70 deg C to 180 deg C with sensor in discharge of air of blower.